Biomechanical assessment of a novel bone lengthening plate system - A cadaveric study

被引:0
|
作者
Jung, Tae Gon [1 ]
Suh, Seung Woo [2 ]
Lee, Sung Jae [3 ]
Kim, Bongju [4 ]
Han, Dong-Wook [1 ]
Yang, Jae Hyuk [2 ]
机构
[1] Pusan Natl Univ, Coll Nanosci & Nanotechnol, Dept Nanomed Engn, Pusan 609735, South Korea
[2] Korea Univ, Guro Hosp, Dept Orthoped, Scoliosis Res Inst, Seoul 152703, South Korea
[3] Inje Univ, Dept Biomed Engn, Gimhae Si 621749, Gyungnam, South Korea
[4] Kyoto Univ, Grad Sch Med, Ctr Innovat Immunoregulat Technol & Therapeut, Sakyo Ku, Kyoto 6068501, Japan
关键词
Femur; Biomechanical stability; Bone lengthening plate; Bone mineral density; LOCKING COMPRESSION PLATE; EXTERNAL FIXATORS; MECHANICAL PERFORMANCE; ILIZAROV TECHNIQUE; FIXATION; HYBRID; OSTEOSYNTHESIS; CORROSION; FRACTURE; COMPLICATIONS;
D O I
10.1016/j.clinbiomech.2012.11.011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Although many types of external fixators have been developed for distraction osteogenesis, all have some drawbacks. We recently developed a novel bone lengthening plate to overcome these problems. The purpose of this study is to conduct biomechanical analyses using cadavers to assess the stability of the bone lengthening plate in relation to distraction length and femoral bone mineral density. Methods: We used human cadaveric femurs (n=18) to assess the effects of distraction length and bone mineral density on the biomechanical stability of the bone lengthening plate. After establishing control (n = 6, 0 mm lengthening) and experimental groups (n = 12, 30 mm lengthening), we measured biomechanical stability (structural stiffness, ultimate load, and displacement) under a compressive load. The experimental group was subdivided into a group with normal bone mineral density (n=6) and a group with osteoporosis (n=6), and the biomechanical stability of these groups was compared. Finding: Structural stiffness differed significantly between the control (417.6 N/mm) and combined experimental groups (185.6 N/mm, p = 0.002). Ultimate load also differed significantly between the control (1327.8 N) and combined experimental (331.4 N, p = 0.002) groups. Bone mineral density was unrelated to structural stiffness (p=0.204), ultimate load (0.876), or displacement (0.344). In all cases, failure of the bone lengthening plate occurred at the longitudinal connectors, such as the connecting columns between the upper and lower plates, and the lengthening shaft of the bone lengthening plate. Interpretation: The biomechanical stability of the bone lengthening plate was affected by the lengthening length but not by bone mineral density. In addition, biomechanical stability during lengthening was most strongly influenced by the longitudinal connectors. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:232 / 238
页数:7
相关论文
共 50 条
  • [31] The biomechanical stability of a novel spacer with integrated plate in contiguous two-level and three-level ACDF models: an in vitro cadaveric study
    Clavenna, Andrew L.
    Beutler, William J.
    Gudipally, Manasa
    Moldavsky, Mark
    Khalil, Saif
    SPINE JOURNAL, 2012, 12 (02): : 157 - 163
  • [32] Biomechanical effects of fascial hydrorelease: a cadaveric study
    Shiwaku, Kousuke
    Otsubo, Hidenori
    Suzuki, Daisuke
    Pirri, Calmero
    Kodesyo, Taiki
    Kamiya, Tomoaki
    Taniguchi, Keigo
    Ohnishi, Hirofumi
    Teramoto, Atsushi
    Stecco, Carla
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [33] Torsional stability of primary total knee replacement tibial prostheses - A biomechanical study in cadaveric bone
    Sala, M
    Taylor, M
    Tanner, KE
    JOURNAL OF ARTHROPLASTY, 1999, 14 (05): : 610 - 615
  • [34] Biomechanical analysis of cement augmentation techniques on pedicle screw fixation in osteopenic bone: A cadaveric study
    Benson C.D.
    Lansford T.
    Cotton J.
    Burton D.
    Jackson R.S.
    McIff T.
    Spine Deformity, 2014, 2 (1) : 28 - 33
  • [35] Validity of synthetic bone as a substitute for osteoporotic cadaveric femoral heads in mechanical testing A BIOMECHANICAL STUDY
    O'Neill, F.
    Condon, F.
    McGloughlin, T.
    Lenehan, B.
    Coffey, C.
    Walsh, M.
    BONE & JOINT RESEARCH, 2012, 1 (04): : 50 - 55
  • [36] Tendon With Z-Lengthening Technique and Construct Assessment: A Biomechanical Study for Use in Tendon Reconstructions
    Weller, William J.
    Goldstein, Zach
    Li, Fang
    Aljawad, Ahmed
    Greenberg, Jeffery A.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2020, 45 (07): : 661.e1 - 661.e10
  • [37] Biomechanical properties of a novel AC and CC stabilization technique using a novel cadaveric system with integration of the deltoideotrapezoideal fascia
    Bless, Nicolas
    Janis, Sailer
    Dalcanale, Federico
    Michael, De Wild
    Gueorguiev, Boyko
    Zderic, Ivan
    Knecht, Manuel
    Muller, Andreas
    SWISS MEDICAL WEEKLY, 2022, 152 : 10S - 10S
  • [38] Cadaveric Study of Colon-Lengthening Maneuvers After Sigmoidectomy
    Gupta, Abhinav
    Wlodarczyk, Jordan
    Yoon, Donghum
    Mirza, Kasim
    Wickham, Carey
    Taitano, Genia
    Cologne, Kyle
    Shin, Joongho
    DISEASES OF THE COLON & RECTUM, 2024, 67 (08) : 1030 - 1039
  • [39] CADAVERIC STUDY OF COLON LENGTHENING MANEUVERS FOLLOWING SIGMOIDECTOMY.
    Yoon, D.
    Mirza, K. L.
    Wickham, C.
    Cologne, K.
    Shin, J.
    DISEASES OF THE COLON & RECTUM, 2020, 63 (06) : E427 - E427
  • [40] Biomechanical assessment of freeze-dried allograft cortical bone plate graft in canine bone defect model
    Heo, S. Y.
    Lee, H. B.
    Lee, K. C.
    Kim, M. S.
    Na, C. S.
    Kim, N. S.
    VETERINARNI MEDICINA, 2009, 54 (04) : 183 - 190