Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?

被引:92
|
作者
Lee, Eun Jung [1 ]
Jung, Hae Kyoung [1 ]
Ko, Kyung Hee [1 ]
Lee, Jong Tae [1 ]
Yoon, Jung Hyun [1 ,2 ]
机构
[1] CHA Univ, Sch Med, Dept Radiol, CHA Bundang Med Ctr, Seongnam Si 463712, Gyeonggi Do, South Korea
[2] Yonsei Univ, Res Inst Radiol Sci, Dept Radiol, Coll Med, Seoul 120752, South Korea
关键词
Ultrasound; Elastography; Shear wave; Breast; Neoplasm; CORE-NEEDLE-BIOPSY; BI-RADS; INTEROBSERVER VARIABILITY; ULTRASOUND ELASTOGRAPHY; CLINICAL-APPLICATION; BENIGN; EXPERIENCE; LESIONS;
D O I
10.1007/s00330-013-2782-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate which shear wave elastography (SWE) parameter proves most accurate in the differential diagnosis of solid breast masses. One hundred and fifty-six breast lesions in 139 consecutive women (mean age: 43.54 +/- 9.94 years, range 21-88 years), who had been scheduled for ultrasound-guided breast biopsy, were included. Conventional ultrasound and SWE were performed in all women before biopsy procedures. Ultrasound BI-RADS final assessment and SWE parameters were recorded. Diagnostic performance of each SWE parameter was calculated and compared with those obtained when applying cut-off values of previously published data. Performance of conventional ultrasound and ultrasound combined with each parameter was also compared. Of the 156 breast masses, 120 (76.9 %) were benign and 36 (23.1 %) malignant. Maximum stiffness (Emax) with a cut-off of 82.3 kPa had the highest area under the receiver operating characteristics curve (Az) value compared with other SWE parameters, 0.860 (sensitivity 88.9 %, specificity 77.5 %, accuracy 80.1 %). Az values of conventional ultrasound combined with each SWE parameter showed lower (but not significantly) values than with conventional ultrasound alone. Maximum stiffness (82.3 kPa) provided the best diagnostic performance. However the overall diagnostic performance of ultrasound plus SWE was not significantly better than that of conventional ultrasound alone. aEuro cent SWE offers new information over and above conventional breast ultrasound aEuro cent Various SWE parameters were explored regarding distinction between benign and malignant lesions aEuro cent An elasticity of 82.3 kPa appears optimal in differentiating solid breast masses aEuro cent However, ultrasound plus SWE was not significantly better than conventional ultrasound alone.
引用
收藏
页码:1803 / 1811
页数:9
相关论文
共 50 条
  • [21] The differential diagnosis of benign and malignant breast cancer using shear wave elastography (SWE)
    Wang, Baohua
    Cai, Zhenyu
    Hu, Ying
    Wang, Jing
    Chu, Yanhua
    Jiang, Tian'an
    Cheng, Jing
    Zheng, Shusen
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (17): : 7404 - 7411
  • [22] Diagnostic performances of shear-wave elastography for identification of malignant breast lesions: a meta-analysis
    Chen, Limin
    He, Jun
    Liu, Gang
    Shao, Kezhong
    Zhou, Minda
    Li, Beilei
    Chen, Xiaofei
    JAPANESE JOURNAL OF RADIOLOGY, 2014, 32 (10) : 592 - 599
  • [23] Usability of Transthoracic Shear Wave Elastography in Differentiation of Subpleural Solid Masses
    Ozgokce, Mesut
    Yavuz, Alpaslan
    Akbudak, Ibrahim
    Durmaz, Fatma
    Uney, Ibrahim
    Aydin, Yener
    Yildiz, Hanifi
    Batur, Abdussamet
    Arslan, Harun
    Dundar, Ilyas
    ULTRASOUND QUARTERLY, 2018, 34 (04) : 233 - 237
  • [24] Diagnostic performances of shear-wave elastography for identification of malignant breast lesions: a meta-analysis
    Limin Chen
    Jun He
    Gang Liu
    Kezhong Shao
    Minda Zhou
    Beilei Li
    Xiaofei Chen
    Japanese Journal of Radiology, 2014, 32 : 592 - 599
  • [25] Quantitative shear wave elastography for noninvasive assessment of solid pancreatic masses
    Xie, Juan
    Liu, Hui
    Liu, Wen-sheng
    Li, Jia-wei
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2020, 74 (02) : 179 - 187
  • [26] Shear-wave elastography in the diagnosis of solid breast masses: what leads to false-negative or false-positive results?
    Jung Hyun Yoon
    Hae Kyoung Jung
    Jong Tae Lee
    Kyung Hee Ko
    European Radiology, 2013, 23 : 2432 - 2440
  • [27] Shear-wave elastography in the diagnosis of solid breast masses: what leads to false-negative or false-positive results?
    Yoon, Jung Hyun
    Jung, Hae Kyoung
    Lee, Jong Tae
    Ko, Kyung Hee
    EUROPEAN RADIOLOGY, 2013, 23 (09) : 2432 - 2440
  • [28] Diagnostic accuracy of contrast-enhanced ultrasound synchronized with shear wave elastography in the differential diagnosis of benign and malignant breast lesions: a diagnostic test
    He, Huiling
    Wu, Xiaojin
    Jiang, Meijuan
    Xu, Zhikang
    Zhang, Xuanxuan
    Pan, Jianlian
    Fu, Xinyu
    Luo, Yunkai
    Chen, Jian
    GLAND SURGERY, 2023, : 54 - 66
  • [29] Does Shear Wave Elastography Score Over Strain Elastography in Breast Masses or Vice Versa?
    Singla, Veenu
    Prakash, Aparna
    Prabhakar, Nidhi
    Singh, Tulika
    Bal, Amanjit
    Singh, Gurpreet
    Khandelwal, Niranjan
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2020, 49 (02) : 96 - 101
  • [30] Diagnostic performance of qualitative shear-wave elastography according to different color map opacities for breast masses
    Kim, Hana
    Youk, Ji Hyun
    Gweon, Hye Mi
    Kim, Jeong-Ah
    Son, Eun Ju
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (08) : E326 - E331