Incidence and Prognosis of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement for Bicuspid Aortic Stenosis

被引:2
|
作者
Yamanaka, Futoshi [1 ]
Shishido, Koki [1 ]
Moriyama, Noriaki [1 ]
Ochiai, Tomoki [1 ]
Miyashita, Hirokazu [1 ]
Yokoyama, Hiroaki [1 ]
Sugiyama, Yoichi [1 ]
Yashima, Fumiaki [2 ]
Ohno, Yohei [3 ]
Nishina, Hidetaka [4 ]
Izumo, Masaki [5 ]
Asami, Masahiko [6 ]
Naganuma, Toru [7 ]
Mizutani, Kazuki [8 ]
Yamawaki, Masahiro [9 ]
Tada, Norio [10 ]
Shirai, Shinichi [11 ]
Noguchi, Masahiko [12 ]
Ueno, Hiroshi [13 ]
Takagi, Kensuke [14 ]
Watanabe, Yusuke [15 ]
Yamamoto, Masanori [16 ,17 ,18 ]
Saito, Shigeru [1 ]
Hayashida, Kentaro [19 ]
机构
[1] Shonan Kamakura Gen Hosp, Dept Cardiol, Okamoto 1370-1, Kamakura 2478533, Japan
[2] Saiseikai Utsunomiya Hosp, Dept Cardiol, Utsunomiya, Tochigi, Japan
[3] Tokai Univ, Sch Med, Dept Cardiol, Isehara, Japan
[4] Tsukuba Med Ctr Hosp, Dept Cardiol, Tsukuba, Japan
[5] St Marianna Univ, Dept Cardiol, Kawasaki, Japan
[6] Mitsui Mem Hosp, Div Cardiol, Tokyo, Japan
[7] New Tokyo Hosp, Dept Cardiol, Matsudo, Japan
[8] Kindai Univ, Fac Med, Div Cardiol, Higashiosaka, Osaka, Japan
[9] Saiseikai Yokohama City Eastern Hosp, Dept Cardiol, Yokohama, Japan
[10] Sendai Kousei Hosp, Dept Cardiol, Sendai, Japan
[11] Kokura Mem Hosp, Dept Cardiol, Kokura, Japan
[12] Tokyo Bay Urayasu Ichikawa Med Ctr, Dept Cardiol, Urayasu, Japan
[13] Toyama Univ, Dept Pediat, Toyama 9300194, Japan
[14] Natl Cerebral & Cardiovasc Ctr, Dept Cardiol, Osaka, Japan
[15] Teikyo Univ, Sch Med, Dept Cardiol, Tokyo, Japan
[16] Toyohashi Heart Ctr, Dept Cardiol, Toyohashi, Japan
[17] Nagoya Heart Ctr, Dept Cardiol, Nagoya, Japan
[18] Gifu Heart Ctr, Dept Cardiol, Gifu, Japan
[19] Keio Univ, Sch Med, Dept Cardiol, Tokyo, Japan
关键词
all-cause mortality; bicuspid aortic valve; long-term mortality; prosthesis- patient mismatch; transcatheter aortic valve replacement; OUTCOMES; CLASSIFICATION; ASSOCIATION; IMPACT; TAVI;
D O I
10.1016/j.jcin.2024.10.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce. OBJECTIVES This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS. METHODS In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry. We analyzed 7,051 patients (median age = 85 years, 68.4% women) and identified 503 (7.1%) with bicuspid AS. We compared the incidence of PPM and long-term mortality in 497 patients with and 497 without bicuspid AS after oneto-one propensity score matching analysis. RESULTS Among the 7,051 patients, moderate and severe PPM were observed in 756 (10.7%) and 92 (1.3%) patients, respectively. Upon Kaplan-Meier curve analysis of the overall cohort, severe PPM appeared to be associated with longterm mortality (log-rank test, P = 0.065). After propensity score matching analysis, moderate and severe PPM were more frequently observed among patients with tricuspid AS than patients with bicuspid AS (moderate PPM, 11.7% vs 4.4%; severe PPM, 1.4% vs 1.0%; P = 0.0001). CONCLUSIONS Severe PPM appeared to be associated with all-cause mortality. Moderate and severe PPM were more frequently observed in patients with tricuspid AS than patients with bicuspid AS. (JACC Cardiovasc Interv. 2025;18:492-502) (c) 2025 by the American College of Cardiology Foundation.
引用
收藏
页码:492 / 502
页数:11
相关论文
共 50 条
  • [1] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Herrmann, Howard C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2183 - 2185
  • [2] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Sa, Michel Pompeu
    Jacquemyn, Xander
    Van den Eynde, Jef
    Tasoudis, Panagiotis
    Dokollari, Aleksander
    Torregrossa, Gianluca
    Sicouri, Serge
    Clavel, Marie-Annick
    Pibarot, Philippe
    Ramlawi, Basel
    JACC-CARDIOVASCULAR IMAGING, 2022, 16 (03) : 298 - 310
  • [3] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Levesque, Thomas
    Eltchaninoff, Helene
    Chabannes, Romain
    Barbe, Thomas
    Dosseh, Olivier
    Tron, Christophe
    Bettinger, Nicolas
    Bouhzam, Najime
    Hemery, Thibaut
    le Pessec, Guillaume
    Fauvel, Charles
    Cribier, Alain
    Pibarot, Philippe
    Durand, Eric
    CANADIAN JOURNAL OF CARDIOLOGY, 2024, 40 (01) : 113 - 122
  • [4] Prosthesis-patient mismatch after surgical aortic valve replacement in patients with aortic stenosis
    Kim, Hee Jung
    Kim, Ho Jin
    Kim, Joon Bum
    Jung, Sung-Ho
    Choo, Suk Jung
    Chung, Cheol Hyun
    Lee, Jae Won
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 31 (02) : 152 - 157
  • [5] Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis
    Astudillo, Luis M.
    Santana, Orlando
    Urbandt, Pablo A.
    Benjo, Alexandre M.
    Elkayam, Lior U.
    Nascimento, Francisco O.
    Lamas, Gervasio A.
    Lamelas, Joseph
    CLINICS, 2012, 67 (01) : 55 - 60
  • [6] Overcoming prosthesis-patient mismatch with transcatheter aortic valve replacement
    Grubb, Kendra J.
    Tom, Stephanie K.
    Sultan, Ibrahim
    Sa, Michel Pompeu
    ANNALS OF CARDIOTHORACIC SURGERY, 2024, 13 (03) : 236 - 243
  • [7] Prosthesis-Patient Mismatch in the Transcatheter Aortic Valve Replacement Era
    Tuzcu, E. Murat
    Oezkan, Alper
    Kapadia, Samir R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1919 - 1922
  • [8] Prosthesis-patient mismatch in transcatheter and surgical aortic valve replacement
    Hahn, Rebecca T.
    Pibarot, Philippe
    ANNALS OF CARDIOTHORACIC SURGERY, 2024, 13 (03) : 211 - 223
  • [9] Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement
    Abbas, Amr E.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (01) : 138 - 138
  • [10] Different incidence and implications of prosthesis-patient mismatch after aortic valve replacement for aortic insufficiency versus aortic stenosis
    Price, J.
    Chan, V.
    Kulik, A.
    Ressler, L.
    Bedard, P.
    Mesana, T. G.
    Ruel, M.
    CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 : 133C - 133C