CFD simulation and validation of wind-driven rain on a building facade with an Eulerian multiphase model

被引:101
|
作者
Kubilay, A. [1 ,2 ]
Derome, D. [1 ,2 ]
Blocken, B. [3 ]
Carmeliet, J. [1 ,2 ]
机构
[1] Swiss Fed Inst Technol ETHZ, Chair Bldg Phys, Zurich, Switzerland
[2] EMPA, Swiss Fed Labs Mat Testing & Res, Lab Bldg Technol, Dubendorf, Switzerland
[3] Eindhoven Univ Technol, NL-5600 MB Eindhoven, Netherlands
基金
瑞士国家科学基金会;
关键词
Driving rain; Wind-driven rain; Computational fluid dynamics (CFD); Eulerian multiphase model; Numerical simulation; ATMOSPHERIC BOUNDARY-LAYER; ENVIRONMENT;
D O I
10.1016/j.buildenv.2012.12.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Wind-driven rain (WDR) is one of the most important moisture sources with potential negative effects on hygrothermal performance and durability of buildings. The impact of WDR on building facades can be understood in a better way by predicting the surface wetting distribution accurately. Computational Fluid Dynamics (CFD) simulation with the Lagrangian particle tracking (LPT) method has been widely used and validated by several researchers for different isolated building configurations. In this paper, Eulerian Multiphase modeling (EM) for WDR assessment is applied and validated for a monumental tower building (St. Hubertus building in The Netherlands). The LPT and EM models show comparable results and EM is validated by comparison of the calculated catch ratio values with available experimental data on windward facade. The deviations between the experimental and the model results at low rain intensity and wind speed are attributed to the absence of turbulent dispersion in both LPT and EM models. EM has the advantages, first, of less computational complexity and faster pre-processing and post-processing in terms of raindrop trajectories and WDR catch ratios, and second, of allowing the calculation of catch ratios on all surfaces of a complex geometry over the domain at once. The user time spent for the simulation decreases by at least a factor of 10 using EM instead of LPT for a single building. Additionally, the EM is expected to provide a sound basis for future WDR studies incorporating more accurate calculation of the wind flow field, e.g. by LES and the inclusion of turbulent dispersion. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:69 / 81
页数:13
相关论文
共 50 条
  • [41] Wind-driven rain on two parallel wide buildings: Field measurements and CFD simulations
    Kubilay, A.
    Derome, D.
    Blocken, B.
    Carmeliet, J.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2015, 146 : 11 - 28
  • [42] Quantification of wind-driven rain intrusion in building-integrated photovoltaic systems
    Fedorova, Anna
    Jelle, Bjorn Peter
    Hrynyszyn, Bozena Dorota
    Geving, Stig
    SOLAR ENERGY, 2021, 230 : 376 - 389
  • [43] Overhang effect on reducing wind-driven rain for a mid-rise building
    Chiu, Vincent
    Ge, Hua
    Stathopoulos, Ted
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 2506 - 2511
  • [44] Improved assessment of wind-driven rain on building facade based on ISO standard with high-resolution on-site weather data
    Ge, Hua
    Chiu, Vincent
    Stathopoulos, Ted
    Souri, Firouzeh
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2018, 176 : 183 - 196
  • [45] Characterisation of building exposure to wind-driven rain in the UK and evaluation of current standards
    Orr, Scott Allan
    Viles, Heather
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2018, 180 : 88 - 97
  • [46] Understanding and modelling future wind-driven rain loads on building envelopes for Canada
    Dukhan, Tarek
    Sushama, Laxmi
    BUILDING AND ENVIRONMENT, 2021, 196
  • [47] Numerical simulation study on the hygrothermal performance of building exterior walls under dynamic wind-driven rain condition
    Hu, Xing
    Zhang, Huibo
    Yu, Hui
    BUILDING SIMULATION, 2024, 17 (02) : 207 - 221
  • [48] Numerical simulation study on the hygrothermal performance of building exterior walls under dynamic wind-driven rain condition
    Xing Hu
    Huibo Zhang
    Hui Yu
    Building Simulation, 2024, 17 : 207 - 221
  • [49] On the accuracy of wind-driven rain measurements on buildings
    Blocken, Bert
    Carmeliet, Jan
    BUILDING AND ENVIRONMENT, 2006, 41 (12) : 1798 - 1810
  • [50] Wind-driven rain distributions on two buildings
    Karagiozis, A
    Hadjisophocleous, G
    Cao, S
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1997, 67-8 : 559 - 572