Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?

被引:92
|
作者
Lee, Eun Jung [1 ]
Jung, Hae Kyoung [1 ]
Ko, Kyung Hee [1 ]
Lee, Jong Tae [1 ]
Yoon, Jung Hyun [1 ,2 ]
机构
[1] CHA Univ, Sch Med, Dept Radiol, CHA Bundang Med Ctr, Seongnam Si 463712, Gyeonggi Do, South Korea
[2] Yonsei Univ, Res Inst Radiol Sci, Dept Radiol, Coll Med, Seoul 120752, South Korea
关键词
Ultrasound; Elastography; Shear wave; Breast; Neoplasm; CORE-NEEDLE-BIOPSY; BI-RADS; INTEROBSERVER VARIABILITY; ULTRASOUND ELASTOGRAPHY; CLINICAL-APPLICATION; BENIGN; EXPERIENCE; LESIONS;
D O I
10.1007/s00330-013-2782-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate which shear wave elastography (SWE) parameter proves most accurate in the differential diagnosis of solid breast masses. One hundred and fifty-six breast lesions in 139 consecutive women (mean age: 43.54 +/- 9.94 years, range 21-88 years), who had been scheduled for ultrasound-guided breast biopsy, were included. Conventional ultrasound and SWE were performed in all women before biopsy procedures. Ultrasound BI-RADS final assessment and SWE parameters were recorded. Diagnostic performance of each SWE parameter was calculated and compared with those obtained when applying cut-off values of previously published data. Performance of conventional ultrasound and ultrasound combined with each parameter was also compared. Of the 156 breast masses, 120 (76.9 %) were benign and 36 (23.1 %) malignant. Maximum stiffness (Emax) with a cut-off of 82.3 kPa had the highest area under the receiver operating characteristics curve (Az) value compared with other SWE parameters, 0.860 (sensitivity 88.9 %, specificity 77.5 %, accuracy 80.1 %). Az values of conventional ultrasound combined with each SWE parameter showed lower (but not significantly) values than with conventional ultrasound alone. Maximum stiffness (82.3 kPa) provided the best diagnostic performance. However the overall diagnostic performance of ultrasound plus SWE was not significantly better than that of conventional ultrasound alone. aEuro cent SWE offers new information over and above conventional breast ultrasound aEuro cent Various SWE parameters were explored regarding distinction between benign and malignant lesions aEuro cent An elasticity of 82.3 kPa appears optimal in differentiating solid breast masses aEuro cent However, ultrasound plus SWE was not significantly better than conventional ultrasound alone.
引用
收藏
页码:1803 / 1811
页数:9
相关论文
共 50 条
  • [1] Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?
    Eun Jung Lee
    Hae Kyoung Jung
    Kyung Hee Ko
    Jong Tae Lee
    Jung Hyun Yoon
    European Radiology, 2013, 23 : 1803 - 1811
  • [2] Diagnostic Performance of Quantitative Shear Wave Elastography in the Evaluation of Solid Breast Masses: Determination of the Most Discriminatory Parameter
    Au, Frederick Wing-Fa
    Ghai, Sandeep
    Moshonov, Hadas
    Kahn, Harriette
    Brennan, Cressida
    Dua, Hemi
    Crystal, Pavel
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (03) : W328 - W336
  • [3] Differentiating solid breast masses: comparison of the diagnostic efficacy of shear wave elastography and magnetic resonance imaging
    Farghadani, Maryam
    Barikbin, Rozbeh
    Rezaei, Mostafa Haji
    Hekmatnia, Ali
    Aalinezhad, Marzieh
    Zare, Hosein
    DIAGNOSIS, 2021, 8 (03) : 382 - 387
  • [4] Diagnostic role of shear wave elastography for differentiating benign and malignant breast masses
    Sravani, Nichanametla
    Ramesh, Ananthakrishnan
    Sureshkumar, Sathasivam
    Vijayakumar, Chellappa
    Abdulbasith, K. M.
    Balasubramanian, Gopal
    Toi, Pampa Ch
    SA JOURNAL OF RADIOLOGY, 2020, 24 (01):
  • [5] Value of shear wave arrival time contour display in shear wave elastography for breast masses diagnosis
    Zhou, Bang-Guo
    Wang, Dan
    Ren, Wei-Wei
    Li, Xiao-Long
    He, Ya-Ping
    Liu, Bo-Ji
    Wang, Qiao
    Chen, Shi-Gao
    Alizad, Azra
    Xu, Hui-Xiong
    SCIENTIFIC REPORTS, 2017, 7
  • [6] Value of shear wave arrival time contour display in shear wave elastography for breast masses diagnosis
    Bang-Guo Zhou
    Dan Wang
    Wei-Wei Ren
    Xiao-Long Li
    Ya-Ping He
    Bo-Ji Liu
    Qiao Wang
    Shi-Gao Chen
    Azra Alizad
    Hui-Xiong Xu
    Scientific Reports, 7
  • [7] Quantitative shear wave ultrasound elastography: initial experience in solid breast masses
    Evans, Andrew
    Whelehan, Patsy
    Thomson, Kim
    McLean, Denis
    Brauer, Katrin
    Purdie, Colin
    Jordan, Lee
    Baker, Lee
    Thompson, Alastair
    BREAST CANCER RESEARCH, 2010, 12 (06)
  • [8] Quantitative shear wave ultrasound elastography: initial experience in solid breast masses
    Andrew Evans
    Patsy Whelehan
    Kim Thomson
    Denis McLean
    Katrin Brauer
    Colin Purdie
    Lee Jordan
    Lee Baker
    Alastair Thompson
    Breast Cancer Research, 12
  • [9] Performance of Shear Wave Elastography for Differentiation of Benign and Malignant Solid Breast Masses
    Li, Guiling
    Li, De-Wei
    Fang, Yu-Xiao
    Song, Yi-Jiang
    Deng, Zhu-Jun
    Gao, Jian
    Xie, Yan
    Yin, Tian-Sheng
    Ying, Li
    Tang, Kai-Fu
    PLOS ONE, 2013, 8 (10):
  • [10] Benefit of Shear-wave Elastography in the differential diagnosis of breast lesion: a diagnostic meta-analysis
    Luo, Jie
    Cao, Yong
    Nian, Weiqi
    Zeng, Xiaohua
    Zhang, Hui
    Yue, Yeli
    Yu, Feng
    MEDICAL ULTRASONOGRAPHY, 2018, 20 (01) : 43 - 49