Performance of A R22 split-air-conditioner when retrofitted with ozone friendly refrigerants (R410A and R417A)

被引:0
|
作者
Bolaji, Bukola Olalekan [1 ]
机构
[1] Fed Univ Agr Abeokuta, Dept Mech Engn, Abeokuta, Nigeria
关键词
retrofitting; split-air-conditioners; experimental; performance; R22; R410A; R417A;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
R22 that has been used predominantly in air conditioning and in medium and low-temperature applications contains ozone depleting chlorine atoms and hence will be phased out eventually. This paper presents the experimental performance study of a split-air-conditioner using ozone friendly alternative refrigerants. The existing split-air-conditioner originally designed for R22 as the working fluid was retrofitted with R410A and R417A respectively, and the performance of the system was evaluated and compared with its performance when R22 was used. Experimental results showed that with R417A, the system had 1.9% higher refrigeration capacity and 14.2% lower with R410A when compared to that of R22. The average discharge pressure of the compressor obtained with R417A and R410A were 3.8% lower and 10.3% higher, respectively, than with R22. The lowest compressor power consumption and pressure ratio were obtained with the R417A retrofitted system. The average coefficient of performance (COP) obtained using R417A is 2.9% higher, while that of R410A is 8.4% lower than that of R22. Generally, with R417A the system consistently had the best performance in comparison to both R22 and R410A, indicating that R417A would be a better choice for retrofitting existing split-air-conditioners originally designed to use R22 as working fluid.
引用
收藏
页码:16 / 22
页数:7
相关论文
共 50 条
  • [41] R22、R410A和R290在水平圆管内冷凝数值模拟
    尚少文
    荣来誉
    朱晨
    钱浩
    沈阳建筑大学学报(自然科学版), 2021, 37 (01) : 156 - 163
  • [42] CHARGE REDUCTION FOR A R22 SPLIT AIR CONDITIONER OPERATED WITH R290 UNDER DT AND ETB CONDITIONS
    Saravanan, A. Lalitha
    Lal, D. Mohan
    Duraisamy, A.
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 146 - 153
  • [43] A comparative performance study of a direct expansion geothermal evaporator using R410A and R407C as refrigerant alternatives to R22
    Fannou, Jean-Louis Comlan
    Rousseau, Clement
    Lamarche, Louis
    Kajl, Stanislaw
    APPLIED THERMAL ENGINEERING, 2015, 82 : 306 - 317
  • [44] A Comprehensive Energetic and Exergetic Analysis of an Ejector Expansion Refrigeration Cycle Using R22 and R410A
    Al-Chlaihawi, Kadhim K. Idan
    Al-Farhany, Khaled
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2021, 29 (02)
  • [45] 关于R410A和R22翅片管换热器回路数比的探讨
    申广玉
    流体机械, 2007, (06) : 83 - 85
  • [46] R410A替代R22空调蒸发器的换热性能
    段雪涛
    高凤玲
    邬志敏
    王芳
    河南科技大学学报(自然科学版), 2009, 30 (02) : 54 - 56+61+112
  • [47] R410A替代R22在空调器上应用试验研究
    曾伟强
    家电科技, 2007, (08) : 44 - 45
  • [48] 水平微圆管内R22和R410a凝结换热试验
    张会勇
    李俊明
    王补宣
    机械工程学报, 2008, (03) : 70 - 74
  • [49] Drop-In Tests and Simulation Results of R410A & Blends in an R32-Dedicated Mini-Split Air Conditioner
    Kataoka, Osami
    Ota, Fumio
    Nishikawa, Kazuyuki
    2016 ASHRAE ANNUAL CONFERENCE PAPERS, 2016,
  • [50] R417A和R22用于空气源热泵热水器的试验研究
    谭家碳
    黎昌尉
    仇富强
    唐亚军
    伍湘红
    制冷与空调, 2009, 9 (04) : 30 - 32