Incidence and Prognosis of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement for Bicuspid Aortic Stenosis

被引:2
|
作者
Yamanaka, Futoshi [1 ]
Shishido, Koki [1 ]
Moriyama, Noriaki [1 ]
Ochiai, Tomoki [1 ]
Miyashita, Hirokazu [1 ]
Yokoyama, Hiroaki [1 ]
Sugiyama, Yoichi [1 ]
Yashima, Fumiaki [2 ]
Ohno, Yohei [3 ]
Nishina, Hidetaka [4 ]
Izumo, Masaki [5 ]
Asami, Masahiko [6 ]
Naganuma, Toru [7 ]
Mizutani, Kazuki [8 ]
Yamawaki, Masahiro [9 ]
Tada, Norio [10 ]
Shirai, Shinichi [11 ]
Noguchi, Masahiko [12 ]
Ueno, Hiroshi [13 ]
Takagi, Kensuke [14 ]
Watanabe, Yusuke [15 ]
Yamamoto, Masanori [16 ,17 ,18 ]
Saito, Shigeru [1 ]
Hayashida, Kentaro [19 ]
机构
[1] Shonan Kamakura Gen Hosp, Dept Cardiol, Okamoto 1370-1, Kamakura 2478533, Japan
[2] Saiseikai Utsunomiya Hosp, Dept Cardiol, Utsunomiya, Tochigi, Japan
[3] Tokai Univ, Sch Med, Dept Cardiol, Isehara, Japan
[4] Tsukuba Med Ctr Hosp, Dept Cardiol, Tsukuba, Japan
[5] St Marianna Univ, Dept Cardiol, Kawasaki, Japan
[6] Mitsui Mem Hosp, Div Cardiol, Tokyo, Japan
[7] New Tokyo Hosp, Dept Cardiol, Matsudo, Japan
[8] Kindai Univ, Fac Med, Div Cardiol, Higashiosaka, Osaka, Japan
[9] Saiseikai Yokohama City Eastern Hosp, Dept Cardiol, Yokohama, Japan
[10] Sendai Kousei Hosp, Dept Cardiol, Sendai, Japan
[11] Kokura Mem Hosp, Dept Cardiol, Kokura, Japan
[12] Tokyo Bay Urayasu Ichikawa Med Ctr, Dept Cardiol, Urayasu, Japan
[13] Toyama Univ, Dept Pediat, Toyama 9300194, Japan
[14] Natl Cerebral & Cardiovasc Ctr, Dept Cardiol, Osaka, Japan
[15] Teikyo Univ, Sch Med, Dept Cardiol, Tokyo, Japan
[16] Toyohashi Heart Ctr, Dept Cardiol, Toyohashi, Japan
[17] Nagoya Heart Ctr, Dept Cardiol, Nagoya, Japan
[18] Gifu Heart Ctr, Dept Cardiol, Gifu, Japan
[19] Keio Univ, Sch Med, Dept Cardiol, Tokyo, Japan
关键词
all-cause mortality; bicuspid aortic valve; long-term mortality; prosthesis- patient mismatch; transcatheter aortic valve replacement; OUTCOMES; CLASSIFICATION; ASSOCIATION; IMPACT; TAVI;
D O I
10.1016/j.jcin.2024.10.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce. OBJECTIVES This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS. METHODS In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry. We analyzed 7,051 patients (median age = 85 years, 68.4% women) and identified 503 (7.1%) with bicuspid AS. We compared the incidence of PPM and long-term mortality in 497 patients with and 497 without bicuspid AS after oneto-one propensity score matching analysis. RESULTS Among the 7,051 patients, moderate and severe PPM were observed in 756 (10.7%) and 92 (1.3%) patients, respectively. Upon Kaplan-Meier curve analysis of the overall cohort, severe PPM appeared to be associated with longterm mortality (log-rank test, P = 0.065). After propensity score matching analysis, moderate and severe PPM were more frequently observed among patients with tricuspid AS than patients with bicuspid AS (moderate PPM, 11.7% vs 4.4%; severe PPM, 1.4% vs 1.0%; P = 0.0001). CONCLUSIONS Severe PPM appeared to be associated with all-cause mortality. Moderate and severe PPM were more frequently observed in patients with tricuspid AS than patients with bicuspid AS. (JACC Cardiovasc Interv. 2025;18:492-502) (c) 2025 by the American College of Cardiology Foundation.
引用
收藏
页码:492 / 502
页数:11
相关论文
共 50 条
  • [21] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement Has It Become Obsolete?
    Ternacle, Julien
    Abbas, Amr E.
    Pibarot, Philippe
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (09) : 977 - 980
  • [22] Impact of Measured and Predicted Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Guthoff, Henning
    Abdel-Wahab, Mohamed
    Kim, Won-Keun
    Witberg, Guy
    Wienemann, Hendrik
    Thurow, Maria
    Shamekhi, Jasmin
    Eckel, Clemens
    von der Heide, Ina
    Veulemans, Verena
    Landt, Martin
    Barbanti, Marco
    Finkelstein, Ariel
    Schewel, Jury
    Van Mieghem, Nicolas
    Adrichem, Rik
    Toggweiler, Stefan
    Rheude, Tobias
    Nombela-Franco, Luis
    Amat-Santos, Ignacio J.
    Ruile, Philipp
    Estevez-Loureiro, Rodrigo
    Bunc, Matjaz
    Branca, Luca
    De Backer, Ole
    Tarantini, Giuseppe
    Mylotte, Darren
    Arzamendi, Dabit
    Pauly, Markus
    Bleiziffer, Sabine
    Renker, Matthias
    Al-Kassou, Baravan
    Mollmann, Helge
    Ludwig, Sebastian
    Zeus, Tobias
    Tamburino, Corrado
    Schmidt, Tobias
    Rueck, Andreas
    von Stein, Philipp
    Thiele, Holger
    Abdelhafez, Ahmed
    Adam, Matti
    Baldus, Stephan
    Rudolph, Tanja
    Mauri, Victor
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (22) : 2626 - 2635
  • [23] The relevance of prosthesis-patient mismatch after aortic valve replacement
    Pibarot, Philippe
    Dumesnil, Jean G.
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (12): : 764 - 765
  • [24] PROSTHESIS-PATIENT MISMATCH BETWEEN TRANSCATHETER HEART VALVES IN TRANSCATHETER AORTIC VALVE REPLACEMENT
    Sengupta, Aditya
    Zaid, Syed
    Storch, Jason
    Gupta, Eisha
    Hirji, Sameer
    Ahmad, Hasan
    Khan, Asaad
    Undemir, Cenap
    Ali, Omar
    Skiles, Jeffrey
    Goldberg, Joshua
    Lansman, Steven
    Kovacic, Jason
    Dangas, George D.
    Sharma, Samin K.
    Kini, Annapoorna Subhash
    Ramlawi, Basel
    Shah, Pinak
    Kaneko, Tsuyoshi
    Tang, Gilbert
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1421 - 1421
  • [25] Incidence, predictors, and outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement A meta-analysis
    He, Shixin
    Fang, Zhenfei
    MEDICINE, 2020, 99 (24) : E20717
  • [27] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation With the Medtronic CoreValve System in Patients With Aortic Stenosis
    Tzikas, Apostolos
    Piazza, Nicolo
    Geleijnse, Marcel L.
    Van Mieghem, Nicolas
    Nuis, Rutger-Jan
    Schultz, Carl
    van Geuns, Robert-Jan
    Galema, Tjebbe W.
    Kappetein, Arie-Pieter
    Serruys, Patrick W.
    de Jaegere, Peter P.
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (02): : 255 - 260
  • [28] Impact of Valve Size on Prosthesis-Patient Mismatch and Aortic Valve Gradient After Transcatheter versus Surgical Aortic Valve Replacement
    Aalaei-Andabili, Seyed Hossein
    Lee, Teng C.
    Waheed, Nida
    Bavry, Anthony A.
    Petersen, John W.
    Wayangankar, Siddharth
    Arnaoutakis, George J.
    Anderson, R. David
    Beaver, Thomas M.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2019, 14 (03) : 243 - 250
  • [29] Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement
    Freeman, Melanie
    Webb, John G.
    Willson, Alexander B.
    Wheeler, Miriam
    Blanke, Philipp
    Moss, Robert R.
    Thompson, Christopher R.
    Munt, Brad
    Norgaard, Bjarne L.
    Yang, Tae-Hyun
    Min, James K.
    Poulsen, Steen
    Hansson, Nicolaj C.
    Binder, Ronald K.
    Toggweiler, Stefan
    Hague, Cameron
    Wood, David A.
    Pibarot, Philippe
    Leipsic, Jonathon
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (04) : 248 - 255
  • [30] Incidence and clinical outcome of prosthesis-patient mismatch after transcatheter aortic valve implantation with the CoreValve prosthesis
    Munoz-Garcia, Antonio J.
    Munoz-Garcia, Manuel
    Carrasco-Chinchilla, Fernando
    Molina-Mora, Maria J.
    Rodriguez-Bailon, Isabel
    Dominguez-Franco, Antonio J.
    Jimenez-Navarro, Manuel F.
    Alonso-Briales, Juan H.
    Gomez-Doblas, Juan J.
    Hernandez-Garcia, Jose M.
    de Teresa-Galvan, Eduardo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (03) : 1074 - 1076