Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?

被引:92
|
作者
Lee, Eun Jung [1 ]
Jung, Hae Kyoung [1 ]
Ko, Kyung Hee [1 ]
Lee, Jong Tae [1 ]
Yoon, Jung Hyun [1 ,2 ]
机构
[1] CHA Univ, Sch Med, Dept Radiol, CHA Bundang Med Ctr, Seongnam Si 463712, Gyeonggi Do, South Korea
[2] Yonsei Univ, Res Inst Radiol Sci, Dept Radiol, Coll Med, Seoul 120752, South Korea
关键词
Ultrasound; Elastography; Shear wave; Breast; Neoplasm; CORE-NEEDLE-BIOPSY; BI-RADS; INTEROBSERVER VARIABILITY; ULTRASOUND ELASTOGRAPHY; CLINICAL-APPLICATION; BENIGN; EXPERIENCE; LESIONS;
D O I
10.1007/s00330-013-2782-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate which shear wave elastography (SWE) parameter proves most accurate in the differential diagnosis of solid breast masses. One hundred and fifty-six breast lesions in 139 consecutive women (mean age: 43.54 +/- 9.94 years, range 21-88 years), who had been scheduled for ultrasound-guided breast biopsy, were included. Conventional ultrasound and SWE were performed in all women before biopsy procedures. Ultrasound BI-RADS final assessment and SWE parameters were recorded. Diagnostic performance of each SWE parameter was calculated and compared with those obtained when applying cut-off values of previously published data. Performance of conventional ultrasound and ultrasound combined with each parameter was also compared. Of the 156 breast masses, 120 (76.9 %) were benign and 36 (23.1 %) malignant. Maximum stiffness (Emax) with a cut-off of 82.3 kPa had the highest area under the receiver operating characteristics curve (Az) value compared with other SWE parameters, 0.860 (sensitivity 88.9 %, specificity 77.5 %, accuracy 80.1 %). Az values of conventional ultrasound combined with each SWE parameter showed lower (but not significantly) values than with conventional ultrasound alone. Maximum stiffness (82.3 kPa) provided the best diagnostic performance. However the overall diagnostic performance of ultrasound plus SWE was not significantly better than that of conventional ultrasound alone. aEuro cent SWE offers new information over and above conventional breast ultrasound aEuro cent Various SWE parameters were explored regarding distinction between benign and malignant lesions aEuro cent An elasticity of 82.3 kPa appears optimal in differentiating solid breast masses aEuro cent However, ultrasound plus SWE was not significantly better than conventional ultrasound alone.
引用
收藏
页码:1803 / 1811
页数:9
相关论文
共 50 条
  • [41] Diagnostic Performance of Shear Wave Elastography of the Breast According to Scanning Orientation
    Kim, Solip
    Choi, SeonHyeong
    Choi, Yoonjung
    Kook, Shin-Ho
    Park, Hee Jin
    Chung, Eun Chul
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (10) : 1797 - 1804
  • [42] The role of tissue elasticity in the differential diagnosis of benign and malignant breast lesions using shear wave elastography
    Hui Yang
    Yongyuan Xu
    Yanan Zhao
    Jing Yin
    Zhiyi Chen
    Pintong Huang
    BMC Cancer, 20
  • [43] The role of tissue elasticity in the differential diagnosis of benign and malignant breast lesions using shear wave elastography
    Yang, Hui
    Xu, Yongyuan
    Zhao, Yanan
    Yin, Jing
    Chen, Zhiyi
    Huang, Pintong
    BMC CANCER, 2020, 20 (01)
  • [44] Differential Diagnosis of Parotid Gland Tumors: Role of Shear Wave Elastography
    Herman, Jan
    Sedlackova, Zuzana
    Vachutka, Jaromir
    Furst, Tomas
    Salzman, Richard
    Vomacka, Jaroslav
    Herman, Miroslav
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [45] The application of qualitative shear wave elastography in differential diagnosis of thyroid nodules
    Liu, Qian-Qi
    Yang, Zhuo-Wen
    Tian, Jie
    Xing, Ping
    Tang, Hai-Ling
    Qiu, Qian-Yi
    Wu, Chang-Jun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (04): : 3569 - 3579
  • [46] Comparison of the Diagnostic Performance of Strain Elastography and Shear Wave Elastography for the Diagnosis of Carpal Tunnel Syndrome
    Park, Eun Joo
    Hahn, Seok
    Yi, Jisook
    Shin, Kyong Jin
    Lee, Yedaun
    Lee, Ho-Joon
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (05) : 1011 - 1021
  • [47] Diagnostic value of strain elastography and shear wave elastography in differentiating benign and malignant breast lesions
    Shahzad, Rafia
    Fatima, Ismat
    Anjum, Tooba
    Shahid, Abubaker
    ANNALS OF SAUDI MEDICINE, 2022, 42 (05) : 319 - 326
  • [48] SHEAR WAVE VELOCITY MEASUREMENTS FOR DIFFERENTIAL DIAGNOSIS OF SOLID BREAST MASSES: A COMPARISON BETWEEN VIRTUAL TOUCH QUANTIFICATION AND VIRTUAL TOUCH IQ
    Tozaki, Mitsuhiro
    Saito, Masahiro
    Benson, John
    Fan, Liexiang
    Isobe, Sachiko
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (12): : 2233 - 2245
  • [49] The Value of Shear Wave Elastography in the Diagnosis of Breast Cancer Axillary Lymph Node Metastasis and Its Correlation With Molecular Classification of Breast Masses
    Luo, Changyun
    Lu, Li
    Zhang, Weifu
    Li, Xiangqi
    Zhou, Ping
    Ran, Zhangshen
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [50] Classification of breast masses on ultrasound shear wave elastography using convolutional neural networks
    Fujioka, Tomoyuki
    Katsuta, Leona
    Kubota, Kazunori
    Mori, Mio
    Kikuchi, Yuka
    Kato, Arisa
    Oda, Goshi
    Nakagawa, Tsuyoshi
    Kitazume, Yoshio
    Tateishi, Ukihide
    ULTRASONIC IMAGING, 2020, 42 (4-5) : 213 - 220