Simple method for ion current measurement at RF biased electrode

被引:1
|
作者
Kawata, H [1 ]
Yasuda, M [1 ]
Hirai, Y [1 ]
机构
[1] Osaka Prefecture Univ, Grad Sch Engn, Sakai, Osaka 5998531, Japan
关键词
inductively coupled plasma; RF bias; plasma impedance; conduction current; ion current;
D O I
10.1016/j.tsf.2005.08.116
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Samples are usually placed on an RF bias electrode for an inductively coupled plasma device. The RF current and voltage waveforms at the bias electrode were measured. The current through the stray capacitance was cancelled by an LC cancel circuit. Only the sheath impedance at the bias electrode was considered as the equivalent circuit, The RF voltage greatly depended on the RF power, but the RF current slightly depended on the RF power. The conduction current could be related to the plasma density. The incident ion current to the bias electrode was given by the half value of the amplitude of the conduction current. The obtained incident ion current agreed with those obtained from different methods. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:683 / 687
页数:5
相关论文
共 50 条
  • [21] A Simple Method for Ion Channel Recordings Using Fine Gold Electrode
    Okuno, Daichi
    Hirano, Minako
    Yokota, Hiroaki
    Onishi, Yukiko
    Ichinose, Junya
    Ide, Toru
    ANALYTICAL SCIENCES, 2016, 32 (12) : 1353 - 1357
  • [22] SIMPLE METHOD FOR ESTIMATION OF PLASMA AMMONIA USING AN ION SPECIFIC ELECTRODE
    PARK, NJ
    FENTON, JCB
    JOURNAL OF CLINICAL PATHOLOGY, 1973, 26 (10) : 802 - 804
  • [23] Ion flux and energy virtual sensor for measuring ion flux and energy distribution at a RF biased electrode in ICP reactor (RIE-mode)
    Bogdanova, M. A.
    Lopaev, D. V.
    Zyryanov, S. M.
    6TH INTERNATIONAL WORKSHOP & SUMMER SCHOOL ON PLASMA PHYSICS 2014 (IWSSPP'14), 2016, 768
  • [24] MEASUREMENT OF ION ENERGY-DISTRIBUTIONS AT THE POWERED RF ELECTRODE IN A VARIABLE MAGNETIC-FIELD
    KUYPERS, AD
    HOPMAN, HJ
    JOURNAL OF APPLIED PHYSICS, 1990, 67 (03) : 1229 - 1240
  • [25] Ion energy distributions at rf-biased wafer surfaces
    Woodworth, JR
    Abraham, IC
    Riley, ME
    Miller, PA
    Hamilton, TW
    Aragon, BP
    Shul, RJ
    Willison, CG
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 2002, 20 (03): : 873 - 886
  • [26] CURRENT-PHASE RELATIONS AND NOISE IN RF BIASED SQUIDS
    JACKEL, LD
    CLARK, TD
    BUHRMAN, RA
    IEEE TRANSACTIONS ON MAGNETICS, 1975, MA11 (02) : 732 - 735
  • [27] Measurement of electrode parameters of RF waveguide lasers
    Tian, Zhaoshuo
    Wang, Yusan
    Liu, Fengmei
    Zhao, Jingshan
    Wang, Qi
    Zhongguo Jiguang/Chinese Journal of Lasers, 1999, 26 (02): : 135 - 140
  • [28] MEASUREMENT OF BLOOD CYANIDE WITH A MICRODIFFUSION METHOD AND AN ION-SPECIFIC ELECTRODE
    YAGI, K
    IKEDA, S
    SCHWEISS, JF
    HOMAN, SM
    ANESTHESIOLOGY, 1990, 73 (05) : 1028 - 1031
  • [29] The method of ion current measurement on capacitive-coupled plasma
    Iseki, Y
    Hayashi, K
    Noda, E
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (02): : 1391 - 1394
  • [30] A Simple NFC RF Performance Measurement Method Based on ISO/IEC 14443 Standard
    Chen, I-Fong
    Peng, Chia-Mei
    Yan, Zhi-Da
    IEEE JOURNAL OF RADIO FREQUENCY IDENTIFICATION, 2020, 4 (04): : 438 - 443