Performance of A R22 split-air-conditioner when retrofitted with ozone friendly refrigerants (R410A and R417A)

被引:0
|
作者
Bolaji, Bukola Olalekan [1 ]
机构
[1] Fed Univ Agr Abeokuta, Dept Mech Engn, Abeokuta, Nigeria
关键词
retrofitting; split-air-conditioners; experimental; performance; R22; R410A; R417A;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
R22 that has been used predominantly in air conditioning and in medium and low-temperature applications contains ozone depleting chlorine atoms and hence will be phased out eventually. This paper presents the experimental performance study of a split-air-conditioner using ozone friendly alternative refrigerants. The existing split-air-conditioner originally designed for R22 as the working fluid was retrofitted with R410A and R417A respectively, and the performance of the system was evaluated and compared with its performance when R22 was used. Experimental results showed that with R417A, the system had 1.9% higher refrigeration capacity and 14.2% lower with R410A when compared to that of R22. The average discharge pressure of the compressor obtained with R417A and R410A were 3.8% lower and 10.3% higher, respectively, than with R22. The lowest compressor power consumption and pressure ratio were obtained with the R417A retrofitted system. The average coefficient of performance (COP) obtained using R417A is 2.9% higher, while that of R410A is 8.4% lower than that of R22. Generally, with R417A the system consistently had the best performance in comparison to both R22 and R410A, indicating that R417A would be a better choice for retrofitting existing split-air-conditioners originally designed to use R22 as working fluid.
引用
收藏
页码:16 / 22
页数:7
相关论文
共 50 条
  • [21] A comparative study on the performance of a R22 window air conditioner retrofitted with R407C/R290/R600a refrigerant mixture
    Raj, M. H.
    Lal, D. M.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2008, 29 (04) : 207 - 217
  • [22] Condensation pressure drop of R22, R134a and R410A in a single circular microtube
    Son, Chang-Hyo
    Oh, Hoo-Kyu
    HEAT AND MASS TRANSFER, 2012, 48 (08) : 1437 - 1450
  • [23] Evaporating heat transfer of R22 and R410A in horizontal smooth and microtin tubes
    Kim, MH
    Shin, JS
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (06): : 940 - 948
  • [24] Condensation heat transfer of R22 and R410A in horizontal smooth and microfin tubes
    Kim, MH
    Shin, JS
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (06): : 949 - 957
  • [25] EXPERIMENTAL AND CFD INVESTIGATION OF R410A DISTRIBUTORS FOR AIR CONDITIONER
    Han, Qing
    Zhang, Chi
    Chen, Jiangping
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2014, 22 (02)
  • [26] R417A替代家用空调器用R22的实验研究
    张明方
    李鹏荣
    制冷与空调, 2006, (05) : 80 - 82
  • [27] R417A与R22流动沸腾换热性能的比较分析
    张小艳
    张进
    赵登育
    西安科技大学学报, 2012, 32 (01) : 86 - 90
  • [28] Condensation of R22 Retrofit Substitutes R417A, R422A, and R422D on Horizontal Smooth Tubes
    Uhia, Francisco J.
    Fernandez-Seara, Jose
    Alberto Dopazo, J.
    Diz, Ruben
    HEAT TRANSFER ENGINEERING, 2012, 33 (14) : 1188 - 1195
  • [29] R32、R22、R410A风冷空调机性能实验研究
    陈政文
    王娜娜
    胡文举
    倪龙
    江辉民
    低温建筑技术, 2012, 34 (11) : 120 - 122
  • [30] R22和R410A多联机配管长度理论分析
    申晓宇
    朱蒙佳
    张帆
    制冷与空调(四川), 2009, 23 (四川) : 114 - 118