Low-dose single-energy material decomposition in radiography using a sparse-view computed tomography scan

被引:1
|
作者
Kim, G. [1 ]
Lim, Y. [1 ]
Park, J. [1 ]
Cho, H. [1 ]
Park, C. [1 ]
Kim, K. [1 ]
Kang, S. [1 ]
Lee, D. [1 ]
Park, S. [1 ]
Lim, H. [1 ]
Lee, H. [1 ]
Jeon, D. [1 ]
Kim, W. [1 ]
Seo, C. [1 ]
Lee, M. [2 ]
机构
[1] Yonsei Univ, Dept Radiat Convergence Engn, Wonju, South Korea
[2] Asan Med Ctr, Dept Radiat Oncol, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Computed tomography; dictionary-learning; dual-energy material decomposition; low-dose single-energy material decomposition; SPECTRAL CT; IMAGE; REPRESENTATIONS; APPARATUS;
D O I
10.1080/10739149.2018.1556685
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dual-energy material decomposition (DEMD) is a well-established theoretical x-ray technique that uses low- and high-kilovoltage radiographs to separate soft tissue and bone in radiography and computed tomography (CT). However, it requires double exposures that result in increased patient radiation doses, causes increases in the execution time, and generates errors due to misregistration attributed to the patient motion between two scans. In this study, we investigated a low-dose, single-energy material decomposition (LSEMD) method in radiography using a sparse-view CT scan where the attenuation length in the object was estimated from the CT image. We performed a systematic simulation and an experiment to demonstrate the feasibility of use of the LSEMD method in radiography. Only 60 projections, far fewer than those required by the Nyquist sampling theory, were acquired at an x-ray tube voltage of 80 kV(p), and were used to reconstruct a sparse-view CT image with a state-of-the-art dictionary-learning (DL) algorithm. We investigated the image performance of the LSEMD and compared the elicited results with those obtained with the use of DEMD (80 kV(p) and 120 kV(p) were used). Our results indicate that the DL algorithm produced high-quality sparse-view CT images. Accordingly, the LSEMD method yielded material decomposition results that were very similar to the results elicited by the conventional DEMD method in radiography.
引用
收藏
页码:325 / 340
页数:16
相关论文
共 50 条
  • [1] Feasibility Study of an Improved Single-Energy Material Decomposition Method for Computed Tomography
    Kim, Guna
    Park, Soyoung
    Lim, Ilhan
    Song, Kanghyon
    Kim, Jong-Guk
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2022, 69 (06) : 1366 - 1374
  • [2] Low-dose X-ray computed tomography image reconstruction with a combined low-mAs and sparse-view protocol
    Gao, Yang
    Bian, Zhaoying
    Huang, Jing
    Zhang, Yunwan
    Niu, Shanzhou
    Feng, Qianjin
    Chen, Wufan
    Liang, Zhengrong
    Ma, Jianhua
    OPTICS EXPRESS, 2014, 22 (12): : 15190 - 15210
  • [3] Low-Dose Sparse-View HAADF-STEM-EDX Tomography of Nanocrystals Using Unsupervised Deep Learning
    Cha, Eunju
    Chung, Hyungjin
    Jang, Jaeduck
    Lee, Junho
    Lee, Eunha
    Ye, Jong Chul
    ACS NANO, 2022, 16 (07) : 10314 - 10326
  • [4] Single-Energy Material Decomposition in Radiography Using a Three-Dimensional Laser Scanner
    Guna Kim
    Younghwan Lim
    Jeongeun Park
    Woosung Kim
    Dongyeon Lee
    Hyosung Cho
    Chulkyu Park
    Seokyoon Kang
    Kyuseok Kim
    Soyoung Park
    Hyunwoo Lim
    Hunwoo Lee
    Duhee Jeon
    Journal of the Korean Physical Society, 2019, 75 : 153 - 159
  • [5] Single-Energy Material Decomposition in Radiography Using a Three-Dimensional Laser Scanner
    Kim, Guna
    Lim, Younghwan
    Park, Jeongeun
    Kim, Woosung
    Lee, Dongyeon
    Cho, Hyosung
    Park, Chulkyu
    Kang, Seokyoon
    Kim, Kyuseok
    Park, Soyoung
    Lim, Hyunwoo
    Lee, Hunwoo
    Jeon, Duhee
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 75 (02) : 153 - 159
  • [6] Sparse-View Reconstruction from Restored Low-Dose CT Projections
    Liu, Wenlei
    Rong, Junyan
    Gao, Peng
    Liao, Qimei
    Jiao, Chun
    Lu, Hongbing
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [7] Sparse-view proton computed tomography using modulated proton beams
    Lee, Jiseoc
    Kim, Changhwan
    Min, Byungjun
    Kwak, Jungwon
    Park, Seyjoon
    Lee, Se Byeong
    Park, Sungyong
    Cho, Seungryong
    MEDICAL PHYSICS, 2015, 42 (02) : 1129 - 1137
  • [8] Impact of Low-Dose Computed Tomography on Computed Tomography Orders and Scan Length
    Simmons, Curtis
    Milburn, James
    OCHSNER JOURNAL, 2019, 19 (04): : 303 - 308
  • [9] Sparse-view neutron-photon computed tomography: Object reconstruction and material discrimination
    Yazdanpanah, Ali Pour
    Hartman, Jessica
    Regentova, Emma
    Barzilov, Alexander
    APPLIED RADIATION AND ISOTOPES, 2018, 132 : 122 - 128
  • [10] Sparsity-induced dynamic guided filtering approach for sparse-view data toward low-dose x-ray computed tomography
    Yu, Wei
    Wang, Chengxiang
    Nie, Xiaoying
    Zeng, Dehui
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (23):