Electrically heated cylindrical microelectrodes. Determination of lead on Pt by cyclic voltammetry and cathodic stripping analysis

被引:56
|
作者
Zerihun, T [1 ]
Grundler, P [1 ]
机构
[1] UNIV ROSTOCK,FACHBEREICH CHEM,D-18055 ROSTOCK,GERMANY
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1996年 / 415卷 / 1-2期
关键词
lead; platinum; microelectrodes; cyclic voltammetry; cathodic stripping;
D O I
10.1016/S0022-0728(96)04711-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The experiment involved cathodic stripping analysis of electrodeposited PbO2 in aqueous solutions of Pb2+ and HClO4 on a vertically arranged cylindrical Pt microelectrode (25 mu m diameter) at increased electrode temperature and free convection. The electrode was continuously heated in-situ using a 100 kHz alternating current during d.c. polarization. The stripping signals at the heated electrode were much better than those obtained at room temperature. Cyclic voltammetry and potentiostatic (anodic) deposition followed by a negative linear potential sweep were used for the deposition and stripping of PbO2.
引用
收藏
页码:85 / 88
页数:4
相关论文
共 41 条
  • [21] Determination of trace tellurium in steel and lead by cathodic stripping voltammetry based on non-electrolytic preconcentration
    Ishiyama, T
    Tanaka, T
    JOURNAL OF THE JAPAN INSTITUTE OF METALS, 1999, 63 (04) : 515 - 519
  • [22] Simultaneous determination of copper, lead and cadmium by cathodic adsorptive stripping voltammetry using artificial neural network
    Ensafi, AA
    Khayamian, T
    Benvidi, A
    Mirmomtaz, E
    ANALYTICA CHIMICA ACTA, 2006, 561 (1-2) : 225 - 232
  • [23] Determination of lead and copper in wine by anodic stripping voltammetry with mercury microelectrodes: Assessment of the influence of sample pretreatment procedures
    Baldo, MA
    Bragato, C
    Daniele, S
    ANALYST, 1997, 122 (01) : 1 - 5
  • [24] Trace analysis of lead by anodic stripping voltammetry with collection at interdigitated microelectrodes in small-volume samples
    M. Rievaj
    Z. Dovalovská
    D. Bustin
    Chemical Papers, 2006, 60 : 111 - 115
  • [25] Trace analysis of lead by anodic stripping voltammetry with collection at interdigitated microelectrodes in small-volume samples
    Rievaj, M.
    Dovalovska, Z.
    Bustin, D.
    CHEMICAL PAPERS, 2006, 60 (02) : 111 - 115
  • [26] Application of Calcon as Complexing Agent for the Simultaneous Determination of Lead and Cadmium in Sea Water with Adsorptive Cathodic Stripping Voltammetry
    Deswati
    Pardi, Hilfi
    Suyani, Hamzar
    Yusuf, Yulizar
    Edelwis, Tri Widya
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (05): : 541 - 553
  • [27] Enhanced Cathodic Preconcentration of As(0) at Au and Pt Electrodes for Anodic Stripping Voltammetry Analysis of As(III) and As(V)
    Bu, Lijuan
    Gu, Tiean
    Ma, Yixuan
    Chen, Chao
    Tan, Yueming
    Xie, Qingji
    Yao, Shouzhuo
    JOURNAL OF PHYSICAL CHEMISTRY C, 2015, 119 (21): : 11400 - 11409
  • [28] SQUARE-WAVE ANODIC-STRIPPING VOLTAMMETRY OF LEAD AND CADMIUM AT CYLINDRICAL GRAPHITE FIBER MICROELECTRODES WITH INSITU PLATED MERCURY FILMS
    WOJCIECHOWSKI, M
    BALCERZAK, J
    ANALYTICA CHIMICA ACTA, 1991, 249 (02) : 433 - 445
  • [29] Electrochemical Behavior and Adsorptive Stripping Analysis of Flavin Adenine Dinucleotide at Electrically Heated Graphite Cylindrical Electrodes
    Wu Shao-Hua
    Nie Fa-Hui
    Lin Zhi-Bin
    Dai Hui-Ming
    Zhang De-Feng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (09) : 1228 - 1232
  • [30] Sono-cathodic stripping voltammetry of lead at a polished boron-doped diamond electrode:: Application to the determination of lead in river sediment
    Saterlay, AJ
    Agra-Gutiérrez, C
    Taylor, MP
    Marken, F
    Compton, RG
    ELECTROANALYSIS, 1999, 11 (15) : 1083 - 1088