Effect of Burst Frequency and Duration of Kilohertz-Frequency Alternating Currents and of Low-Frequency Pulsed Currents on Strength of Contraction, Muscle Fatigue, and Perceived Discomfort

被引:48
|
作者
Laufer, Yocheved [1 ]
Elboim, Michal [1 ]
机构
[1] Univ Haifa, Phys Therapy Dept, Fac Social Welf & Hlth Studies, IL-31905 Haifa, Israel
来源
PHYSICAL THERAPY | 2008年 / 88卷 / 10期
关键词
D O I
10.2522/ptj.20080001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. Low-frequency Pulsed currents (LPCs) and kilohertz-frequency alternating Currents (KACs) are used clinically to augment muscle contractions. Treatment effectiveness may be enhanced by selecting Stimulation parameters that evoke the strongest contractions with minimal discomfort and fatigue. Objective. The objective of this study was to compare maximally induced strength (force-producing capacity) of contractions, muscle fatigue, and discomfort associated with an LPC and with 3 KACs differing in frequency and duration of burst modulation. Design. This was a repeated-measures trial, with randomized order Of Current presentation. Setting. The study was conducted in the physical therapy laboratory at the University of Haifa. Subjects. Twenty-six Volunteers without impairments, with a mean age of 27.4 years (SD=5.0, range=21-45), participated. Intervention. All Currents were applied in separate sessions to the wrist extensors of each subject. Currents consisted of an LPC with a 50-Hz pulse frequency and 3 KACs with a 2.5-kHz carrier frequency, including the "Russian Current" (RC) burst modulated at 50 Hz with 25 cycles per burst and 2 Currents burst modulated at 20 or 50 Hz with 10 cycles per burst. Measurement. The maximal electrically induced isometric force, the force integral of 21 electrically induced consecutive contractions, and the degree of discomfort were recorded. Results. Force of contraction was not affected by type of current. The LPC was least fatiguing, and the RC was Most fatiguing, with the 2 other KACs having an intermediate effect. Degree of discomfort was higher with the KAC modulated at 20 Hz. Conclusions. When comfort, strength, and fatigue are considered jointly, the LPC is advantageous. Electrically induced fatigue is affected by the number of cycles per second, rather than the number of bursts per second.
引用
收藏
页码:1167 / 1176
页数:10
相关论文
共 33 条
  • [1] Wrist extensor torque production and discomfort associated with low frequency and burst-modulated kilohertz-frequency currents
    Ward, Alex R.
    Oliver, Warwick G.
    Buccella, Danielle
    PHYSICAL THERAPY, 2006, 86 (10): : 1360 - 1367
  • [2] Low-Frequency Pulsed Current Versus Kilohertz-Frequency Alternating Current: A Scoping Literature Review
    Vaz, Marco Aurelio
    Frasson, Viviane Bortoluzzi
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2018, 99 (04): : 792 - 805
  • [3] Comparison of the hypoalgesic efficacy of low-frequency and burst-modulated kilohertz frequency currents
    Ward, Alex R.
    Oliver, Warwick G.
    PHYSICAL THERAPY, 2007, 87 (08): : 1056 - 1063
  • [4] Segmental and extrasegmental hypoalgesic effects of low-frequency pulsed current and modulated kilohertz-frequency currents in healthy subjects: randomized clinical trial
    Rampazo da Silva, Erika Patricia
    da Silva, Viviane Ribeiro
    Bernardes, Anabelly Sato
    Matuzawa, Fabio
    Liebano, Richard Eloin
    PHYSIOTHERAPY THEORY AND PRACTICE, 2021, 37 (08) : 916 - 925
  • [5] Effects of Kilohertz Frequency, Burst Duty Cycle, and Burst Duration on Evoked Torque, Perceived Discomfort and Muscle Fatigue A Systematic Review
    Modesto, Karenina Arrais Guida
    Bastos, Julia Aguillar Ivo
    Vaz, Marco Aurelio
    Durigan, Joao Luiz Quagliotti
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2023, 102 (02) : 175 - 183
  • [6] Muscle force production with low and medium frequency burst modulated biphasic pulsed currents
    Bellew, James W.
    Sanders, Kyle
    Schuman, Kristen
    Barton, Matt
    PHYSIOTHERAPY THEORY AND PRACTICE, 2014, 30 (02) : 105 - 109
  • [7] Lowering of sensory, motor, and pain-tolerance with burst duration using kilohertz-frequency current electric stimulation thresholds alternating
    Ward, Alex R.
    Lucas-Toumbourou, Stacey
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2007, 88 (08): : 1036 - 1041
  • [8] In vivo peripheral nerve activation using sinusoidal low-frequency alternating currents
    Alhawwash, Awadh
    Muzquiz, M. Ivette
    Richardson, Lindsay
    Vetter, Christian
    Smolik, Macallister
    Goodwill, Adam
    Yoshida, Ken
    ARTIFICIAL ORGANS, 2022, 46 (10) : 2055 - 2065
  • [9] Influence of kilohertz frequency, burst duty cycle and burst duration on evoked torque, discomfort and muscle efficiency: A randomized crossover trial
    Modesto, Karenina Arrais Guida
    Raposo, Priscila Karen Silva
    Almeida, Isabella da Silva
    Vaz, Marco Aurelio
    Durigan, Joao Luiz Quagliotti
    PHYSIOLOGICAL REPORTS, 2024, 12 (20):
  • [10] Effects of contraction duration on low-frequency fatigue in voluntary and electrically induced exercise of quadriceps muscle in humans
    Ratkevicius, A
    Skurvydas, A
    Povilonis, E
    Quistorff, B
    Lexell, J
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1998, 77 (05) : 462 - 468