A Pulsatile Optical Tissue Phantom for the Investigation of Light-Tissue Interaction in Reflectance Photoplethysmography

被引:0
|
作者
Nomoni, Michelle [1 ]
May, James M. [1 ]
Kyriacou, Panayiotis A. [1 ]
机构
[1] City Univ London, Sch Math Comp Sci & Engn, London EC1V 0HB, England
关键词
SIGNAL; SKIN;
D O I
10.1109/embc.2019.8857036
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to investigate the effect of emitter-detector separation distance and arterial depth in reflectance photoplethysmography (PPG), utilizing a homogenous pulsatile phantom that exhibits the broad optical absorbance and scattering properties of human tissue. The developed phantom comprised of embedded silicone arteries (outer diameter = 4 mm) that were arranged parallel to one another at nine increasing depths (3.2 mm to 24.4 mm). A pulsatile pump (Harvard Apparatus, MA, USA) circulated a blood imitating fluid through the vessels at the desired heart rate (60 bpm) and stroke volume (5 Lmin(-1)). The PPG sensor's emitter and detector were isolated on a translation bridge to provide a computer-controlled separation distance between them. Recordings were taken at each vessel depth for emitter-detector separation distances from 2 mm to 8 mm in 0.1 mm steps. The optimum separation distance between the emitter and detector for vessels between depths of 3.2 mm and 10.5 mm was between 3.7 and 4.3 mm, suggesting that the maximum penetration of IR (930 nm) light in a homogenous pulsatile phantom is no greater than 10.5 mm.
引用
收藏
页码:3204 / 3207
页数:4
相关论文
共 50 条
  • [1] Novel Polydimethylsiloxane (PDMS) Pulsatile Vascular Tissue Phantoms for the In-Vitro Investigation of Light Tissue Interaction in Photoplethysmography
    Nomoni, Michelle
    May, James M.
    Kyriacou, Panayiotis A.
    SENSORS, 2020, 20 (15) : 1 - 13
  • [2] Monte Carlo simulation of the effect of melanin concentration on light-tissue interactions in transmittance and reflectance finger photoplethysmography
    Al-Halawani, Raghda
    Qassem, Meha
    Kyriacou, Panicos A.
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [3] The Light-Tissue Interaction of Pulse Oximetry
    Mannheimer, Paul D.
    ANESTHESIA AND ANALGESIA, 2007, 105 : S10 - S17
  • [4] Transcranial Light-Tissue Interaction Analysis
    Aulakh, Kavleen
    Zakaib, Scott
    Willmore, William G.
    Ye, Winnie N.
    OPTICAL INTERACTIONS WITH TISSUE AND CELLS XXVII, 2016, 9706
  • [5] The Plasma Membrane is Involved in the Visible Light-Tissue Interaction
    Lavi, Ronit
    Ankri, Rinat
    Sinyakov, Michael
    Eichler, Maor
    Friedmann, Harry
    Shainberg, Asher
    Breitbart, Haim
    Lubart, Rachel
    PHOTOMEDICINE AND LASER SURGERY, 2012, 30 (01) : 14 - 19
  • [6] Effects of Contact Pressure in Reflectance Photoplethysmography in an In Vitro Tissue-Vessel Phantom
    May, James M.
    Mejia-Mejia, Elisa
    Nomoni, Michelle
    Budidha, Karthik
    Choi, Changmok
    Kyriacou, Panicos A.
    SENSORS, 2021, 21 (24)
  • [7] Study of temperature distribution in light-tissue interaction using the FEM
    Citkaya, Ahmet Yasin
    Seker, Saban Selim
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2016, 24 (03) : 807 - 819
  • [8] Experimental verification and validation of a computer model for light-tissue interaction
    Karsten, Aletta Elizabeth
    Singh, Ann
    Braun, Max W.
    LASERS IN MEDICAL SCIENCE, 2012, 27 (01) : 79 - 86
  • [9] Optical software - Phantoms enhance modeling of light-tissue interactions
    Kincade, Kathy
    LASER FOCUS WORLD, 2006, 42 (10): : 42 - +
  • [10] Optical-thermal light-tissue interactions during photoacoustic imaging
    Gould, Taylor
    Wang, Quanzeng
    Pfefer, T. Joshua
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES VII, 2014, 8936