Adsorptive stripping differential pulse voltammetric determination of mebendazole at a graphene nanosheets and carbon nanospheres/chitosan modified glassy carbon electrode

被引:38
|
作者
Ghalkhani, Masoumeh [1 ]
Shahrokhian, Saeed [2 ,3 ]
机构
[1] Shahid Rajaee Teacher Training Univ, Dept Chem, Fac Sci, Tehran, Iran
[2] Sharif Univ Technol, Dept Chem, Tehran 111559516, Iran
[3] Sharif Univ Technol, Inst Nanosci & Technol, Tehran 111559516, Iran
关键词
Mebendazole; Graphene; Carbon nanospheres; Chitosan; Modified electrode; LIQUID-CHROMATOGRAPHY; BENZIMIDAZOLE RESIDUES; MASS-SPECTROMETRY; HYDROGEN-PEROXIDE; METABOLITES; REDUCTION; MUSCLE; DRUGS; OXIDE;
D O I
10.1016/j.snb.2013.05.054
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the first time graphene nanosheets and carbon nanospheres/chitosan (GNS-CNS/CS) based nanocomposite film modified electrode was used for the electro-oxidation of mebendazole (MD). MD is a benzimidazole drug that is used to treat human infections caused by parasitic worms. MD causes slow immobilization and death of the worms by selectively and irreversibly blocking uptake of glucose. The electrochemical behavior of MD at GNS-CNS/CS modified glassy carbon electrode has been investigated using cyclic and differential pulse voltammetry in aqueous media at different pHs. The prepared electrode showed an excellent electrochemical activity toward the electro-oxidation of MD leading to a significant improvement in sensitivity as compared to the bare glassy carbon electrode. The adsorptive stripping differential pulse voltammetry was used as an efficient method for the electroanalytical determination of MD. Under the optimal conditions, the modified electrode showed a wide linear response to the concentration of MD in the range of 0.02-1 mu M with a low detection limit (10.5 nM). (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:669 / 674
页数:6
相关论文
共 50 条
  • [41] ANODIC DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF ESTROGENS ON A GLASSY-CARBON ELECTRODE
    DENG, JQ
    ZHANG, Z
    ACTA CHIMICA SINICA, 1984, 42 (12) : 1262 - 1265
  • [42] Differential pulse voltammetric determination of the dopaminergic agonist bromocriptine at glassy carbon electrode
    Radi, A
    El-Shahawi, MS
    Elmogy, T
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (01) : 195 - 198
  • [43] DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF TRACE SILICON AT A GLASSY-CARBON ELECTRODE
    WANG, EK
    WANG, MX
    ANALYTICA CHIMICA ACTA, 1982, 144 (DEC) : 147 - 153
  • [44] Adsorptive stripping voltammetric detection of single-stranded DNA at electrochemically modified glassy carbon electrode
    Wang, HS
    Ju, HX
    Chen, HY
    ELECTROANALYSIS, 2002, 14 (23) : 1615 - 1620
  • [45] Highly Selective Differential Pulse Voltammetric Determination of Uric Acid using Modified Glassy Carbon Electrode
    Movlaee, Kaveh
    Norouzi, Parviz
    Beitollahi, Hadi
    Rezapour, Morteza
    Larijani, Bagher
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (04): : 3241 - 3251
  • [46] Differential pulse voltammetric determination of hexavalent chromium using nickel hexacyanoferrate modified glassy carbon electrode
    Dinbore, Wendimagegn T.
    Dabbo, Wolde C.
    Washe, Aemayehu P.
    SUSTAINABLE ENVIRONMENT, 2021, 7 (01):
  • [47] Graphene nanocomposite modified glassy carbon electrode for voltammetric determination of the antipsychotic quetiapine
    Biljana Nigović
    Ana Mornar
    Miranda Sertić
    Microchimica Acta, 2016, 183 : 1459 - 1467
  • [48] Graphene nanocomposite modified glassy carbon electrode for voltammetric determination of the antipsychotic quetiapine
    Nigovic, Biljana
    Mornar, Ana
    Sertic, Miranda
    MICROCHIMICA ACTA, 2016, 183 (04) : 1459 - 1467
  • [49] Mercury Thin Film at Glassy Carbon Electrode for Adsorptive Stripping Voltammetric Determination of Captopril in Pharmaceutical Samples
    Zargar, Behrooz
    Parham, Hooshang
    Hatamie, Amir
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2015, 7 (03): : 344 - 357
  • [50] Adsorption studies of trifluralin on chitosan and its voltammetric determination on a modified chitosan glassy carbon electrode
    dos Santos Melo, Acacia Maria
    Valentim, Iara Barros
    Goulart, Marilia O. F.
    de Abreu, Fabiane Caxico
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2008, 19 (04) : 704 - 710