Effect of Burst Frequency and Duration of Kilohertz-Frequency Alternating Currents and of Low-Frequency Pulsed Currents on Strength of Contraction, Muscle Fatigue, and Perceived Discomfort

被引:48
|
作者
Laufer, Yocheved [1 ]
Elboim, Michal [1 ]
机构
[1] Univ Haifa, Phys Therapy Dept, Fac Social Welf & Hlth Studies, IL-31905 Haifa, Israel
来源
PHYSICAL THERAPY | 2008年 / 88卷 / 10期
关键词
D O I
10.2522/ptj.20080001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. Low-frequency Pulsed currents (LPCs) and kilohertz-frequency alternating Currents (KACs) are used clinically to augment muscle contractions. Treatment effectiveness may be enhanced by selecting Stimulation parameters that evoke the strongest contractions with minimal discomfort and fatigue. Objective. The objective of this study was to compare maximally induced strength (force-producing capacity) of contractions, muscle fatigue, and discomfort associated with an LPC and with 3 KACs differing in frequency and duration of burst modulation. Design. This was a repeated-measures trial, with randomized order Of Current presentation. Setting. The study was conducted in the physical therapy laboratory at the University of Haifa. Subjects. Twenty-six Volunteers without impairments, with a mean age of 27.4 years (SD=5.0, range=21-45), participated. Intervention. All Currents were applied in separate sessions to the wrist extensors of each subject. Currents consisted of an LPC with a 50-Hz pulse frequency and 3 KACs with a 2.5-kHz carrier frequency, including the "Russian Current" (RC) burst modulated at 50 Hz with 25 cycles per burst and 2 Currents burst modulated at 20 or 50 Hz with 10 cycles per burst. Measurement. The maximal electrically induced isometric force, the force integral of 21 electrically induced consecutive contractions, and the degree of discomfort were recorded. Results. Force of contraction was not affected by type of current. The LPC was least fatiguing, and the RC was Most fatiguing, with the 2 other KACs having an intermediate effect. Degree of discomfort was higher with the KAC modulated at 20 Hz. Conclusions. When comfort, strength, and fatigue are considered jointly, the LPC is advantageous. Electrically induced fatigue is affected by the number of cycles per second, rather than the number of bursts per second.
引用
收藏
页码:1167 / 1176
页数:10
相关论文
共 33 条
  • [21] EFFECT OF LOW-FREQUENCY FATIGUE ON HUMAN-MUSCLE STRENGTH AND FATIGABILITY DURING SUBSEQUENT STIMULATED ACTIVITY
    STOKES, MJ
    EDWARDS, RHT
    COOPER, RG
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1989, 59 (04) : 278 - 283
  • [22] Kilohertz and Low-Frequency Electrical Stimulation With the Same Pulse Duration Have Similar Efficiency for Inducing Isometric Knee Extension Torque and Discomfort
    Medeiros, Flavia Vanessa
    Bottaro, Martim
    Vieira, Amilton
    Lucas, Tiago Pires
    Modesto, Karenina Arrais
    Bo, Antonio Padilha L.
    Cipriano, Gerson, Jr.
    Babault, Nicolas
    Quagliotti Durigan, Joao Luiz
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2017, 96 (06) : 388 - 394
  • [23] Effects of static and low-frequency alternating magnetic fields on the ionic electrolytic currents of glutamic acid aqueous solutions
    Alberto, D.
    Busso, L.
    Crotti, G.
    Gandini, M.
    Garfagnini, R.
    Giudici, P.
    Gnesi, I.
    Manta, F.
    Piragino, G.
    ELECTROMAGNETIC BIOLOGY AND MEDICINE, 2008, 27 (01) : 25 - 39
  • [24] THE EFFECT OF LOW-FREQUENCY FATIGUE ON ENDURANCE EXERCISE IN THE STERNOMASTOID MUSCLE OF NORMAL HUMANS
    EFTHIMIOU, J
    BELMAN, MJ
    HOLMAN, RAE
    EDWARDS, RHT
    SPIRO, SG
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1986, 133 (04): : 667 - 671
  • [25] Effect of very low pulsed direct currents at high frequency on the return of neck tension in broilers
    Wotton, SB
    Wilkins, LJ
    VETERINARY RECORD, 1999, 145 (14) : 393 - 396
  • [26] RANDOM TELEGRAPH SIGNAL CURRENTS AND LOW-FREQUENCY NOISE IN JUNCTION FIELD-EFFECT TRANSISTORS
    KANDIAH, K
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1994, 41 (11) : 2006 - 2015
  • [27] Fatigue Effect on Low-Frequency Force Fluctuations and Muscular Oscillations during Rhythmic Isometric Contraction
    Lin, Yen-Ting
    Kuo, Chia-Hua
    Hwang, Ing-Shiou
    PLOS ONE, 2014, 9 (01):
  • [28] DISTURBING INFLUENCE OF LOW-FREQUENCY ALTERNATING CURRENTS ON ASYNCHRONOUS AND SYNCHRONOUS ELECTRIC PACEMAKER SYSTEMS DURING USE OF ELECTROSURGICAL APPARATUS
    SCHWINGSHACKL, H
    MAUSER, R
    AMOR, H
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1971, 101 (02) : 46 - +
  • [29] THE EFFECT OF LOW-FREQUENCY AUDITORY-STIMULATION AND HIGH-FREQUENCY MUSCLE VIBRATION ON ISOMETRIC WRIST EXTENSOR STRENGTH
    PRIESTLEY, CL
    ALABAMA JOURNAL OF MEDICAL SCIENCES, 1980, 17 (02): : 141 - 141
  • [30] EFFECTS OF ALTERNATING MAGNETIC-FIELDS AND LOW-FREQUENCY ELECTRIC CURRENTS ON HUMAN-SKIN BLOOD-FLOW
    UENO, S
    LOVSUND, P
    OBERG, PA
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1986, 24 (01) : 57 - 61