Low-dose single-energy material decomposition in radiography using a sparse-view computed tomography scan

被引:1
|
作者
Kim, G. [1 ]
Lim, Y. [1 ]
Park, J. [1 ]
Cho, H. [1 ]
Park, C. [1 ]
Kim, K. [1 ]
Kang, S. [1 ]
Lee, D. [1 ]
Park, S. [1 ]
Lim, H. [1 ]
Lee, H. [1 ]
Jeon, D. [1 ]
Kim, W. [1 ]
Seo, C. [1 ]
Lee, M. [2 ]
机构
[1] Yonsei Univ, Dept Radiat Convergence Engn, Wonju, South Korea
[2] Asan Med Ctr, Dept Radiat Oncol, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Computed tomography; dictionary-learning; dual-energy material decomposition; low-dose single-energy material decomposition; SPECTRAL CT; IMAGE; REPRESENTATIONS; APPARATUS;
D O I
10.1080/10739149.2018.1556685
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dual-energy material decomposition (DEMD) is a well-established theoretical x-ray technique that uses low- and high-kilovoltage radiographs to separate soft tissue and bone in radiography and computed tomography (CT). However, it requires double exposures that result in increased patient radiation doses, causes increases in the execution time, and generates errors due to misregistration attributed to the patient motion between two scans. In this study, we investigated a low-dose, single-energy material decomposition (LSEMD) method in radiography using a sparse-view CT scan where the attenuation length in the object was estimated from the CT image. We performed a systematic simulation and an experiment to demonstrate the feasibility of use of the LSEMD method in radiography. Only 60 projections, far fewer than those required by the Nyquist sampling theory, were acquired at an x-ray tube voltage of 80 kV(p), and were used to reconstruct a sparse-view CT image with a state-of-the-art dictionary-learning (DL) algorithm. We investigated the image performance of the LSEMD and compared the elicited results with those obtained with the use of DEMD (80 kV(p) and 120 kV(p) were used). Our results indicate that the DL algorithm produced high-quality sparse-view CT images. Accordingly, the LSEMD method yielded material decomposition results that were very similar to the results elicited by the conventional DEMD method in radiography.
引用
收藏
页码:325 / 340
页数:16
相关论文
共 50 条
  • [31] BONE-MINERAL ANALYSIS USING SINGLE-ENERGY COMPUTED-TOMOGRAPHY
    ORPHANOUDAKIS, SC
    JENSEN, PS
    RAUSCHKOLB, EN
    LANG, R
    RASMUSSEN, H
    INVESTIGATIVE RADIOLOGY, 1979, 14 (02) : 122 - 130
  • [32] Sparse-view virtual monochromatic computed tomography reconstruction using a dictionary-learning-based algorithm
    Kim, G. A.
    Park, J. E.
    Park, C. K.
    Lee, D. Y.
    Park, S. Y.
    Kim, K. S.
    Kang, S. Y.
    Cho, H. S.
    Seo, C. W.
    Lim, H. W.
    Lee, H. W.
    Jeon, D. H.
    Kim, W. S.
    Lim, Y. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 954
  • [33] Future of Low-Dose Computed Tomography and Dual-Energy Computed Tomography in Axial Spondyloarthritis
    Diekhoff, Torsten
    Hermann, Kay Geert A.
    Lambert, Robert G.
    CURRENT RHEUMATOLOGY REPORTS, 2022, 24 (06) : 198 - 205
  • [34] Future of Low-Dose Computed Tomography and Dual-Energy Computed Tomography in Axial Spondyloarthritis
    Torsten Diekhoff
    Kay Geert A. Hermann
    Robert G. Lambert
    Current Rheumatology Reports, 2022, 24 : 198 - 205
  • [35] Low-dose computed tomography versus plain abdominal radiography in the investigation of an acute abdomen
    Nguyen, Long K.
    Wong, Daniel D.
    Fatovich, Daniel M.
    Yeung, Justin M.
    Persaud, Jennifer
    Wood, Christopher J.
    de Vos, David
    Mendelson, Richard M.
    ANZ JOURNAL OF SURGERY, 2012, 82 (1-2) : 36 - 41
  • [36] Optimization of low-dose scan parameters in dual-energy computed tomography for displaying the anterior cruciate ligament
    Bai, Rui
    Li, Xiangdong
    Li, Rurui
    He, Xiaohua
    Wen, Zhibo
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (07)
  • [37] Lung Cancer Screening Using Low-Dose Computed Tomography
    Hirsch, Brandon
    RADIOLOGIC TECHNOLOGY, 2022, 93 (03) : 303CT - 321CT
  • [38] Low-dose material-specific radiography using monoenergetic photons
    Harms, Joseph
    Maloney, Luke
    Erickson, Anna
    PLOS ONE, 2019, 14 (09):
  • [39] Low-dose Computed Tomography Image Denoising based on Joint Wavelet and Sparse representation
    Ghadrdan, Samira
    Alirezaie, Javad
    Dillenseger, Jean-Louis
    Babyn, Paul
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 3325 - 3328
  • [40] Dual energy CT with one full scan and a second sparse-view scan using structure preserving iterative reconstruction (SPIR)
    Wang, Tonghe
    Zhu, Lei
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (18): : 6684 - 6706