Comparison of the effects of cement removal from zirconia and titanium abutments: An in vitro study

被引:8
|
作者
Dahiya, Ankur [1 ]
Baba, Nadim Z. [2 ]
Kattadiyil, Mathew T. [3 ]
Goodacre, Charles J. [3 ]
Mann, Akshita [4 ]
机构
[1] Univ Texas Houston, Sch Dent, Dept Restorat Dent & Prosthodont, Suite 5337,7500 Cambridge St, Houston, TX 77054 USA
[2] Loma Linda Sch Dent, Hugh Love Ctr Res & Educ Technol, Loma Linda, CA USA
[3] Loma Linda Univ, Sch Dent, Adv Specialty Educ Program Prosthodont, Loma Linda, CA 92350 USA
[4] Univ Texas Houston, Sch Dent, Dept Endodont, Houston, TX 77054 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2019年 / 121卷 / 03期
关键词
PLASTIC INSTRUMENTS; IMPLANT ABUTMENTS; EXCESS CEMENT; BOND STRENGTH; RESTORATIONS; SURFACE; CERAMICS; METAL; COLOR;
D O I
10.1016/j.prosdent.2018.07.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Excess cement around dental implants is a significant cause of peri-implant inflammation. Research has focused on approaches to cement removal, the type of cement used, and the different instruments used for cement removal with titanium abutments. However, data comparing zirconia with titanium abutments are lacking. Purpose. The purpose of this in vitro study was to compare the effectiveness of excess cement removal from zirconia and titanium custom abutments using an explorer and to compare the effects of cement removal on the abutment surfaces. Material and methods. Implant analogs were placed in a cast in the position of the 2 maxillary central incisors. After creating similar emergence profiles for both the implant abutments, 18 zirconia and titanium custom abutments were fabricated with 1-mm subgingival finish lines on the facial and interproximal areas and an equigingival finish line on the palatal side. The crowns were cemented with zinc oxide-eugenol cement, and a steel explorer was used to remove the excess cement. All abutments were analyzed under a scanning electron microscope for cement remnants and scratches. Results. The mean surface area of cement remnants on the zirconia abutments was 778 +/- 113 mu m(2 )and for titanium abutments, it was 1123 +/- 252 mu m(2), which in terms of the mean percentage area was 3.27% of the total surface area of zirconia and 4.71% of titanium abutments. Only a few abutments from each group showed scratches, and no deep scratches or gouges were observed. Conclusions. Zirconia and titanium abutments had statistically similar cement remnants. Scratches were observed on only a few specimens.
引用
收藏
页码:504 / 509
页数:6
相关论文
共 50 条
  • [1] FRACTURE RESISTANCE OF TITANIUM AND ZIRCONIA ABUTMENTS: AN IN VITRO STUDY
    Foong, Jamie K. W.
    Judge, Roy B.
    Palamara, Joseph E.
    Swain, Michael V.
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 109 (05): : 304 - 312
  • [2] A Comparison of Zirconia and Titanium Abutments for Microleakage
    Abdelhamed, Mohamed I.
    Galley, Jeffrey D.
    Bailey, Michael T.
    Johnston, William M.
    Holloway, Julie
    McGlumphy, Edwin
    Leblebicioglu, Binnaz
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E643 - E651
  • [3] Cement removal from restorations luted to titanium abutments with simulated subgingival margins
    Agar, JR
    Cameron, SM
    Hughbanks, JC
    Parker, MH
    JOURNAL OF PROSTHETIC DENTISTRY, 1997, 78 (01): : 43 - 47
  • [4] Titanium and Zirconia External Connection Abutments Produced Following a Digital Protocol: An In Vitro Study
    Vigolo, Paolo
    Fonzi, Fulvio
    Zaccaria, Massimiliano
    Mutinelli, Sabrina
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (04) : 358 - 360
  • [5] An in vitro evaluation of titanium, zirconia, and alumina Procera abutments with hexagonal connection
    Vigolo, Paolo
    Fonzi, Fulvio
    Majzoub, Zeina
    Cordioli, Giampiero
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2006, 21 (04) : 575 - 580
  • [6] Screw stability of CAD-CAM titanium and zirconia abutments on different implants: An in vitro study
    Yilmaz, Burak
    Cakmak, Gulce
    Batak, Burcu
    Johnston, William M.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (03) : 373 - 379
  • [7] Evaluation of the effect of anodization-colored titanium abutments and zirconia substructure thickness on zirconia substructure color: An In vitro study
    Bas, B.
    Cakan, U.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2022, 25 (12) : 2024 - 2029
  • [8] Comparison of the residual cement on custom computer-aided design and computer-aided manufacturing titanium and zirconia abutments: A preliminary cohort study
    Hsu, Kuang-Wei
    Liang, Chao-Hua
    Peng, Ying-Chin
    Hsiao, Chih-Chien
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 618 - 624
  • [9] Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro
    Daehne, Felix
    Meissner, Heike
    Boening, Klaus
    Arnold, Christin
    Gutwald, Ralf
    Prause, Elisabeth
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [10] In Vitro Fatigue and Fracture Strength Testing of One-Piece Zirconia Implant Abutments and Zirconia Implant Abutments Connected to Titanium Cores
    Stimmelmayr, Michael
    Sagerer, Stefanie
    Erdelt, Kurt
    Beuer, Florian
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 488 - 493