Scanning electron microscopy (SEM) investigation of selected desensitizing agents in the dentine disc model

被引:1
|
作者
Gillam, DG [1 ]
Khan, N [1 ]
Mordan, NJ [1 ]
Barber, PM [1 ]
机构
[1] Univ London, Eastman Dent Inst Oral Hlth Care Sci, Dept Periodontol, London WC1X 8LD, England
来源
ENDODONTICS & DENTAL TRAUMATOLOGY | 1999年 / 15卷 / 05期
关键词
dentine sensitivity; dentine tubule occlusion; desensitizing agents;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Dentine sensitivity is a painful clinical condition that call affect up to 35% of the population at ally one time. Both professionally available (in-office) or commercially available (over-the-counter) products have been used to treat dentine sensitivity. The aim of the present study was to investigate whether selected in-office desensitizing agents occluded dentine tubules in the dentine disc model. Both surface effects and tubule penetration of the five selected test products were examined by scanning electron microscopy. The results of the present study appeared to demonstrate that all of the applied desensitizing agents produced some occlusion of the tubules although the level of coverage and occlusion varied between the products. Of all the agents tested, ferric oxalate, the active ingredient of Sensodyne Sealant, produced crystal-like structures which occluded a higher proportion of the tubules across the dentine disc surface. ALL-BOND 2 and One-Step (both light-cured primer systems) produced similar crystal-like structures and, although coverage was not uniform across the disc surface, there was some reduction in tubule diameter. These three products, however, appeared to be more effective than either Butler Protect (potassium oxalate) or Oxa-gel (potassium oxalate in a gel) where there was a marked decrease in both the level of coverage and tubule occlusion. Both quantitative and functional studies are required in order to determine the effects of these agents on dentine permeability (fluid flow) as well as clinical studies to determine their effectiveness over time in reducing pain arising from dentine sensitivity.
引用
收藏
页码:198 / 204
页数:7
相关论文
共 50 条
  • [41] Cryo-Scanning Electron Microscopy (SEM) and Scanning Transmission Electron Microscopy (STEM)-in-SEM for Bio- and Organo-Mineral Interface Characterization in the Environment
    Wille, Guillaume
    Hellal, Jennifer
    Ollivier, Patrick
    Richard, Annie
    Burel, Agnes
    Jolly, Louis
    Crampon, Marc
    Michel, Caroline
    MICROSCOPY AND MICROANALYSIS, 2017, 23 (06) : 1159 - 1172
  • [42] SCANNING-BEAM ELECTRON MICROSCOPY OF SELECTED MICROORGANISMS
    KLAINER, AS
    BETSCH, CJ
    JOURNAL OF INFECTIOUS DISEASES, 1970, 121 (03): : 339 - &
  • [43] Characterization of polymeric membranes by means of scanning force microscopy (SFM) in comparison to results of scanning electron microscopy (SEM)
    Kamusewitz, H
    SchossigTiedemann, M
    Keller, M
    Paul, D
    SURFACE SCIENCE, 1997, 377 (1-3) : 1076 - 1081
  • [44] Investigation of plaque formation by scanning electron microscopy
    Koparal, Ece
    Tutuncu, Rengin
    Turkish Journal of Medical Sciences, 2000, 30 (02) : 119 - 124
  • [45] Model Validation for Scanning Electron Microscopy
    Ridzel, O. Yu.
    Yamane, W.
    Mansaray, I.
    Villarrubia, J. S.
    METROLOGY, INSPECTION, AND PROCESS CONTROL XXXVII, 2023, 12496
  • [46] SCANNING ELECTRON-MICROSCOPY [SEM] FOR THE DETECTION OF JEJUNAL BACTERIAL OVERGROWTH
    SUHR, O
    DANIELSSON, A
    HORSTEDT, P
    NYHLIN, H
    STEEN, L
    STENLING, R
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1987, 22 : 50 - 50
  • [47] SCANNING ELECTRON-MICROSCOPY (SEM) OF CRANIAL NEURAL CREST MIGRATION
    STEFFEK, AJ
    MUJWID, DK
    JOHNSTON, MC
    JOURNAL OF DENTAL RESEARCH, 1975, 54 : 165 - 165
  • [48] SCANNING ELECTRON-MICROSCOPY (SEM) OF ALCOHOL-FIXED SPECIMENS
    BECKER, SN
    WONG, JY
    MARCHIONDO, AA
    DAVIS, CP
    ACTA CYTOLOGICA, 1980, 24 (01) : 64 - 65
  • [49] SCANNING ELECTRON-MICROSCOPY (SEM) STUDIES OF THE SPLEEN - NORMAL AND PATHOLOGICAL
    FUJITA, T
    KASHIMURA, M
    ADACHI, K
    SCANNING ELECTRON MICROSCOPY, 1982, : 435 - 444
  • [50] SCANNING ELECTRON-MICROSCOPY (SEM) OF DENTIN SCLEROSIS IN A COMPOUND ODONTOMA
    POUEZAT, JA
    DUROSELLE, P
    JOURNAL OF DENTAL RESEARCH, 1984, 63 (04) : 544 - 544