Biomechanical assessment of a novel bone lengthening plate system - A cadaveric study

被引:0
|
作者
Jung, Tae Gon [1 ]
Suh, Seung Woo [2 ]
Lee, Sung Jae [3 ]
Kim, Bongju [4 ]
Han, Dong-Wook [1 ]
Yang, Jae Hyuk [2 ]
机构
[1] Pusan Natl Univ, Coll Nanosci & Nanotechnol, Dept Nanomed Engn, Pusan 609735, South Korea
[2] Korea Univ, Guro Hosp, Dept Orthoped, Scoliosis Res Inst, Seoul 152703, South Korea
[3] Inje Univ, Dept Biomed Engn, Gimhae Si 621749, Gyungnam, South Korea
[4] Kyoto Univ, Grad Sch Med, Ctr Innovat Immunoregulat Technol & Therapeut, Sakyo Ku, Kyoto 6068501, Japan
关键词
Femur; Biomechanical stability; Bone lengthening plate; Bone mineral density; LOCKING COMPRESSION PLATE; EXTERNAL FIXATORS; MECHANICAL PERFORMANCE; ILIZAROV TECHNIQUE; FIXATION; HYBRID; OSTEOSYNTHESIS; CORROSION; FRACTURE; COMPLICATIONS;
D O I
10.1016/j.clinbiomech.2012.11.011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Although many types of external fixators have been developed for distraction osteogenesis, all have some drawbacks. We recently developed a novel bone lengthening plate to overcome these problems. The purpose of this study is to conduct biomechanical analyses using cadavers to assess the stability of the bone lengthening plate in relation to distraction length and femoral bone mineral density. Methods: We used human cadaveric femurs (n=18) to assess the effects of distraction length and bone mineral density on the biomechanical stability of the bone lengthening plate. After establishing control (n = 6, 0 mm lengthening) and experimental groups (n = 12, 30 mm lengthening), we measured biomechanical stability (structural stiffness, ultimate load, and displacement) under a compressive load. The experimental group was subdivided into a group with normal bone mineral density (n=6) and a group with osteoporosis (n=6), and the biomechanical stability of these groups was compared. Finding: Structural stiffness differed significantly between the control (417.6 N/mm) and combined experimental groups (185.6 N/mm, p = 0.002). Ultimate load also differed significantly between the control (1327.8 N) and combined experimental (331.4 N, p = 0.002) groups. Bone mineral density was unrelated to structural stiffness (p=0.204), ultimate load (0.876), or displacement (0.344). In all cases, failure of the bone lengthening plate occurred at the longitudinal connectors, such as the connecting columns between the upper and lower plates, and the lengthening shaft of the bone lengthening plate. Interpretation: The biomechanical stability of the bone lengthening plate was affected by the lengthening length but not by bone mineral density. In addition, biomechanical stability during lengthening was most strongly influenced by the longitudinal connectors. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:232 / 238
页数:7
相关论文
共 50 条
  • [21] A novel instrument for ligament balancing: a biomechanical study in human cadaveric knees
    Engseth, Lars H. W.
    Gronsund, Jorgen
    Aunan, Eirik
    Brattgjerd, Jan Egil
    Schulz, Anselm
    Moatshe, Gilbert
    Roehrl, Stephan M.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2023, 10 (01)
  • [22] Assessment of L5-S1 anterior lumbar interbody fusion stability in the setting of lengthening posterior instrumentation constructs: a cadaveric biomechanical study
    McGrath, Kyle A.
    Schmidt, Eric S.
    Loss, Jeremy G.
    Gillespie, Callan M.
    Colbrunn, Robb W.
    Butler, Robert S.
    Steinmetz, Michael P.
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 36 (06) : 900 - 908
  • [23] Biomechanical study of a novel self-locking plate system for anterior cervical fixation
    Lifeng Lao
    Qianyi Li
    Guibin Zhong
    Chao Song
    Yuanchao Li
    Mingze Xu
    Zude Liu
    Journal of Orthopaedic Surgery and Research, 9
  • [24] Biomechanical study of a novel self-locking plate system for anterior cervical fixation
    Lao, Lifeng
    Li, Qianyi
    Zhong, Guibin
    Song, Chao
    Li, Yuanchao
    Xu, Mingze
    Liu, Zude
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2014, 9 : 120
  • [25] Biomechanical properties of a novel cervical spine implant with elastic deformation: a cadaveric study
    Abudouaini, Haimiti
    Wu, Tingkui
    Meng, Yang
    Ding, Chen
    Liu, Hao
    Beiyu, Wang
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [26] An anatomical and biomechanical assessment of the interosseous membrane of the cadaveric forearm
    Bin Abd Razak, Hamid Rahmatullah
    Yew, Khye-Soon Andy
    Moideen, Irwan Shah Bin Mohd
    Tay, Xian-Khing Kenny
    Howe, Tet-Sen
    Koh, Suang-Bee Joyce
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (04) : 369 - 374
  • [27] Biomechanical Evaluation of a Novel Expandable Vertebral Augmentation System Using Human Cadaveric Vertebrae
    Hsieh, Ming-Kai
    Chen, Wen-Jer
    Lee, Mel S.
    Lin, Sheng-Yu
    Liu, Mu-Yi
    Lee, De-Mei
    Tai, Ching-Lung
    APPLIED SCIENCES-BASEL, 2022, 12 (19):
  • [28] The Fixion proximal femur nailing system: biomechanical properties of the nail and a cadaveric study
    Steinberg, EL
    Blumberg, N
    Dekel, S
    JOURNAL OF BIOMECHANICS, 2005, 38 (01) : 63 - 68
  • [29] The biomechanical properties of the hook plate and pull-out suture in mallet finger fractures: a cadaveric study
    Suwannaphisit, Sitthiphong
    Saengsirinavin, Pamok
    Panichnantho, Nipat
    Kwanyuang, Atichart
    Gonggoon, Akkharaphon
    Jaroenporn, Woraphon
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2024, 49 (04) : 430 - 435
  • [30] Staple-Plate Plus Screw vs Screw Alone in Talonavicular Arthrodesis: A Cadaveric Biomechanical Study
    O'Neil, Joseph T.
    Abbasi, Pooyan
    Parks, Brent G.
    Miller, Stuart D.
    FOOT & ANKLE INTERNATIONAL, 2020, 41 (11) : 1427 - 1431