Muscle force production with low and medium frequency burst modulated biphasic pulsed currents

被引:15
|
作者
Bellew, James W. [1 ]
Sanders, Kyle [1 ]
Schuman, Kristen [1 ]
Barton, Matt [1 ]
机构
[1] Univ Indianapolis, Krannert Sch Phys Therapy, Indianapolis, IN 46227 USA
关键词
Muscle; NMES; Russian; strengthening;
D O I
10.3109/09593985.2013.823582
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: Russian current, a medium frequency burst modulated alternating current (BMAC), is widely used for NMES, but has not been shown to elicit forces near voluntary maximum. In contrast, low frequency BMAC has been shown to produce greater force production than Russian and most recently, medium frequency burst modulated biphasic pulsed current (BMBPC) elicited greater force than Russian. Whether low frequency BMBPC yields greater force than medium frequency BMBPC is unknown. This study examined elicited forces using BMBPC with low and medium frequency carrier currents. Design: A cross-over design where percent maximal isometric knee extensor forces (%MVIF) elicited using BMBPC with low or medium kilohertz carrier frequencies were compared in 23 subjects. Perceived discomfort was also assessed. Data were compared using paired samples t-tests. Results: 98.4% of the MVIF was elicited with the low frequency BMBPC which was significantly greater (p < 0.001) than the 40.4% yielded by the medium frequency current. Cohen's d effect size of 2.146 indicated a "huge effect". Perceived discomfort of the low frequency current was 5.7/10 and was significantly greater (p < 0.001) than the medium frequency current (3.6/10). Conclusion: BMBPC with low frequency carrier current elicits forces approximating maximal volitional force. These findings offer new evidence with strong clinical implications when using NMES.
引用
收藏
页码:105 / 109
页数:5
相关论文
共 50 条
  • [1] Wrist extensor torque production and discomfort associated with low frequency and burst-modulated kilohertz-frequency currents
    Ward, Alex R.
    Oliver, Warwick G.
    Buccella, Danielle
    PHYSICAL THERAPY, 2006, 86 (10): : 1360 - 1367
  • [2] Effect of Burst Frequency and Duration of Kilohertz-Frequency Alternating Currents and of Low-Frequency Pulsed Currents on Strength of Contraction, Muscle Fatigue, and Perceived Discomfort
    Laufer, Yocheved
    Elboim, Michal
    PHYSICAL THERAPY, 2008, 88 (10): : 1167 - 1176
  • [3] Comparison of the hypoalgesic efficacy of low-frequency and burst-modulated kilohertz frequency currents
    Ward, Alex R.
    Oliver, Warwick G.
    PHYSICAL THERAPY, 2007, 87 (08): : 1056 - 1063
  • [4] Study protocol of hypoalgesic effects of low frequency and burst-modulated alternating currents on healthy individuals
    Rampazo da Silva, Erika Patricia
    da Silva, Viviane Ribeiro
    Bernardes, Anabelly Sato
    Matuzawa, Fabio Massao
    Liebano, Richard Eloin
    PAIN MANAGEMENT, 2018, 8 (02) : 71 - 77
  • [5] Muscle force development after low-frequency magnetic burst stimulation in dogs
    Emrich, Daniela
    Fischer, Andrea
    Fer, Caroline Altenhoe
    Weyh, Thomas
    Helling, Florian
    Goetz, Stefan
    Brielmeier, Markus
    Matiasek, Kaspar
    MUSCLE & NERVE, 2012, 46 (06) : 954 - 956
  • [6] Low frequency, pulsed eddy currents for deep penetration
    Ward, WW
    Moulder, JC
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 17A AND 17B, 1998, : 291 - 298
  • [7] Force Variability Is Related To Low-frequency Oscillations In Force And EMG Burst
    Christou, Evangelos A.
    Moon, Hwasil
    Kim, Changki
    Kwon, Minhyuk
    Chen, Yen Ting
    Onushko, Tanya
    Lodha, Neha
    Lodha, Neha
    Hass, Chris
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (05): : 674 - 674
  • [8] Segmental and extrasegmental hypoalgesic effects of low-frequency pulsed current and modulated kilohertz-frequency currents in healthy subjects: randomized clinical trial
    Rampazo da Silva, Erika Patricia
    da Silva, Viviane Ribeiro
    Bernardes, Anabelly Sato
    Matuzawa, Fabio
    Liebano, Richard Eloin
    PHYSIOTHERAPY THEORY AND PRACTICE, 2021, 37 (08) : 916 - 925
  • [9] Influence of Low-frequency Harmonic Currents on Radial Electromagnetic Force of PMSM
    Wang, Hongyu
    Wu, Jianhua
    2020 23RD INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2020, : 1574 - 1577
  • [10] Membrane potential and currents of isolated heart muscle cells exposed to pulsed radio frequency fields
    Linz, KW
    von Westphalen, C
    Streckert, J
    Hansen, V
    Meyer, R
    BIOELECTROMAGNETICS, 1999, 20 (08) : 497 - 511