Fourier domain optical coherence tomography with an 800μm diameter axicon lens for long-depth-range probing

被引:0
|
作者
Lee, Kye-Sung [1 ]
Koehler, Chuck
Johnson, Eric G.
Rolland, Jannick P.
机构
[1] Univ Cent Florida, Coll Opt & Photon, CREOL, 4000 Cent Florida Blvd, Orlando, FL 32816 USA
关键词
Fourier-domain optical coherence tomography; optical coherence tomography; axicon lens;
D O I
10.1117/12.649173
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, Fourier domain optical coherence tomography (FDOCT) has attracted much attention due to the significantly improved sensitivity and imaging speed compared to time domain OCT. The large depth of focus is necessary to image a long-depth-range sample with constant transverse resolution in FDOCT where dynamic focusing is not considered. Under such imaging scheme, an axicon lens can be used instead of a conventional focusing lens in the sample arm of OCT to achieve both high lateral resolution and a long depth of focus simultaneously. hi this study, a 800 mu m diameter axicon lens was fabricated on a silica wafer. We incorporated the fabricated axicon lens into the sample ann of our FD OCT system and investigated the lateral resolution over a long depth range, compared to the same FD OCT system using a conventional lens.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Long-range common-path spectral domain optical coherence tomography
    Wang, Chen
    Zhang, Qiankun
    Wang, Yimin
    Zhang, Xiangyang
    Zhang, Linna
    OPTICS EXPRESS, 2019, 27 (09): : 12483 - 12490
  • [32] Long-wavelength optical coherence tomography at 1.7 μm for enhanced imaging depth
    Sharma, Utkarsh
    Chang, Ernest W.
    Yun, Seok H.
    OPTICS EXPRESS, 2008, 16 (24) : 19712 - 19723
  • [34] Full-range Fourier domain Doppler optical coherence tomography based on sinusoidal phase modulation
    Nan, Nan
    Wang, Xiangzhao
    Bu, Peng
    Li, Zhongliang
    Guo, Xin
    Chen, Yan
    Wang, Xuan
    Yuan, Fenghua
    Sasaki, Osami
    APPLIED OPTICS, 2014, 53 (12) : 2669 - 2676
  • [35] Single-shot parallel full range complex Fourier-domain optical coherence tomography
    Huang, Bingjie
    Bu, Peng
    Nan, Nan
    Wang, Xiangzhao
    9TH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE (PIBM 2010), 2011, 277
  • [36] High-sensitive full-range optical vibrometry based on Fourier-domain optical coherence tomography
    Subhash, Hrebesh M.
    Leahy, Martin
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [37] Influence and compensation of autocorrelation terms in depth-resolved spectroscopic Fourier-domain optical coherence tomography
    Steiner, Patrick
    Meier, Christoph
    Koch, Volker M.
    APPLIED OPTICS, 2010, 49 (36) : 6917 - 6923
  • [38] Air-puff induced eye retraction and crystalline lens wobbling measured with long depth range swept source optical coherence tomography
    Jimenez-Villar, Alfonso
    Maczynska, Ewa
    Rzeszewska, Jagoda
    Wojtkowski, Maciej
    Kaluzny, Bartlomiej Jan
    Grulkowski, Ireneusz
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [39] Guiding glaucoma laser surgery using Fourier-domain optical coherence tomography at 1.3 μm
    Bayleyegn, Masreshaw D.
    Makhlouf, Houssine
    Crotti, Caroline
    Plamann, Karsten
    Dubois, Arnaud
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE III, 2012, 8427
  • [40] Simultaneous B-M-mode scanning method for real-time full-range Fourier domain optical coherence tomography
    Yasuno, Y
    Makita, S
    Endo, T
    Aoki, G
    Itoh, M
    Yatagai, T
    APPLIED OPTICS, 2006, 45 (08) : 1861 - 1865