Simple method for ion current measurement at RF biased electrode

被引:1
|
作者
Kawata, H [1 ]
Yasuda, M [1 ]
Hirai, Y [1 ]
机构
[1] Osaka Prefecture Univ, Grad Sch Engn, Sakai, Osaka 5998531, Japan
关键词
inductively coupled plasma; RF bias; plasma impedance; conduction current; ion current;
D O I
10.1016/j.tsf.2005.08.116
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Samples are usually placed on an RF bias electrode for an inductively coupled plasma device. The RF current and voltage waveforms at the bias electrode were measured. The current through the stray capacitance was cancelled by an LC cancel circuit. Only the sheath impedance at the bias electrode was considered as the equivalent circuit, The RF voltage greatly depended on the RF power, but the RF current slightly depended on the RF power. The conduction current could be related to the plasma density. The incident ion current to the bias electrode was given by the half value of the amplitude of the conduction current. The obtained incident ion current agreed with those obtained from different methods. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:683 / 687
页数:5
相关论文
共 50 条
  • [41] A New Measurement Method for High Voltages Applied to an Ion Trap Generated by an RF Resonator
    Park, Yunjae
    Jung, Changhyun
    Seong, Myeongseok
    Lee, Minjae
    Cho, Dongil Dan
    Kim, Taehyun
    SENSORS, 2021, 21 (04) : 1 - 14
  • [42] HYDROXYL ION MEASUREMENT WITH GLASS ELECTRODE
    ECKFELDT, EL
    OTT, WT
    ISA TRANSACTIONS, 1970, 9 (01) : 45 - &
  • [43] A SIMPLE, SENSITIVE METHOD FOR DETERMINATION OF BONE FLUORIDE USING AN ION-SELECTIVE ELECTRODE
    POCHOMIS, AM
    GRIFFITH, FD
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1970, 31 (02): : 6 - &
  • [44] A SIMPLE OXYGEN ELECTRODE CHAMBER AND METHOD FOR MEASUREMENT OF PHOTOSYNTHETIC O2 EVOLUTION
    SHUGARMA.PM
    APPLEMAN, D
    ANALYTICAL BIOCHEMISTRY, 1967, 18 (02) : 193 - &
  • [45] Spatiotemporal characteristics of the collisionless rf sheath and the ion energy distributions arriving at rf-biased electrodes
    Dai, ZL
    Wang, YN
    Ma, TC
    PHYSICAL REVIEW E, 2002, 65 (03):
  • [46] Measurement Technology of RF Interference Current in High Current System
    Zhao, Zhihua
    Li, Jianxuan
    Zhang, Xiangming
    Zhang, Lei
    MATERIALS SCIENCE, ENERGY TECHNOLOGY AND POWER ENGINEERING II (MEP2018), 2018, 1971
  • [47] Ion temperature measurement in the RF heated plasma
    Ko, Won Ha
    Na, Hoon Kyun
    Seo, Seong-Heon
    Kwon, Myeun
    FUSION SCIENCE AND TECHNOLOGY, 2007, 51 (2T) : 295 - 297
  • [48] PLASMA DENSITY MEASUREMENT OF RF ION SOURCE
    Voznyy, V. I.
    Miroshnichenko, V. I.
    Mordyk, S. M.
    Nagornyy, A. G.
    Nagornyy, D. A.
    Storizhko, V. E.
    Shulha, D. P.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2005, (01): : 209 - +
  • [49] SIMPLE ELECTRODE DESIGN FOR ION MOBILITY SPECTROMETER
    CARRICO, JP
    SICKENBERGER, DW
    SPANGLER, GE
    VORA, KN
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1983, 16 (11): : 1058 - 1062
  • [50] "Virtual IED sensor" at an rf-biased electrode in low-pressure plasma
    Bogdanova, M. A.
    Lopaev, D. V.
    Zyryanov, S. M.
    Rakhimov, A. T.
    PHYSICS OF PLASMAS, 2016, 23 (07)