摘要
Recently, Fourier domain optical coherence tomography (FDOCT) has attracted much attention due to the significantly improved sensitivity and imaging speed compared to time domain OCT. The large depth of focus is necessary to image a long-depth-range sample with constant transverse resolution in FDOCT where dynamic focusing is not considered. Under such imaging scheme, an axicon lens can be used instead of a conventional focusing lens in the sample arm of OCT to achieve both high lateral resolution and a long depth of focus simultaneously. hi this study, a 800 mu m diameter axicon lens was fabricated on a silica wafer. We incorporated the fabricated axicon lens into the sample ann of our FD OCT system and investigated the lateral resolution over a long depth range, compared to the same FD OCT system using a conventional lens.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Full-range parallel Fourier-domain optical coherence tomography using a spatial carrier frequency
    Huang, Bingjie
    Bu, Peng
    Wang, Xiangzhao
    Nan, Nan
    Guo, Xin
    APPLIED OPTICS, 2013, 52 (05) : 958 - 965
  • [42] Full range complex Fourier Domain Optical Coherence Tomography based on a quadrature Mach-Zehnder interferometer
    Flueraru, C.
    Mao, L.
    Sherif, S.
    Chang, S.
    2008 IEEE INTERNATIONAL WORKSHOP ON MEDICAL MEASUREMENTS AND APPLICATIONS, 2008, : 53 - 55
  • [43] Full-range Fourier-domain optical coherence tomography based on Mach-Zehnder interferometer
    Zhang, Qiukun
    Zhong, Shuncong
    Lin, Jiewen
    Chen, Weiqiang
    Luo, Manting
    Zhong, Jiangfeng
    Yu, Yingjie
    Peng, Zhike
    Cheng, Shuying
    OPTICS AND LASERS IN ENGINEERING, 2020, 124
  • [44] Extending the effective imaging range of Fourier-domain optical coherence tomography using a fiber optic switch
    Wang, Hui
    Pan, Yinsheng
    Rollins, Andrew M.
    OPTICS LETTERS, 2008, 33 (22) : 2632 - 2634
  • [45] Analysis and Digital 3D Modeling of Long-Range Fourier-Domain Optical Coherence Tomography Images of the Pediatric Subglottis
    Su, Erica
    Sharma, Giriraj K.
    Chen, Jason
    Nguyen, Tony D.
    Wang, Alex
    Hamamoto, Ashley
    Ahuja, Gurpreet S.
    Chen, Zhongping
    Wong, Brian J-F.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS X, 2014, 8926
  • [46] Noncontact common-path Fourier domain optical coherence tomography method for in vitro intraocular lens power measurement
    Huang, Yong
    Zhang, Kang
    Kang, Jin U.
    Calogero, Don
    James, Robert H.
    Ilev, Ilko K.
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (12)
  • [47] Intraocular lens power prediction in eyes with prior radial keratotomy using Fourier-domain optical coherence tomography
    Waisbren, Emily
    Wang, Li
    Tang, Maolong
    Koch, Douglas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [48] Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography
    Cui, Lele
    Li, Ming
    Shen, Meixiao
    Lu, Fan
    Wang, Jianhua
    JOURNAL OF OPHTHALMOLOGY, 2017, 2017
  • [49] In Vivo Observation of Lens Regeneration in Rat Using Ultra-Long Scan Depth Optical Coherence Tomography
    Zhou, Kai-Jing
    Li, Yi-Ni
    Huang, Fu-Rong
    Wang, Qin-Mei
    Yu, A-Yong
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (15) : 6615 - 6623
  • [50] Analysis of Deposit Depth and Morphology in Granular Corneal Dystrophy Type 2 Using Fourier Domain Optical Coherence Tomography
    Hong, Jin Pyo
    Kim, Tae-im
    Chung, Jae Lim
    Huang, David
    Cho, Hyun Soo
    Kim, Eung Kweon
    CORNEA, 2011, 30 (07) : 729 - 738