Optimization of the structure of an electromagnetic calorimeter with longitudinal arrangement of absorbing and scintillating layers

被引:0
|
作者
Korablev, AV [1 ]
机构
[1] Inst High Energy Phys, Protvino 142284, Moscow Oblast, Russia
关键词
Physical Chemistry; Calorimeter; Geometric Parameter; Energy Resolution; Angular Dependence;
D O I
10.1023/A:1014579605149
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A new layout of the absorbing and scintillating layers is proposed in order to suppress the channeling effect in an electromagnetic calorimeter where these layers are parallel to the beam. The energy resolution of this calorimeter is estimated for different geometric parameters. A weaker angular dependence is observed at angles >30 mrad.
引用
收藏
页码:6 / 8
页数:3
相关论文
共 50 条
  • [41] The Structure Optimization and Magnetic Leakage Analysis of a Electromagnetic Brake with Two Layers windings
    Shang, Jing
    Ran, Xiaohe
    Liu, Cheng
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 1978 - 1982
  • [42] ENERGY RESOLUTION AND LONGITUDINAL SHOWER DEVELOPMENT IN A SI/W ELECTROMAGNETIC CALORIMETER
    BARBIELLINI, G
    CECCHET, G
    HEMERY, JY
    LEMEILLEUR, F
    LEROY, C
    LEVMAN, G
    RANCOITA, PG
    SEIDMAN, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 235 (01): : 55 - 60
  • [43] Monte Carlo study of the electromagnetic calorimeter optimization for MPD/NICA
    Marinova, B.
    Javadov, N.
    Tyapkin, I.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2015, 47 : 248 - 251
  • [44] A tungsten/scintillating fiber electromagnetic calorimeter prototype for a high-rate muon (g-2) experiment
    McNabb, R.
    Blackburn, J.
    Crnkovic, J. D.
    Hertzog, D. W.
    Kiburg, B.
    Kunkle, J.
    Thorsland, E.
    Webber, D. M.
    Lynch, K. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 602 (02): : 396 - 402
  • [45] Influence of the electromagnetic parameters on the surface wave attenuation in thin absorbing layers
    Li, Yinrui
    Li, Dongmeng
    Wang, Xian
    Nie, Yan
    Gong, Rongzhou
    AIP ADVANCES, 2018, 8 (05)
  • [46] ENERGY RESOLUTION AND LONGITUDINAL SHOWER DEVELOPMENT IN A Si/W ELECTROMAGNETIC CALORIMETER.
    Barbiellini, G.
    Cecchet, G.
    Hemery, J.Y.
    Lemeilleur, F.
    Leroy, C.
    Levman, G.
    Rancoita, P.G.
    Seidman, A.
    Nuclear instruments and methods in physics research, 1985, A235 (01): : 55 - 60
  • [47] Development, optimization, and calibration of an active electromagnetic calorimeter for pulsed radiation spectrometry
    Stransky, V.
    Istokskaia, V.
    Versaci, R.
    Giuffrida, L.
    Cimmino, A.
    Margarone, D.
    Olsovcova, V.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (08)
  • [48] OPTIMIZATION OF RESPONSE OF BGO SECTORS FOR A 4-PI ELECTROMAGNETIC CALORIMETER
    ZUCCHIATTI, A
    CASTOLDI, M
    GERVINO, G
    TERZI, F
    ANGHINOLFI, M
    BIANCHI, N
    CASANO, L
    CORVISIERO, P
    DANGELO, A
    DESANCTIS, E
    GIROLAMI, B
    SANDRI, PL
    LUCHERINI, V
    MAZZASCHI, L
    MOKEEV, V
    MUCCIFORA, V
    PICOZZA, P
    POLLI, E
    REOLON, AR
    RICCO, G
    RIPANI, M
    ROSSI, P
    SANZONE, M
    SCHAERF, C
    TAIUTI, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 317 (03): : 492 - 497
  • [49] The low noise L1 trigger of the H1 lead/scintillating-fibre electromagnetic calorimeter
    Moreau, F
    NUCLEAR PHYSICS B, 1998, : 132 - 136
  • [50] A SCINTILLATING TILE FIBER SYSTEM FOR A HIGH-ENERGY CALORIMETER WITH HIGH LIGHT YIELD AND UNIFORM LONGITUDINAL AND TRANSVERSE RESPONSE
    ASAKAWA, T
    FUJIWARA, I
    KIM, S
    KONDO, K
    MOGAMI, T
    MUNAKATA, S
    SATO, H
    TOYODA, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 340 (03): : 458 - 465