Label-Free Immunosensor for the Determination of Microcystin-LR in Water

被引:6
|
作者
Almeida de Oliveira, Ravila [1 ]
Zanato, Nicole [1 ]
Cruz Vieira, Iolanda [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Chem, Lab Biosensors, BR-88040900 Florianopolis, SC, Brazil
关键词
Microcystin-LR; Label-free immunosensor; Nanoparticles; FREE ELECTROCHEMICAL IMMUNOSENSOR; RAPID DETECTION; NANOPARTICLES; CYANOBACTERIA; NANOCLUSTERS; PRINCIPLES; GRAPHENE; FACILE; TOXINS; TOOL;
D O I
10.1002/elan.202060041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the development of a label-free electrochemical immunosensor based on polyethyleneimine-stabilized magnetite nanoparticles (MGNnP-PEI) for the determination of microcystin-LR (MC-LR). MGNnP-PEI was immobilized on the glassy carbon electrode (GCE) surface and employed as a platform for anchorage of the anti-MC-LR. Hydroquinone in solution was used as a redox probe. After optimization, the immunosensor exhibited a linear response to MC-LR concentrations in the range of 0.1 to 500 ng mL(-1)with a calculated detection limit of 0.053 ng mL(-1). The immunosensor was satisfactorily applied in the quantification of MC-LR in a water sample collected from a freshwater lagoon.
引用
收藏
页码:2166 / 2173
页数:8
相关论文
共 50 条
  • [11] Label-free capacitive immunosensor for microcystin-LR using self-assembled thiourea monolayer incorporated with Ag nanoparticles on gold electrode
    Loyprasert, Suchera
    Thavarungkul, Panote
    Asawatreratanakul, Punnee
    Wongkittisuksa, Booncharoen
    Limsakul, Chusak
    Kanatharana, Proespichaya
    BIOSENSORS & BIOELECTRONICS, 2008, 24 (01): : 78 - 86
  • [12] A layer-by-layer assembly label-free electrochemical immunosensor for the detection of microcystin-LR based on CHIT/PAMAM dendrimer/silver nanocubes
    Fu, Xuewen
    Zhao, Chunling
    Liu, Xiaohai
    Zhao, Jinhang
    Niu, Xiaofang
    Zheng, Li
    Yang, Yunhui
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2016, 96 (03) : 284 - 297
  • [13] Label-free identification of trace microcystin-LR with surface-enhanced Raman scattering spectra
    He, Shixuan
    Xie, Wanyi
    Fang, Shaoxi
    Zhou, Daming
    Djebbi, Khouloud
    Zhang, Zhiyou
    Du, Jinglei
    Du, Chunlei
    Wang, Deqiang
    TALANTA, 2019, 195 : 401 - 406
  • [14] Label-free aptamer-based detection of microcystin-LR using a microcantilever array biosensor
    Zhang, Guanping
    Li, Chao
    Wu, Shangquan
    Zhang, Qingchuan
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 260 : 42 - 47
  • [15] Label-Free Extended Gate Field-Effect Transistor for Sensing Microcystin-LR in Freshwater Samples
    Nandanwar, Sondavid
    Lee, Songyi
    Park, Myeongkee
    Kim, Hak Jun
    SENSORS, 2025, 25 (05)
  • [16] Label-Free Voltammetric Aptasensor for the Sensitive Detection of Microcystin-LR Using Graphene-Modified Electrodes
    Eissa, Shimaa
    Ng, Andy
    Siaj, Mohamed
    Zourob, Mohammed
    ANALYTICAL CHEMISTRY, 2014, 86 (15) : 7551 - 7557
  • [17] Portable optical immunosensor for highly sensitive detection of microcystin-LR in water samples
    Long, F.
    He, M.
    Zhu, A. N.
    Shi, H. C.
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (08): : 2346 - 2351
  • [18] Determination of Microcystin-LR in Water from Lake Tai, China
    Xiao, Fu-Gang
    Zhao, Xiao-Lian
    Tang, Jian
    Gu, Xiao-Hong
    Zhang, Jing-Ping
    Niu, Wei-Min
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2009, 82 (02) : 230 - 233
  • [19] Determination of microcystin-LR, employing aptasensors
    Bostan, Hasan Badie
    Taghdisi, Seyed Mohammad
    Bowen, Jenna L.
    Demertzis, Nikolaos
    Rezaee, Ramin
    Panahi, Yunes
    Tsatsakis, Aristidis M.
    Karimi, Gholamreza
    BIOSENSORS & BIOELECTRONICS, 2018, 119 : 110 - 118
  • [20] Determination of Microcystin-LR in Water from Lake Tai, China
    Fu-Gang Xiao
    Xiao-Lian Zhao
    Jian Tang
    Xiao-Hong Gu
    Jing-Ping Zhang
    Wei-Min Niu
    Bulletin of Environmental Contamination and Toxicology, 2009, 82 : 230 - 233