Low-dose single-energy material decomposition in radiography using a sparse-view computed tomography scan

被引:1
|
作者
Kim, G. [1 ]
Lim, Y. [1 ]
Park, J. [1 ]
Cho, H. [1 ]
Park, C. [1 ]
Kim, K. [1 ]
Kang, S. [1 ]
Lee, D. [1 ]
Park, S. [1 ]
Lim, H. [1 ]
Lee, H. [1 ]
Jeon, D. [1 ]
Kim, W. [1 ]
Seo, C. [1 ]
Lee, M. [2 ]
机构
[1] Yonsei Univ, Dept Radiat Convergence Engn, Wonju, South Korea
[2] Asan Med Ctr, Dept Radiat Oncol, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Computed tomography; dictionary-learning; dual-energy material decomposition; low-dose single-energy material decomposition; SPECTRAL CT; IMAGE; REPRESENTATIONS; APPARATUS;
D O I
10.1080/10739149.2018.1556685
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dual-energy material decomposition (DEMD) is a well-established theoretical x-ray technique that uses low- and high-kilovoltage radiographs to separate soft tissue and bone in radiography and computed tomography (CT). However, it requires double exposures that result in increased patient radiation doses, causes increases in the execution time, and generates errors due to misregistration attributed to the patient motion between two scans. In this study, we investigated a low-dose, single-energy material decomposition (LSEMD) method in radiography using a sparse-view CT scan where the attenuation length in the object was estimated from the CT image. We performed a systematic simulation and an experiment to demonstrate the feasibility of use of the LSEMD method in radiography. Only 60 projections, far fewer than those required by the Nyquist sampling theory, were acquired at an x-ray tube voltage of 80 kV(p), and were used to reconstruct a sparse-view CT image with a state-of-the-art dictionary-learning (DL) algorithm. We investigated the image performance of the LSEMD and compared the elicited results with those obtained with the use of DEMD (80 kV(p) and 120 kV(p) were used). Our results indicate that the DL algorithm produced high-quality sparse-view CT images. Accordingly, the LSEMD method yielded material decomposition results that were very similar to the results elicited by the conventional DEMD method in radiography.
引用
收藏
页码:325 / 340
页数:16
相关论文
共 50 条
  • [41] Dual Energy CT with One Full Scan and a Second Sparse-View Scan Using Structure Preserving Iterative Reconstruction (SPIR)
    Wang, T.
    Zhu, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3682 - 3682
  • [42] Improved detection of cholesterol gallstones using quasi-material decomposition images generated from single-energy computed tomography images via deep learning
    Nishijima, Kojiro
    Shiraishi, Junji
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (02) : 360 - 366
  • [43] Evaluation of chest radiography and low-dose computed tomography as valuable screening tools for thoracic diseases
    Kasuga, Ikuma
    Maezawa, Hiromi
    Gamo, Sanae
    Yokoe, Yoshimi
    Yanagihara, Yuri
    Sugiyama, Tomoko
    Tokura, Michiyo
    Okayama, Mayumi
    Ohtsubo, Osamu
    MEDICINE, 2022, 101 (29) : E29261
  • [44] Low-dose computed tomography (LDCT) as an alternative to conventional radiography (CR) for paranasal sinuses imaging
    Wallner, C
    Coppenrath, EM
    Staudenmaier, R
    Szeimies, U
    Becker-Gaab, C
    Hahn, K
    RADIOLOGY, 1999, 213P : 444 - 445
  • [45] Sex Differences in the Prediction of Future Lung Cancer Risk Based on a Single Low-Dose Chest Computed Tomography Scan
    Simon, J.
    Mikhael, P.
    Tahir, I.
    Graur, A.
    Fata, A.
    Shepard, J. -A.
    Jacobson, F.
    Barzilay, R.
    Sequist, L.
    Pace, L.
    Fintelmann, F. J.
    JOURNAL OF THORACIC ONCOLOGY, 2023, 18 (11) : S170 - S170
  • [46] Chronic Rhinosinusitis in Allergic Asthmatic Patients: Radiography Versus Low-Dose Computed Tomography Evaluation
    Stelmach, Rafael
    Dias Junior, Servulo Azevedo
    Figueiredo, Claudia Maria
    Uezumi, Kiyomi
    Genu, Ana Maria
    Carvalho-Pinto, Regina Maria
    Cukier, Alberto
    JOURNAL OF ASTHMA, 2010, 47 (06) : 599 - 603
  • [47] Advances in Imaging (Intraop Cone-Beam Computed Tomography, Synthetic Computed Tomography, Bone Scan, Low-Dose Protocols)
    Jankowski, Pawel P.
    Chan, Justin P.
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2024, 35 (02) : 161 - 172
  • [48] Single-Energy Material Decomposition Using X-Ray Path Length Estimation
    Kis, Benedek Janos
    Sarnyai, Zsolt
    Kakonyi, Robert
    Erdelyi, Miklos
    Szabo, Gabor
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (06) : 768 - 777
  • [49] Dental Panoramic Imaging Using CBCT Projection Data with Single-Energy Material Decomposition
    Yang, H.
    Lim, Y.
    Shim, J.
    Jeon, D.
    Cho, H.
    MEDICAL PHYSICS, 2024, 51 (09) : 6594 - 6595
  • [50] Using Low-Dose Computed Tomography for Early Detection of Lung Cancer
    Rulli, Kristi S.
    Matthews, Eric