Scanning electron microscopy (SEM) investigation of selected desensitizing agents in the dentine disc model

被引:1
|
作者
Gillam, DG [1 ]
Khan, N [1 ]
Mordan, NJ [1 ]
Barber, PM [1 ]
机构
[1] Univ London, Eastman Dent Inst Oral Hlth Care Sci, Dept Periodontol, London WC1X 8LD, England
来源
ENDODONTICS & DENTAL TRAUMATOLOGY | 1999年 / 15卷 / 05期
关键词
dentine sensitivity; dentine tubule occlusion; desensitizing agents;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Dentine sensitivity is a painful clinical condition that call affect up to 35% of the population at ally one time. Both professionally available (in-office) or commercially available (over-the-counter) products have been used to treat dentine sensitivity. The aim of the present study was to investigate whether selected in-office desensitizing agents occluded dentine tubules in the dentine disc model. Both surface effects and tubule penetration of the five selected test products were examined by scanning electron microscopy. The results of the present study appeared to demonstrate that all of the applied desensitizing agents produced some occlusion of the tubules although the level of coverage and occlusion varied between the products. Of all the agents tested, ferric oxalate, the active ingredient of Sensodyne Sealant, produced crystal-like structures which occluded a higher proportion of the tubules across the dentine disc surface. ALL-BOND 2 and One-Step (both light-cured primer systems) produced similar crystal-like structures and, although coverage was not uniform across the disc surface, there was some reduction in tubule diameter. These three products, however, appeared to be more effective than either Butler Protect (potassium oxalate) or Oxa-gel (potassium oxalate in a gel) where there was a marked decrease in both the level of coverage and tubule occlusion. Both quantitative and functional studies are required in order to determine the effects of these agents on dentine permeability (fluid flow) as well as clinical studies to determine their effectiveness over time in reducing pain arising from dentine sensitivity.
引用
收藏
页码:198 / 204
页数:7
相关论文
共 50 条
  • [21] A Comparative Evaluation of the Effects of Three Remineralizing Agents on Bleached Enamel: A Scanning Electron Microscopy (SEM) Analysis
    Singh, Neha
    Ranjan, Dipshi
    Mahreen, Shazia
    Pattanaik, Ankita
    Kaur, Gurinder
    Nagpal, Ajay
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (04)
  • [22] ELECTRONIC TRAP MICROSCOPY - A NEW MODE FOR SCANNING ELECTRON-MICROSCOPY (SEM)
    FITTING, HJ
    HINGST, T
    FRANZ, R
    SCHREIBER, E
    SCANNING MICROSCOPY, 1994, 8 (02) : 165 - 174
  • [23] Scanning electron microscopy, scanning tunneling microscopy, and atomic force microscopy studies of selected videotapes
    Hammond, EC
    ATOMIC FORCE MICROSCOPY/SCANNING TUNNELING MICROSCOPY 2, 1997, : 215 - 226
  • [24] VIRUS BUDDING AS SEEN IN SCANNING ELECTRON-MICROSCOPY (SEM)
    VIRTANEN, I
    WARTIOVA.J
    LEHTONEN
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1972, 29 : 38 - &
  • [25] SCANNING ELECTRON MICROSCOPY (SEM) OF MAMMALIAN INTESTINAL-TRACT
    BURKE, JA
    HOLLAND, P
    PEDIATRIC RESEARCH, 1973, 7 (04) : 335 - 335
  • [26] SCANNING ELECTRON-MICROSCOPY (SEM) OF BARRETTS ESOPHAGEAL MUCOSA
    MANGLA, JC
    LEE, CS
    GASTROENTEROLOGY, 1979, 76 (05) : 1193 - 1193
  • [27] SCANNING ELECTRON-MICROSCOPY WITHOUT PAIN - THE ENVIRONMENTAL SEM
    SAYER, M
    NOLAN, P
    HANSSON, CM
    CANADIAN CERAMICS QUARTERLY-JOURNAL OF THE CANADIAN CERAMIC SOCIETY, 1993, 62 (02): : 104 - 105
  • [28] Bacteriological and scanning electron microscopy (SEM) analyses of pancreatic stents
    Leung, JW
    Liu, YL
    Herrera, J
    Jang, S
    Schutz, S
    GASTROINTESTINAL ENDOSCOPY, 2001, 53 (05) : AB138 - AB138
  • [29] SCANNING ELECTRON MICROSCOPY MICROPROBE ANALYSIS (SEM-MPA)
    TAYLOR, ME
    CHEMISTRY IN BRITAIN, 1975, 11 (12) : 441 - 441
  • [30] VISUALIZATION OF CELLULAR ORGANELLES BY SCANNING ELECTRON-MICROSCOPY (SEM)
    WATSON, JHL
    SWEDO, JL
    JOURNAL OF CELL BIOLOGY, 1976, 70 (02): : A17 - A17