A Pulsatile Optical Tissue Phantom for the Investigation of Light-Tissue Interaction in Reflectance Photoplethysmography

被引:0
|
作者
Nomoni, Michelle [1 ]
May, James M. [1 ]
Kyriacou, Panayiotis A. [1 ]
机构
[1] City Univ London, Sch Math Comp Sci & Engn, London EC1V 0HB, England
关键词
SIGNAL; SKIN;
D O I
10.1109/embc.2019.8857036
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to investigate the effect of emitter-detector separation distance and arterial depth in reflectance photoplethysmography (PPG), utilizing a homogenous pulsatile phantom that exhibits the broad optical absorbance and scattering properties of human tissue. The developed phantom comprised of embedded silicone arteries (outer diameter = 4 mm) that were arranged parallel to one another at nine increasing depths (3.2 mm to 24.4 mm). A pulsatile pump (Harvard Apparatus, MA, USA) circulated a blood imitating fluid through the vessels at the desired heart rate (60 bpm) and stroke volume (5 Lmin(-1)). The PPG sensor's emitter and detector were isolated on a translation bridge to provide a computer-controlled separation distance between them. Recordings were taken at each vessel depth for emitter-detector separation distances from 2 mm to 8 mm in 0.1 mm steps. The optimum separation distance between the emitter and detector for vessels between depths of 3.2 mm and 10.5 mm was between 3.7 and 4.3 mm, suggesting that the maximum penetration of IR (930 nm) light in a homogenous pulsatile phantom is no greater than 10.5 mm.
引用
收藏
页码:3204 / 3207
页数:4
相关论文
共 50 条
  • [31] Relevance of the structure of time-resolved spectral output to light-tissue interaction using intense pulsed light (IPL)
    Ash, Caerwyn
    Town, Godfrey
    Bjerring, Peter
    LASERS IN SURGERY AND MEDICINE, 2008, 40 (02) : 83 - 92
  • [32] Monte Carlo modeling of light-tissue interactions in narrow band imaging
    Le, Du V. N.
    Wang, Quanzeng
    Ramella-Roman, Jessica C.
    Pfefer, T. Joshua
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (01)
  • [33] Measurements of optical parameters of tissue phantom
    Hu, YZ
    Liu, Y
    Zhang, XJ
    Han, YH
    PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, 2003, 5254 : 402 - 407
  • [34] Light-tissue interactions I: Photothermolysis vs photomodulation laboratory findings
    McDaniel, DH
    Weiss, R
    Geronemus, R
    Ginn, L
    Newman, J
    LASERS IN SURGERY AND MEDICINE, 2002, : 25 - 25
  • [35] Retrieval of chromophore concentration in a tissue phantom by diffuse reflectance spectroscopy
    A. Sircan-Kucuksayan
    M. Canpolat
    Optics and Spectroscopy, 2014, 117 : 663 - 669
  • [36] Retrieval of chromophore concentration in a tissue phantom by diffuse reflectance spectroscopy
    Sircan-Kucuksayan, A.
    Canpolat, M.
    OPTICS AND SPECTROSCOPY, 2014, 117 (04) : 663 - 669
  • [37] Design and evaluation of a parallel and optimized light-tissue interaction-based method for fast skin lesion assessment
    Li, Chao
    Brost, Vincent
    Benezeth, Yannick
    Marzani, Franck
    Yang, Fan
    JOURNAL OF REAL-TIME IMAGE PROCESSING, 2018, 15 (02) : 407 - 420
  • [38] Characterization and selection of wavelengths in the light-tissue interaction model oriented to the analysis of multi-spectral images of skin
    Bermudez Mejia, Camilo Alejandro
    Galeano Zea, July Andrea
    OBRAS COLECTIVAS EN CIENCIAS DE LA COMPUTACION, 2018, : 385 - 397
  • [39] Photoacoustic location of optical absorbers in phantom tissue
    Hoelen, CGA
    Hamhuis, G
    Pagoulatos, N
    vandenHam, I
    deMul, FFM
    Greve, J
    OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING II, PROCEEDINGS OF, 1996, 2927 : 142 - 153
  • [40] Investigation of laser-tissue-interaction for optical cochlea stimulation
    Kallweit, N.
    Maier, H.
    Schultz, M.
    Tinne, N.
    Krueger, A.
    Kral, A.
    Ripken, T.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S735 - S735