Optimization of phagocyte chemiluminescence measurements using microplates and vials

被引:0
|
作者
Hengster, P [1 ]
Kunc, M [1 ]
Linke, R [1 ]
Eberl, T [1 ]
Steurer, W [1 ]
Öfner, D [1 ]
Berthold, F [1 ]
Margreiter, R [1 ]
机构
[1] Univ Innsbruck Hosp, Dept Surg, A-6020 Innsbruck, Austria
关键词
luminol; chemiluminescence; phagocytes; microplates;
D O I
10.1002/(SICI)1522-7243(199903/04)14:2<91::AID-BIO518>3.0.CO;2-Y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to cope with large amounts of samples for chemiluminescence (CL), vials were replaced with microplates. Although various types of plates have been commercially available for quite some time and the free-plate mode is advocated by the producer of the counter, little is known about their impact on the outcome of CL measurements. We tested two different 24-well microplates and six different 96-well microplates in two different luminometers, and results were compared with those achieved with vials. Before these comparative tests, we attempted to optimize measurement conditions. CL sensitivity was highest with luminol concentrations of 0.8-3.3 mu mol/L, PMA concentrations of 0.06-80 mu mol/L, a pH value of 10 and a temperature of 20 degrees C. An indirect correlation was found between fluid volume and yield in counts: the lower the volume, the higher the counts. With regard to sensitivity and cross-talk, the 96-well Isoplate(TM) was superior to all other plates tested. While all white plates tested gave acceptable results, usage of the black 96-well plates resulted in an extremely low sensitivity. Plates designed for cell culturing gave even lower counts and a cross-talk of up to 31%. All attempts to reduce cross-talk and improve sensitivity, such as aluminium foil or grids, irrespective of the position of the photomultiplier, did not give results comparable to the original 96-well isoplate. Our results suggest that, with the exception of black 96-well microplates and cell culture plates, all other plates tested have a sufficient sensitivity when compared to vials and acceptable cross-talk, the 96-well Isoplate(TM) being the best. Both types of luminometers used gave reproducible results, Wallac having a somewhat higher sensitivity, Canberra Packard somewhat less cross-talk. Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:91 / 98
页数:8
相关论文
共 50 条
  • [21] Glucocorticoid and ACTH regulation of rat peritoneal phagocyte chemiluminescence and nitric oxide production in culture
    Haugen, SE
    Wiik, P
    ACTA PHYSIOLOGICA SCANDINAVICA, 1997, 161 (01): : 93 - 101
  • [22] Cell adhesion markedly increases lucigenin-enhanced chemiluminescence of the phagocyte NADPH oxidase
    Kuribayashi, Futoshi
    Tsuruta, Satoru
    Yamazaki, Tsuyoshi
    Nunoi, Hiroyuki
    Imajoh-Ohmi, Shinobu
    Kanegasaki, Shiro
    Nakamura, Michio
    GENES TO CELLS, 2008, 13 (12) : 1249 - 1256
  • [23] Vibration and buckling optimization of functionally graded porous microplates using BCMO-ANN algorithm
    Van-Thien Tran
    Trung-Kien Nguyen
    Nguyen-Xuan, H.
    Wahab, Magd Abdel
    THIN-WALLED STRUCTURES, 2023, 182
  • [24] CERENKOV COUNTING USING TEFLON VIALS
    CALF, GE
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1977, 28 (08): : 737 - 738
  • [25] DEXAMETHASONE AND METHYLPREDNISOLONE AFFECT RAT PERITONEAL PHAGOCYTE CHEMILUMINESCENCE AFTER ADMINISTRATION IN-VIVO
    ROSHOL, H
    SKREDE, KK
    AERO, CE
    WIIK, P
    EUROPEAN JOURNAL OF PHARMACOLOGY, 1995, 286 (01) : 9 - 17
  • [26] A novel ELISA using PVDF microplates
    Halim, ND
    Joseph, AW
    Lipska, BK
    JOURNAL OF NEUROSCIENCE METHODS, 2005, 143 (02) : 163 - 168
  • [27] Characterization of damping in vibrating microplates through measurements in the time domain
    De Pasquale, Giorgio
    Soma, Aurelio
    2012 SYMPOSIUM ON DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS (DTIP), 2012, : 76 - 81
  • [28] Optimization of acceleration measurements using PIV
    Jensen, A
    Pedersen, GK
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (11) : 2275 - 2283
  • [29] Effect of fuel type on equivalence ratio measurements using chemiluminescence in premixed flames
    Orain, Mikael
    Hardalupas, Yannis
    COMPTES RENDUS MECANIQUE, 2010, 338 (05): : 241 - 254
  • [30] OPTIMIZATION OF LIQUID SCINTILLATION-COUNTING CONDITIONS WITH 2 KINDS OF VIALS AND DETECTOR SHIELDS FOR LOW-ACTIVITY RADIOCARBON MEASUREMENTS
    RAURET, G
    MESTRES, JS
    GARCIA, JF
    RADIOCARBON, 1989, 31 (03) : 380 - 386