Optimization of the structure of an electromagnetic calorimeter with longitudinal arrangement of absorbing and scintillating layers

被引:0
|
作者
Korablev, AV [1 ]
机构
[1] Inst High Energy Phys, Protvino 142284, Moscow Oblast, Russia
关键词
Physical Chemistry; Calorimeter; Geometric Parameter; Energy Resolution; Angular Dependence;
D O I
10.1023/A:1014579605149
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A new layout of the absorbing and scintillating layers is proposed in order to suppress the channeling effect in an electromagnetic calorimeter where these layers are parallel to the beam. The energy resolution of this calorimeter is estimated for different geometric parameters. A weaker angular dependence is observed at angles >30 mrad.
引用
收藏
页码:6 / 8
页数:3
相关论文
共 50 条
  • [31] Performance of an electromagnetic lead/scintillating-fibre calorimeter for the H1 detector
    Nicholls, T
    Hajduk, L
    Janczur, W
    Rybicki, K
    Claxton, B
    Dowdell, J
    Deckers, H
    Deckers, T
    Dirkmann, M
    Hutte, M
    Hutter, M
    Kolanoski, H
    Poschl, R
    Schuhmacher, A
    Wacker, K
    Walther, A
    Wegener, D
    Wenk, T
    Cozzika, G
    Laforge, B
    Laporte, JF
    Perez, E
    Royon, C
    Villet, G
    Appuhn, RD
    Arndt, C
    Barschke, R
    Buchholz, R
    Georlach, U
    Korbel, V
    Lehner, F
    Meyer, A
    Muller, G
    Steiner, H
    Weber, M
    Ferencei, J
    Janoth, J
    Meier, K
    Schleif, S
    Stiewe, J
    Zuber, K
    Dau, WD
    Bruncko, D
    Krivan, F
    Maracek, R
    Murin, P
    Spalek, J
    Eisenhandler, E
    Landon, M
    Jonsson, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 374 (02): : 149 - 156
  • [32] Dead cell and side leakage correction for a lead-scintillating fiber electromagnetic calorimeter
    张诚
    李祖豪
    唐志成
    Suzan Basegmez du Pree
    张劭文
    王薛强
    杨民
    陈国明
    陈和生
    Chinese Physics C, 2016, 40 (09) : 137 - 141
  • [33] Dead cell and side leakage correction for a lead-scintillating fiber electromagnetic calorimeter
    Zhang, Cheng
    Li, Zu-Hao
    Tang, Zhi-Cheng
    du Pree, Suzan Basegmez
    Zhang, Shao-Wen
    Wang, Xue-Qiang
    Yang, Min
    Chen, Guo-Ming
    Chen, He-Sheng
    CHINESE PHYSICS C, 2016, 40 (09)
  • [34] Dead cell and side leakage correction for a lead-scintillating fiber electromagnetic calorimeter
    张诚
    李祖豪
    唐志成
    Suzan Basegmez du Pree
    张劭文
    王薛强
    杨民
    陈国明
    陈和生
    Chinese Physics C, 2016, (09) : 137 - 141
  • [35] Longitudinal leakage correction of uniformly sampling electromagnetic calorimeter
    Li, ZH
    Chen, GM
    Chen, G
    Yang, CG
    Yang, M
    Wang, XB
    Zhang, SH
    Yang, ZY
    Lü, YS
    Chen, HS
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (11): : 1188 - 1192
  • [36] Design of a 2 × 2 scintillating tile package for the SDC barrel electromagnetic tile/fiber calorimeter
    Hara, K.
    Kim, S.
    Maekoba, H.
    Minato, H.
    Miyamoto, Y.
    Nakano, I.
    Okabe, M.
    Seiya, Y.
    Takano, T.
    Takikawa, K.
    Yasuoka, K.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 373 (03): : 347 - 357
  • [37] AN ELECTROMAGNETIC CALORIMETER PROTOTYPE MODULE USING SCINTILLATING FIBERS IMMERSED IN A BI-PB ALLOY
    BLUMENFELD, H
    BOURDINAUD, M
    BURMEISTER, H
    CESTER, R
    CHECCHIA, P
    ZUMERLE, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (03): : 518 - 521
  • [38] Optimization of response of BGO sectors for a 4π electromagnetic calorimeter
    Zucchiatti, A.
    Castoldi, M.
    Gervino, G.
    Terzi, F.
    Anghinolfi, M.
    Bianchi, N.
    Casano, L.
    Corvisiero, P.
    D'Angelo, A.
    De Sanctis, E.
    Girolami, B.
    Levi Sandri, P.
    Lucherini, V.
    Mazzaschi, L.
    Mokeev, V.
    Muccifora, V.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992, A317 (03) : 492 - 497
  • [39] The KLOE lead-scintillating fiber electromagnetic calorimeter for detecting low energy particles at DAΦNE
    Di Domenico, A
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2000, : 73 - 80
  • [40] Design of a 2 x 2 scintillating tile package for the SDC barrel electromagnetic tile/fiber calorimeter
    Hara, K
    Kim, S
    Maekoba, H
    Minato, H
    Miyamoto, Y
    Nakano, I
    Okabe, M
    Seiya, Y
    Takano, T
    Takikawa, K
    Yasuoka, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 373 (03): : 347 - 357