Evaluation of 3D-2D Registration Methods for Registration of 3D-DSA and 2D-DSA Cerebral Images

被引:1
|
作者
Mitrovic, Uros [1 ]
Spiclin, Ziga [1 ]
Likar, Bostjan [1 ]
Pernus, Franjo [1 ]
机构
[1] Univ Ljubljana, Fac Elect Engn, Lab Imaging Technol, Ljubljana 1000, Slovenia
来源
关键词
3D-2D image registration; cerebral angiograms; DSA; performance evaluation; gold standard; STANDARDIZED EVALUATION METHODOLOGY; X-RAY IMAGES; 3D/2D REGISTRATION; 2-D-3-D REGISTRATION; 3-D/2-D REGISTRATION; 3D; ANGIOGRAPHY; CT; INFORMATION; FIDUCIALS;
D O I
10.1117/12.2007009
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Recent C-arm systems used for endovascular image-guided interventions enable the acquisition of three-dimensional (3D) and dynamic two-dimensional (2D+t) images in the same interventional suite. The 3D images are used to observe the vascular morphology while the 2D+t images show the current state of the intervention. By spatial alignment of 3D and 2D+t images one can facilitate the endovascular interventions, e.g. by displaying the intra-interventional tools and contrast-agent flow in the augmented 3D+t images. To achieve the spatial alignment several 3D-2D registration methods were proposed that are concerned with finding the rigid-body parameters of the 3D image. Meanwhile, the pose of the C-arm system is usually obtained through a dedicated C-arm calibration. In practice, the calibrated C-arm pose parameters are typically valid only if the imaged object is positioned in the C-arm's isocenter. To compensate this, the 3D-2D registration should search simultaneously for the rigid-body as well as the C-arm pose parameters. For verification, we tested three 3D-2D registration methods on real, clinical 3D and 2D+t angiographic images of twenty patients, ten of which were imaged with attached fiducial markers to obtain a "gold standard" registration. The results indicate that, compared to searching solely the rigid-body parameters, by searching simultaneously for rigid-body and the C-arm pose parameters significantly improves the accuracy and success rate of 3D-2D registration methods. Among the three tested methods the intensity-based method using mutual information was the most robust, as it successfully registered all clinical datasets, and highly accurate, as the maximal fiducial registration error was less or equal than 0 34 mm.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Registration, matching, and data fusion in 2D/3D medical imaging: Application to DSA and MRA
    Vermandel, M
    Betrouni, N
    Palos, G
    Gauvrit, JY
    Vasseur, C
    Rousseau, J
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 1, 2003, 2878 : 778 - 785
  • [32] Combining Visual Cues with Interactions for 3D-2D Registration in Liver Laparoscopy
    Espinel, Yamid
    Ozgur, Erol
    Calvet, Lilian
    Le Roy, Bertrand
    Buc, Emmanuel
    Bartoli, Adrien
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (06) : 1712 - 1727
  • [33] 3D-2D projective registration of free-form curves and surfaces
    Feldmar, J
    Ayache, N
    Betting, F
    COMPUTER VISION AND IMAGE UNDERSTANDING, 1997, 65 (03) : 403 - 424
  • [34] Monoplane 3D-2D registration of cerebral angiograms based on multi-objective stratified optimization
    Aksoy, T.
    Spiclin, Z.
    Pernus, F.
    Unal, G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (24): : 9377 - 9394
  • [35] A quick 3D-2D registration method for a wide-range of applications
    Kita, Y
    Wilson, DL
    Noble, JA
    Kita, N
    15TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOL 1, PROCEEDINGS: COMPUTER VISION AND IMAGE ANALYSIS, 2000, : 981 - 986
  • [36] Quantitative and Qualitative Comparison of 4D-DSA with 3D-DSA Using Computational Fluid Dynamics Simulations in Cerebral Aneurysms
    Lang, S.
    Hacker, P.
    Birkhold, A., I
    Schmidt, M.
    Endres, J.
    Strother, C.
    Doerfler, A.
    Luecking, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (09) : 1505 - 1510
  • [37] Automatic Artery/Vein Classification in 2D-DSA Images of Stroke Patients
    Van Asperen, Vivian
    Von den Berg, Josefien
    Lycklama, Fleur
    Marting, Victoria
    Cornelissen, Sandra
    Van Zwam, Wim
    Hofmeijer, Jeanette
    Von Der Lugt, Aad
    Van Walsum, Theo
    Von Der Sluijs, Matthijs
    Su, Ruisheng
    MEDICAL IMAGING 2022: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2022, 12034
  • [38] Benefits of 3D Rotational DSA Compared with 2D DSA in the Evaluation of Intracranial Aneurysm
    Wong, Siong Chuong
    Nawawi, Ouzreiah
    Ramli, Norlisah
    Abd Kadir, Khairul Azmi
    ACADEMIC RADIOLOGY, 2012, 19 (06) : 701 - 707
  • [39] FMB: Dual-view fusion and registration of 2D DSA images and 3D MRA images for neurointerventional-based procedures
    Zhang, Chenyu
    Liu, Jiaxin
    Bian, Lisong
    Xiang, Sishi
    Liu, Jun
    Guan, Wenxue
    COMPUTERS IN BIOLOGY AND MEDICINE, 2024, 171
  • [40] FMB: Dual-view fusion and registration of 2D DSA images and 3D MRA images for neurointerventional-based procedures
    Zhang, Chenyu
    Liu, Jiaxin
    Bian, Lisong
    Xiang, Sishi
    Liu, Jun
    Guan, Wenxue
    Computers in Biology and Medicine, 2024, 171