Evaluation of 3D-2D Registration Methods for Registration of 3D-DSA and 2D-DSA Cerebral Images

被引:1
|
作者
Mitrovic, Uros [1 ]
Spiclin, Ziga [1 ]
Likar, Bostjan [1 ]
Pernus, Franjo [1 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, Lab Imaging Technol, Ljubljana 1000, Slovenia
来源
关键词
3D-2D image registration; cerebral angiograms; DSA; performance evaluation; gold standard; STANDARDIZED EVALUATION METHODOLOGY; X-RAY IMAGES; 3D/2D REGISTRATION; 2-D-3-D REGISTRATION; 3-D/2-D REGISTRATION; 3D; ANGIOGRAPHY; CT; INFORMATION; FIDUCIALS;
D O I
10.1117/12.2007009
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Recent C-arm systems used for endovascular image-guided interventions enable the acquisition of three-dimensional (3D) and dynamic two-dimensional (2D+t) images in the same interventional suite. The 3D images are used to observe the vascular morphology while the 2D+t images show the current state of the intervention. By spatial alignment of 3D and 2D+t images one can facilitate the endovascular interventions, e.g. by displaying the intra-interventional tools and contrast-agent flow in the augmented 3D+t images. To achieve the spatial alignment several 3D-2D registration methods were proposed that are concerned with finding the rigid-body parameters of the 3D image. Meanwhile, the pose of the C-arm system is usually obtained through a dedicated C-arm calibration. In practice, the calibrated C-arm pose parameters are typically valid only if the imaged object is positioned in the C-arm's isocenter. To compensate this, the 3D-2D registration should search simultaneously for the rigid-body as well as the C-arm pose parameters. For verification, we tested three 3D-2D registration methods on real, clinical 3D and 2D+t angiographic images of twenty patients, ten of which were imaged with attached fiducial markers to obtain a "gold standard" registration. The results indicate that, compared to searching solely the rigid-body parameters, by searching simultaneously for rigid-body and the C-arm pose parameters significantly improves the accuracy and success rate of 3D-2D registration methods. Among the three tested methods the intensity-based method using mutual information was the most robust, as it successfully registered all clinical datasets, and highly accurate, as the maximal fiducial registration error was less or equal than 0 34 mm.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] 3D-DSA与2D-DSA引导支架取栓术联合静脉溶栓对老年急性脑梗死的临床疗效
    周高领
    何庆
    刘鹏飞
    菏泽医学专科学校学报, 2025, 37 (01) : 5 - 8
  • [42] Standardized evaluation methodology for 2-D-3-D registration
    van de Kraats, EB
    Penney, GP
    Tomazevic, D
    van Walsum, T
    Niessen, WJ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (09) : 1177 - 1189
  • [43] Neural patient-specific 3D-2D registration in laparoscopic liver resection
    Mhiri, Islem
    Pizarro, Daniel
    Bartoli, Adrien
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2025, 20 (01) : 57 - 64
  • [44] Automated Multimodal Computer Aided Detection Based on a 3D-2D Image Registration
    Hopp, T.
    Neupane, B.
    Ruiter, N. V.
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 400 - 407
  • [45] 3D-2D Medical Image Registration Technology and Its Application Development: a Survey
    Xiao, Handan
    PROCEEDINGS OF 2023 4TH INTERNATIONAL SYMPOSIUM ON ARTIFICIAL INTELLIGENCE FOR MEDICINE SCIENCE, ISAIMS 2023, 2023, : 95 - 100
  • [46] Using Multiple Images and Contours for Deformable 3D-2D Registration of a Preoperative CT in Laparoscopic Liver Surgery
    Espinel, Yamid
    Calvet, Lilian
    Botros, Karim
    Buc, Emmanuel
    Tilmant, Christophe
    Bartoli, Adrien
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT IV, 2021, 12904 : 657 - 666
  • [47] 2D/3D registration of neonatal brain images
    Vansteenkiste, Ewout
    Vandemeulebroucke, Jef
    Philips, Wilfried
    BIOMEDICAL IMAGE REGISTRATION, PROCEEDINGS, 2006, 4057 : 272 - 279
  • [48] Using multiple images and contours for deformable 3D-2D registration of a preoperative CT in laparoscopic liver surgery
    Espinel, Yamid
    Calvet, Lilian
    Botros, Karim
    Buc, Emmanuel
    Tilmant, Christophe
    Bartoli, Adrien
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (12) : 2211 - 2219
  • [49] Advancements in 2D/3D Image Registration Methods
    Hjouj, Fawaz
    Jouini, Mohamed Soufiane
    Al-Khaleel, Mohammad
    IEEE ACCESS, 2023, 11 : 34698 - 34708
  • [50] Clinical benefits and pitfalls of 3D-DSA in neurointerventional procedure for ruptured cerebral aneurysm
    Abe, T
    Tanigawa, H
    Tanaka, N
    Hirohata, M
    Uchiyama, Y
    Hayabuchi, N
    RADIOLOGY, 2000, 217 : 179 - 179