A layer-by-layer assembly label-free electrochemical immunosensor for the detection of microcystin-LR based on CHIT/PAMAM dendrimer/silver nanocubes

被引:2
|
作者
Fu, Xuewen [1 ]
Zhao, Chunling [1 ]
Liu, Xiaohai [2 ]
Zhao, Jinhang [1 ]
Niu, Xiaofang [1 ]
Zheng, Li [1 ]
Yang, Yunhui [1 ]
机构
[1] Yunnan Normal Univ, Coll Chem & Chem Engn, Kunming, Peoples R China
[2] Yunnan Inst Environm Sci, Environm Anal & Testing Ctr, Kunming, Peoples R China
基金
中国国家自然科学基金;
关键词
label-free immunosensor; silver nanocubes; microcystins-LR; G4-polyamidoamine dendrimer; SILVER NANOPARTICLES; SENSITIVE DETECTION; RAPID DETECTION; SAMPLES; IMMUNOASSAY; BIOSENSOR; ELECTRODE; WATER; NANOTECHNOLOGY; AMPLIFICATION;
D O I
10.1080/03067319.2016.1150460
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Utilising the affinity and high combination ability between silver nanocubes and amino group (-NH2), a novel electrochemical immunosensor was constructed for the ultrasensitive detection of microcystin-LR (MC-LR) based on G4-polyamidoamine (PAMAM) dendrimer and Ag nanocubes as immobilised substrate of anti-MC-LR. G4-PAMAM dendrimers were covalently bound on the chitosan (CHIT) - modified electrode by glutaraldehyde (GA), providing abundant amino groups to absorb much more Ag nanocubes comparing without using PAMAM. Subsequently, antibodies of MC-LR were immobilised with highly dense through Ag-NH2. K3Fe(CN)(6)/K4Fe(CN)(6) was used as electroactive redox probe. Ag nanocubes/PAMAM can enhance the antibody loading amount, which would bind more MC-LR and hinder the electron transfer of K3Fe(CN)(6)/K4Fe(CN)(6). Differential pulse voltammetry (DPV) was employed to evaluate the analytical performance of the fabricated signal-off immunosensor. The response current had negative correlation with the concentration of MC-LR. The linear range covered was from 0.05ng/mL to 25 mu g/mL with detection limit (DL) of 0.017ng/mL at 3 sigma. The proposed approach showed high specificity for the detection of MC-LR, with acceptable reproducibility, stability and reliability. Compared with the enzyme-linked immunoassay (ELISA) method by analyzing real water samples from Dian Lake, this immunosensor revealed acceptable accuracy with a relative error of 12.7%, indicating a potential alternative method for MC-LR detection in water sample.
引用
收藏
页码:284 / 297
页数:14
相关论文
共 50 条
  • [1] Microcystin-LR label-free immunosensor based on exfoliated graphite nanoplatelets and silver nanoparticles
    Zanato, Nicole
    Talamini, Lucas
    Silva, Tania Regina
    Vieira, Iolanda Cruz
    TALANTA, 2017, 175 : 38 - 45
  • [2] Label-Free Immunosensor for the Determination of Microcystin-LR in Water
    Almeida de Oliveira, Ravila
    Zanato, Nicole
    Cruz Vieira, Iolanda
    ELECTROANALYSIS, 2020, 32 (10) : 2166 - 2173
  • [3] A label-free electrochemical immunosensor based on multi-functionalized graphene oxide for ultrasensitive detection of microcystin-LR
    YunXia Hu
    Fang Shang
    Yuan Liu
    Sui Wang
    Yufang Hu
    Zhiyong Guo
    Chemical Papers, 2018, 72 : 71 - 79
  • [4] A label-free electrochemical immunosensor based on multi-functionalized graphene oxide for ultrasensitive detection of microcystin-LR
    Hu, YunXia
    Shang, Fang
    Liu, Yuan
    Wang, Sui
    Hu, Yufang
    Guo, Zhiyong
    CHEMICAL PAPERS, 2018, 72 (01) : 71 - 79
  • [5] A SIMPLE, HIGHLY SENSITIVE, AND LABEL-FREE IMPEDIMETRIC IMMUNOSENSOR FOR DETECTION OF MICROCYSTIN-LR IN WATER
    Sun, Xiulan
    Shi, Hui
    Wang, Hongxin
    Xiao, Liwen
    Li, Luning
    ANALYTICAL LETTERS, 2010, 43 (04) : 533 - 544
  • [6] Label-Free Electrical Immunosensor for Highly Sensitive and Specific Detection of Microcystin-LR in Water Samples
    Tan, Feng
    Saucedo, Nuvia Maria
    Ramnani, Pankaj
    Mulchandani, Ashok
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (15) : 9256 - 9263
  • [7] Sensitive Detection of Microcystin-LR by Using a Label-Free Electrochemical Immunosensor Based on Au Nanoparticles/Silicon Template/Methylene Blue Nanocomposite
    Fu, Xuewen
    Feng, Yajuan
    Niu, Sipeng
    Zhao, Chunling
    Yang, Minghui
    Yang, Yunhui
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2013, 13 (12) : 8245 - 8252
  • [8] Determination of microcystin-LR in water by a label-free aptamer based electrochemical impedance biosensor
    Lin, Zhenyu
    Huang, Huiming
    Xu, Yixiang
    Gao, Xiaoyao
    Qiu, Bin
    Chen, Xi
    Chen, Guonan
    TALANTA, 2013, 103 : 371 - 374
  • [9] An Enzyme-free and Label-free Fluorescent Probe for Detection of Microcystin-LR Based on Circular DNA-Silver Nanoclusters
    Yang X.
    Lai Y.
    Li Q.
    Zhang Y.
    Wang H.
    Pang P.
    Yang W.
    Gaodeng Xuexiao Huaxue Xuebao/Chemical Journal of Chinese Universities, 2021, 42 (12): : 3600 - 3605
  • [10] An Enzyme-free and Label-free Fluorescent Probe for Detection of Microcystin-LR Based on Circular DNA-Silver Nanoclusters
    Yang Xinjie
    Lai Yanqiong
    Li Qiuyang
    Zhang Yanli
    Wang Hongbin
    Pang Pengfei
    Yang Wenrong
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2021, 42 (12): : 3600 - 3605