Long-term outcomes after valve replacement for low-gradient aortic stenosis - Impact of prosthesis-patient mismatch

被引:100
|
作者
Kulik, Alexander
Burwash, Ian G.
Kapila, Varun
Mesana, Thierry G.
Ruel, Marc
机构
[1] Univ Ottawa, Inst Heart, Div Cardiac Surg, Ottawa, ON K1Y 4W7, Canada
[2] Univ Ottawa, Div Cardiol, Ottawa, ON K1Y 4W7, Canada
[3] Univ Ottawa, Dept Epidemiol, Ottawa, ON K1Y 4W7, Canada
关键词
aortic stenosis; aortic valve replacement; prosthesis-patient mismatch;
D O I
10.1161/CIRCULATIONAHA.105.001180
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - The long-term outcomes of patients with low-gradient aortic stenosis (LGAS) after aortic valve replacement (AVR) are poorly defined. The purpose of this study was to define the long-term outcomes of LGAS patients after AVR and to evaluate the potential impact of prosthesis-patient mismatch (PPM) in these patients. Methods and Results - A cohort of 664 patients undergoing AVR for aortic stenosis after 1990 were followed-up prospectively with annual clinical assessment and echocardiography (total follow-up 3447 patient-years; mean follow- up 5.2 +/- 3.3 years). LGAS was defined as an aortic valve area < 1.2 cm(2), a mean transvalvular pressure gradient < 40 mm Hg, and a left ventricular (LV) ejection fraction < 50%, and was present in 79 patients. Rates and correlates of survival, freedom from congestive heart failure (CHF), and LV mass regression after AVR were determined using multivariate regression methods. Ten-year survival and freedom from CHF after AVR were 72.7 +/- 7.5% and 68.2 +/- 9.5%, respectively, for patients with LGAS, compared with 89.6 +/- 1.8% and 84.1 +/- 4.2% for patients without LGAS (hazard ratio [HR] for death and postoperative CHF, 3.1 +/- 1.1 and 2.7 +/- 0.9, respectively; P < 0.01). In LGAS patients, PPM, defined as an indexed effective orifice area <= 0.85 cm(2)/ m(2), was independently associated with increased rates of CHF ( HR, 3.6 +/- 2.2; P = 0.039), impaired LV mass regression (P = 0.037), and a trend toward increased late mortality (HR, 3.0 +/- 1.9; P = 0.084). Conclusions - Patients with LGAS have worse long-term outcomes after AVR compared with patients without LGAS. PPM adversely affects the long-term outcomes of LGAS patients and should be avoided in this population.
引用
收藏
页码:I553 / I558
页数:6
相关论文
共 50 条
  • [31] Impact of prosthesis-patient mismatch on mitral regurgitation after aortic valve replacement
    Unger, P.
    Magne, J.
    Eynden, F. Vanden
    Plein, D.
    Van Camp, G.
    Pasquet, A.
    Cosyns, B.
    Dedobbeleer, C.
    Lancellotti, P.
    HEART, 2010, 96 (20) : 1627 - 1632
  • [32] The relevance of prosthesis-patient mismatch after aortic valve replacement
    Pibarot, Philippe
    Dumesnil, Jean G.
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (12): : 764 - 765
  • [33] Prosthesis-patient mismatch is associated with long-term mortality following surgical aortic valve replacement
    Mazine, A.
    Chu, A.
    Rocha, R.
    Yau, T. M.
    Rao, V
    Pibarot, P.
    Lee, D. S.
    David, T. E.
    Ouzounian, M.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [34] Prosthesis-patient mismatch is associated with long-term mortality following surgical aortic valve replacement
    Mazine, A.
    Chu, A.
    Rocha, R.
    Yau, T. M.
    Rao, V
    Pibarot, P.
    Lee, D. S.
    David, T. E.
    Ouzounian, M.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [35] Sex difference in Prosthesis-Patient Mismatch after Surgical Aortic Valve Replacement and long-term clinical outcome
    Springhetti, Paolo
    Abdoun, Kathia
    Dumont, Eric
    Dagenais, Francois
    Kalavrouziotis, Dimitri
    Mohammadi, Siamak
    Pibarot, Philippe
    Clavel, Marie-Annick
    CIRCULATION, 2024, 150
  • [36] Patient prosthesis mismatch and short-term outcomes after aortic valve replacement for aortic stenosis
    Valencia Serrano, F.
    Gomez-Doblas, J. J.
    Caballero-Borrego, J.
    Cabrera-Bueno, F.
    Porras, C.
    Olalla-Mercade, E.
    De Teresa Galvan, E.
    EUROPEAN HEART JOURNAL, 2010, 31 : 950 - 950
  • [37] Prosthesis-patient mismatch after transcatheter aortic valve replacement: prevalence and medium term prognostic impact
    Leon del Pino, Maria del Carmen
    Ruiz Ortiz, Martin
    Delgado Ortega, Monica
    Sanchez Fernandez, Jose
    Ferreiro Quero, Carlos
    Duran Jimenez, Enrique
    Romero Moreno, Miguel
    Segura Saint-Gerons, Jose
    Ojeda Pineda, Soledad
    Pan Alvarez-Ossorio, Manuel
    Mesa Rubio, Dolores
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (05): : 827 - 836
  • [38] Prosthesis-patient mismatch after transcatheter aortic valve replacement: prevalence and medium term prognostic impact
    María del Carmen León del Pino
    Martín Ruíz Ortiz
    Mónica Delgado Ortega
    José Sánchez Fernández
    Carlos Ferreiro Quero
    Enrique Durán Jiménez
    Miguel Romero Moreno
    José Segura Saint-Gerons
    Soledad Ojeda Pineda
    Manuel Pan Álvarez-Ossorio
    Dolores Mesa Rubio
    The International Journal of Cardiovascular Imaging, 2019, 35 : 827 - 836
  • [39] Incidence and Prognosis of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement for Bicuspid Aortic Stenosis
    Yamanaka, Futoshi
    Shishido, Koki
    Moriyama, Noriaki
    Ochiai, Tomoki
    Miyashita, Hirokazu
    Yokoyama, Hiroaki
    Sugiyama, Yoichi
    Yashima, Fumiaki
    Ohno, Yohei
    Nishina, Hidetaka
    Izumo, Masaki
    Asami, Masahiko
    Naganuma, Toru
    Mizutani, Kazuki
    Yamawaki, Masahiro
    Tada, Norio
    Shirai, Shinichi
    Noguchi, Masahiko
    Ueno, Hiroshi
    Takagi, Kensuke
    Watanabe, Yusuke
    Yamamoto, Masanori
    Saito, Shigeru
    Hayashida, Kentaro
    JACC-CARDIOVASCULAR INTERVENTIONS, 2025, 18 (04) : 492 - 502
  • [40] VALVE PROSTHESIS-PATIENT MISMATCH - A LONG-TERM SEQUELA
    RAHIMTOOLA, SH
    MURPHY, E
    BRITISH HEART JOURNAL, 1981, 45 (03): : 331 - 335