Trace analysis of lead by anodic stripping voltammetry with collection at interdigitated microelectrodes in small-volume samples

被引:2
|
作者
Rievaj, M. [1 ]
Dovalovska, Z. [1 ]
Bustin, D. [1 ]
机构
[1] Slovak Univ Technol Bratislava, Fac Chem & Food Technol, Dept Analyt Chem, SK-81237 Bratislava, Slovakia
关键词
D O I
10.2478/s11696-006-0020-1
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A simple and sensitive electroanalytical method was developed for microvolume trace elements determination. Commercially available interdigitated microelectrodes (IDA) from ALS Japan Inc. based on a thin carbon film technology were used. Anodic stripping voltammetry with collection at IDA was applied. Carbon IDA microbands were coated with a pre-deposited mercury film for better performance. The method with this sensor enables analysis of some heavy metals in total sample volumes as small as 0.05 cm(3). The method was applied to Pb in blood samples determination by a standard addition method.
引用
收藏
页码:111 / 115
页数:5
相关论文
共 50 条
  • [1] Trace analysis of lead by anodic stripping voltammetry with collection at interdigitated microelectrodes in small-volume samples
    M. Rievaj
    Z. Dovalovská
    D. Bustin
    Chemical Papers, 2006, 60 : 111 - 115
  • [2] TRACE ANALYSIS OF NICKEL MICROSAMPLES FOR LEAD AND COPPER BY ANODIC-STRIPPING VOLTAMMETRY
    MIWA, T
    RUBI, S
    MIZUIKE, A
    BUNSEKI KAGAKU, 1983, 32 (02) : E49 - E52
  • [3] DETERMINATION OF TRACE METALS IN MARINE SAMPLES BY ANODIC STRIPPING VOLTAMMETRY
    FLORENCE, TM
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1972, 35 (NMAR): : 237 - &
  • [4] Trace Determination of Lead in Environmental and Biological Samples by Anodic Stripping Voltammetry on Carbon Paste Electrode
    Rievaj, Miroslav
    Tomcik, Peter
    Cernanska, Monika
    Janosikova, Zuzana
    Bustin, Dusan
    CHEMIA ANALITYCZNA, 2008, 53 (05): : 717 - 723
  • [5] Determination of trace lead by square-wave anodic stripping voltammetry
    Wang, Mingliang
    Li, Minjing
    Yejin Fenxi/Metallurgical Analysis, 2000, 20 (01): : 42 - 44
  • [6] DETERMINATION OF TRACE AMOUNTS OF LEAD IN STEEL BY ANODIC-STRIPPING VOLTAMMETRY
    METTERS, B
    COOKSEY, BG
    ANALYST, 1974, 99 (1181) : 457 - 468
  • [7] EFFECTS OF BACKGROUND ELECTROLYTE AND OXYGEN ON TRACE ANALYSIS FOR LEAD AND CADMIUM BY ANODIC-STRIPPING VOLTAMMETRY
    FERNANDO, AR
    PLAMBECK, JA
    ANALYTICAL CHEMISTRY, 1989, 61 (23) : 2609 - 2611
  • [8] DIGESTION OF SOIL SAMPLES FOR THE DETERMINATION OF TRACE AMOUNTS OF LEAD BY DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY
    FERNANDO, AR
    PLAMBECK, JA
    ANALYST, 1992, 117 (01) : 39 - 42
  • [9] Anodic stripping voltammetry of trace metals by batch injection analysis
    Brett, CMA
    Brett, AMO
    Tugulea, L
    ANALYTICA CHIMICA ACTA, 1996, 322 (03) : 151 - 157
  • [10] SELECTED TRACE METAL DETERMINATION OF SPOT TAPE SAMPLES BY ANODIC STRIPPING VOLTAMMETRY
    MACLEOD, KE
    LEE, RE
    ANALYTICAL CHEMISTRY, 1973, 45 (14) : 2380 - 2383