Replacement correction factors for cylindrical ion chambers in electron beams

被引:16
|
作者
Wang, L. L. W. [1 ]
Rogers, D. W. O. [1 ]
机构
[1] Carleton Univ, Ottawa Carleton Inst Phys, Ottawa, ON K1S 5B6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
ion chamber dosimetry; replacement correction factors; electron beams; Monte Carlo; EGSnrc; fluence correction; gradient correction; MONTE-CARLO-SIMULATION; HIGH-ENERGY PHOTON; IONIZATION-CHAMBER; DOSIMETRY;
D O I
10.1118/1.3213094
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In the TG-21 dosimetry protocol, for cylindrical chambers in electron beams the replacement correction factor P(repl) (or the product p(dis)p(cav) in the IAEA's notation), was conceptually separated into two components: the gradient correction (P(gr)) accounting for the effective point of measurement and the fluence correction (P(fl)) dealing with the change in the electron fluence spectrum. At the depth of maximum dose (d(max)), P(gr) is taken as 1. There are experimental data available at d(max) for the values of P(fl) (or P(repl)). In the TG-51 dosimetry protocol, the calibration is at the reference depth d(ref)=0.6R(50)-0.1 (cm) where P(gr) is required for cylindrical chambers and P(fl) is unknown and so the measured values at d(max) are used with the corresponding mean electron energy at d(ref). Monte Carlo simulations are employed in this study to investigate the replacement correction factors for cylindrical chambers in electron beams. Methods: Using previously established Monte Carlo calculation methods, the values of P(repl) and P(fl) are calculated with high statistical precision (<0.1%) for cylindrical cavities of a variety of diameters and lengths in a water phantom irradiated by various electron beams. The values of P(gr) as defined in the TG-51 dosimetry protocol are also calculated. Results: The calculated values of the fluence correction factors P(fl) are in good agreement with the measured values when the wall correction factors are taken into account for the plane-parallel chambers used in the measurements. An empirical formula for P(fl) for cylindrical chambers at d(ref) in electron beams is derived as a function of the chamber radius and the beam quality specifier R(50). Conclusions: The mean electron energy at depth is a good beam quality specifier for P(fl). Thus TG-51's adoption of P(fl) at d(max) with the same mean electron energy for use at d(ref) is proven to be accurate. The values of P(gr) for a Farmer-type chamber as defined in the TG-51 dosimetry protocol may be wrong by 0.3% for high-energy electron beams and by more than 1% for low-energy electron beams. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3213094]
引用
收藏
页码:4600 / 4608
页数:9
相关论文
共 50 条
  • [21] Monte Carlo Computed KQmsr Correction Factors for Reference Dosimetry of Tomotherapy Beams for 7 Ion Chambers
    Sterpin, E.
    Mackie, R.
    Vynckier, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3598 - 3598
  • [22] Monte Carlo calculations of the replacement correction factor, Prepl, for cylindrical chamber cavities in clinical photon and electron beams
    Fujio Araki
    Radiological Physics and Technology, 2012, 5 (2) : 199 - 206
  • [23] On the pdis correction factor for cylindrical chambers
    Andreo, Pedro
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05): : L9 - L16
  • [24] Determination of the recombination correction factor kS for some specific plane-parallel and cylindrical ionization chambers in pulsed photon and electron beams
    Bruggmoser, G.
    Saum, R.
    Schmachtenberg, A.
    Schmid, F.
    Schuele, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (02): : N35 - N50
  • [25] Polarity correction factor for flattening filter free photon beams in several cylindrical ionization chambers
    Ogata T.
    Uehara K.
    Nakayama M.
    Tsudou S.
    Masutani T.
    Okayama T.
    Radiological Physics and Technology, 2016, 9 (2) : 187 - 192
  • [26] MEASUREMENT OF THE REPLACEMENT CORRECTION FACTOR FOR PARALLEL-PLATE CHAMBERS IN ELECTRON FIELDS
    REFT, CS
    KUCHNIR, FT
    MEDICAL PHYSICS, 1991, 18 (06) : 1237 - 1243
  • [27] Calculated beam quality correction factors for ionization chambers in MV photon beams
    Tikkanen, J.
    Zink, K.
    Pimpinella, M.
    Teles, P.
    Borbinha, J.
    Ojala, J.
    Siiskonen, T.
    Goma, C.
    Pinto, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (07):
  • [28] ION DISTRIBUTIONS IN PLANE AND CYLINDRICAL CHAMBERS
    ROSEN, R
    GEORGE, EP
    PHYSICS IN MEDICINE AND BIOLOGY, 1975, 20 (06): : 990 - 1002
  • [29] Monte Carlo calculation of replacement correction factors for plane-parallel chambers
    Wang, L.
    Rogers, D. W. O.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S55 - S55
  • [30] Monte Carlo calculations of the replacement correction factor, P-repl, for cylindrical chamber cavities in clinical photon and electron beams
    Araki, Fujio
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2012, 5 (02) : 199 - 206