A Pulsatile Optical Tissue Phantom for the Investigation of Light-Tissue Interaction in Reflectance Photoplethysmography

被引:0
|
作者
Nomoni, Michelle [1 ]
May, James M. [1 ]
Kyriacou, Panayiotis A. [1 ]
机构
[1] City Univ London, Sch Math Comp Sci & Engn, London EC1V 0HB, England
关键词
SIGNAL; SKIN;
D O I
10.1109/embc.2019.8857036
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to investigate the effect of emitter-detector separation distance and arterial depth in reflectance photoplethysmography (PPG), utilizing a homogenous pulsatile phantom that exhibits the broad optical absorbance and scattering properties of human tissue. The developed phantom comprised of embedded silicone arteries (outer diameter = 4 mm) that were arranged parallel to one another at nine increasing depths (3.2 mm to 24.4 mm). A pulsatile pump (Harvard Apparatus, MA, USA) circulated a blood imitating fluid through the vessels at the desired heart rate (60 bpm) and stroke volume (5 Lmin(-1)). The PPG sensor's emitter and detector were isolated on a translation bridge to provide a computer-controlled separation distance between them. Recordings were taken at each vessel depth for emitter-detector separation distances from 2 mm to 8 mm in 0.1 mm steps. The optimum separation distance between the emitter and detector for vessels between depths of 3.2 mm and 10.5 mm was between 3.7 and 4.3 mm, suggesting that the maximum penetration of IR (930 nm) light in a homogenous pulsatile phantom is no greater than 10.5 mm.
引用
收藏
页码:3204 / 3207
页数:4
相关论文
共 50 条
  • [21] 3-D interactive visualization of light-tissue interaction using Java']Java
    Splinter, R
    Ramaiah, R
    Deshmukh, H
    Raja, MYA
    APPLICATIONS OF PHOTONIC TECHNOLOGY 4: CLOSING THE GAP BETWEEN THEORY, DEVELOPMENT, AND APPLICATION, 2000, 4087 : 1067 - 1078
  • [22] Light-Tissue Interaction Model for the Analysis of Skin Ulcer Multi-spectral Images
    Galeano, July
    Jose Tapia-Escalante, Pedro
    Milena Perez-Buitrago, Sandra
    Hernandez-Hoyos, Yesid
    Fernanda Arias-Munoz, Luisa
    Zarzycki, Artur
    Garzon-Reyes, Johnson
    Marzani, Franck
    VIPIMAGE 2017, 2018, 27 : 754 - 761
  • [23] Effect of wavelength and beam width on penetration in light-tissue interaction using computational methods
    Caerwyn Ash
    Michael Dubec
    Kelvin Donne
    Tim Bashford
    Lasers in Medical Science, 2017, 32 : 1909 - 1918
  • [24] Teaching light-tissue interactions: using technology for education
    Nogueira, Marcelo Saito
    Gunther, Jacqueline
    Komolibus, Katarzyna
    Andersson-Engels, Stefan
    OPTICAL INTERACTIONS WITH TISSUE AND CELLS XXX, 2019, 10876
  • [25] Advances in the simulation of light-tissue interactions in biomedical engineering
    Krasnikov, Ilya
    Seteikin, Alexey
    Roth, Bernhard
    BIOMEDICAL ENGINEERING LETTERS, 2019, 9 (03) : 327 - 337
  • [26] Estimating soft tissue thickness from light-tissue interactions-a simulation study
    Wissel, Tobias
    Bruder, Ralf
    Schweikard, Achim
    Ernst, Floris
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (07): : 1176 - 1187
  • [27] Diffuse reflectance spectrophotometry with visible light:: comparison of four different methods in a tissue phantom
    Gade, J
    Palmqvist, D
    Plomgård, P
    Greisen, G
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (01): : 121 - 136
  • [28] A new optical coefficient of biological tissue that determines the diffuse reflectance light distribution on the tissue surface
    Zhang, Lianshun
    JOURNAL OF MODERN OPTICS, 2008, 55 (11) : 1731 - 1738
  • [29] Brain Light-Tissue Interaction Modelling: Towards a non-invasive sensor for Traumatic Brain Injury
    Roldan, M.
    Chatterjee, S.
    Kyriacou, P. A.
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 1292 - 1296
  • [30] Computer-aided generation of reference data for 3-D evaluation of light-tissue interaction
    Cysewska-Sobusiak, A
    Malitka, E
    LIGHT AND OPTICS IN BIOMEDICINE, 2000, 4515 : 212 - 220