Replacement correction factors for cylindrical ion chambers in electron beams

被引:16
|
作者
Wang, L. L. W. [1 ]
Rogers, D. W. O. [1 ]
机构
[1] Carleton Univ, Ottawa Carleton Inst Phys, Ottawa, ON K1S 5B6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
ion chamber dosimetry; replacement correction factors; electron beams; Monte Carlo; EGSnrc; fluence correction; gradient correction; MONTE-CARLO-SIMULATION; HIGH-ENERGY PHOTON; IONIZATION-CHAMBER; DOSIMETRY;
D O I
10.1118/1.3213094
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In the TG-21 dosimetry protocol, for cylindrical chambers in electron beams the replacement correction factor P(repl) (or the product p(dis)p(cav) in the IAEA's notation), was conceptually separated into two components: the gradient correction (P(gr)) accounting for the effective point of measurement and the fluence correction (P(fl)) dealing with the change in the electron fluence spectrum. At the depth of maximum dose (d(max)), P(gr) is taken as 1. There are experimental data available at d(max) for the values of P(fl) (or P(repl)). In the TG-51 dosimetry protocol, the calibration is at the reference depth d(ref)=0.6R(50)-0.1 (cm) where P(gr) is required for cylindrical chambers and P(fl) is unknown and so the measured values at d(max) are used with the corresponding mean electron energy at d(ref). Monte Carlo simulations are employed in this study to investigate the replacement correction factors for cylindrical chambers in electron beams. Methods: Using previously established Monte Carlo calculation methods, the values of P(repl) and P(fl) are calculated with high statistical precision (<0.1%) for cylindrical cavities of a variety of diameters and lengths in a water phantom irradiated by various electron beams. The values of P(gr) as defined in the TG-51 dosimetry protocol are also calculated. Results: The calculated values of the fluence correction factors P(fl) are in good agreement with the measured values when the wall correction factors are taken into account for the plane-parallel chambers used in the measurements. An empirical formula for P(fl) for cylindrical chambers at d(ref) in electron beams is derived as a function of the chamber radius and the beam quality specifier R(50). Conclusions: The mean electron energy at depth is a good beam quality specifier for P(fl). Thus TG-51's adoption of P(fl) at d(max) with the same mean electron energy for use at d(ref) is proven to be accurate. The values of P(gr) for a Farmer-type chamber as defined in the TG-51 dosimetry protocol may be wrong by 0.3% for high-energy electron beams and by more than 1% for low-energy electron beams. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3213094]
引用
收藏
页码:4600 / 4608
页数:9
相关论文
共 50 条
  • [31] Electron fluence correction factors for various materials in clinical electron beams
    Olivares, M
    DeBlois, F
    Podgorsak, EB
    Seuntjens, JP
    MEDICAL PHYSICS, 2001, 28 (08) : 1727 - 1734
  • [32] Reply to 'On the pdis correction factor for cylindrical chambers'
    Wang, Lilie L. W.
    Rogers, D. W. O.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05): : L17 - L19
  • [33] REPLACEMENT CORRECTION FACTORS FOR PHOTON AND ELECTRON DOSE MEASUREMENTS
    BJARNGARD, BE
    KASE, KR
    MEDICAL PHYSICS, 1985, 12 (06) : 785 - 787
  • [34] EXPERIMENTAL-DETERMINATION OF WALL CORRECTION FACTORS .1. CYLINDRICAL IONIZATION CHAMBERS
    WITTKAMPER, FW
    MIJNHEER, BJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (07): : 835 - 846
  • [35] Wall correction factors and angle dependence of signal currents from cylindrical ionization chambers
    Takata, N
    Kurosawa, T
    Tran, NT
    RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 743 - 744
  • [36] Addendum to the determination of recombination and polarity correction factors, kS and kP, for small cylindrical ionization chambers in pulsed filtered and unfiltered beams: PTW 31023
    Bruggmoser, Gregor
    Saum, Rainer
    Kranzer, Rafael
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (04): : 368 - 371
  • [37] Perturbation factors for cylindrical ionization chambers in proton beams. Part I: corrections for gradients
    Palmans, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14): : 3483 - 3501
  • [38] Determination of the ion recombination correction factor for intraoperative electron beams
    Besheli, Majid Ghorbanpour
    Simiantonakis, Ioannis
    Zink, Klemens
    Budach, Wilfried
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (01): : 35 - 44
  • [40] Ion-recombination correction factor k(sat) for spherical ion chambers irradiated by continuous photon beams
    Piermattei, A
    Azario, L
    Arcovito, G
    Toni, MP