Numerical procedure for predicting annual energy consumption of the under-floor air distribution system

被引:49
|
作者
Xu, HT [1 ]
Niu, JL [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
UFAD; mixing; CFD; ACCURACY; simulation;
D O I
10.1016/j.enbuild.2005.10.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As compared with the mixing system, indoor air temperature stratification in the under-floor air distribution (UFAD) system offers an opportunity for cooling load reduction in the occupied zone. This stratification is a major feature that offers the energy saving potential, but it has not been thoroughly taken into account in most energy simulation programs. In this article, a numerical procedure, based on coupling two types of modeling, i.e., CFD (computational fluid dynamic) simulation and dynamic cooling load simulation, is proposed to predict annual energy consumption. The dimensionless temperature coefficient is first defined in the UFAD system and obtained from CFD simulation, based on the boundary conditions from a cooling load program ACCURACY. According to this coefficient, temperature stratification input to ACCURACY is then revised to calculate the updated supply and exhaust air temperatures for final annual energy prediction. To demonstrate the method, a small office room is investigated using Hong Kong weather data. With the constant air volume (CAV) supply in the UFAD system, it is found that the dimensionless temperature coefficient is almost a constant, when the locations of heat sources are fixed. As compared with the mixing system, the UFAD system derives its energy saving potential from the following three factors: an extended free cooling time, a reduced ventilation load, and increased coefficients of performance (COP) for chillers. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:641 / 647
页数:7
相关论文
共 50 条
  • [21] Prediction of thermal comfort, IAQ, and energy consumption in a dense occupancy environment with the under floor air distribution system
    Fathollahzadeh, Mohammad Hassan
    Heidarinejad, Ghassem
    Pasdarshahri, Hadi
    BUILDING AND ENVIRONMENT, 2015, 90 : 96 - 104
  • [22] Indoor air quality and thermal comfort studies of an under-floor air-conditioning system in the tropics
    Sekhar, SC
    Ching, CS
    ENERGY AND BUILDINGS, 2002, 34 (05) : 431 - 444
  • [23] Thermal comfort and indoor air quality in rooms with integrated personalized ventilation and under-floor air distribution systems
    Li, Ruixin
    Sekhar, S. C.
    Melikov, A. K.
    HVAC&R RESEARCH, 2011, 17 (05): : 829 - 846
  • [24] Uniformity of Supply Air in the Plenum for Under-Floor Air Distribution Ventilation in a Circular Conference Room: A CFD Study
    Fan, Xiaolei
    Yu, Tao
    Liu, Peng
    Li, Xiangdong
    ENERGIES, 2022, 15 (17)
  • [25] Effects of return air vent height on energy consumption, thermal comfort conditions and indoor air quality in an under floor air distribution system
    Heidarinejad, Ghassem
    Fathollahzadeh, Mohammad Hassan
    Pasdarshahri, Hadi
    ENERGY AND BUILDINGS, 2015, 97 : 155 - 161
  • [26] A model for an under floor air distribution system
    Lin, YJP
    Linden, PF
    ENERGY AND BUILDINGS, 2005, 37 (04) : 399 - 409
  • [27] Modelling and economic optimisation of under-floor heating system
    Sanaye, Sepehr
    Mahmoudimehr, Javad
    Aynechi, Mohsen
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2012, 33 (02): : 191 - 202
  • [28] Comparison of Airflow and Contaminant Distributions in Rooms with Traditional Displacement Ventilation and Under-Floor Air Distribution Systems
    Lee, Kisup
    Zhang, Tengfei
    Jiang, Zheng
    Chen, Qingyan
    ASHRAE TRANSACTIONS 2009, VOL 115, PT 2, 2009, 115 : 306 - +
  • [29] Comparison of indoor air temperatures of different under-floor heating pipe layouts
    Gao, Ran
    Li, Angui
    Zhang, Ou
    Zhang, Hua
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (02) : 1295 - 1304
  • [30] Simulation of thermal performance of under-floor electric heating system with latent heat thermal energy storage plate
    Lin, Kunping
    Zhang, Yinping
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2003, 24 (05): : 633 - 637