Construct validity of individual and summary performance metrics associated with a computer-based laparoscopic simulator

被引:15
|
作者
Rivard, Justin D. [1 ]
Vergis, Ashley S. [1 ]
Unger, Bertram J. [2 ]
Hardy, Krista M. [1 ]
Andrew, Chris G. [1 ]
Gillman, Lawrence M. [1 ]
Park, Jason [1 ]
机构
[1] Univ Manitoba, Dept Surg, St Boniface Gen Hosp, Winnipeg, MB R2H 2A6, Canada
[2] Univ Manitoba, Dept Med Educ, Winnipeg, MB R2H 2A6, Canada
关键词
Evaluation; Education; Laparoscopic surgery; Simulation; Virtual reality; Validation; VIRTUAL-REALITY SIMULATION; BENCH MODEL FIDELITY; OPERATING-ROOM; SKILLS; PROFICIENCY; IMPACT; ACQUISITION; TRAINER; FUNDAMENTALS; LAPSIM;
D O I
10.1007/s00464-013-3414-5
中图分类号
R61 [外科手术学];
学科分类号
摘要
Computer-based surgical simulators capture a multitude of metrics based on different aspects of performance, such as speed, accuracy, and movement efficiency. However, without rigorous assessment, it may be unclear whether all, some, or none of these metrics actually reflect technical skill, which can compromise educational efforts on these simulators. We assessed the construct validity of individual performance metrics on the LapVR simulator (Immersion Medical, San Jose, CA, USA) and used these data to create task-specific summary metrics. Medical students with no prior laparoscopic experience (novices, N = 12), junior surgical residents with some laparoscopic experience (intermediates, N = 12), and experienced surgeons (experts, N = 11) all completed three repetitions of four LapVR simulator tasks. The tasks included three basic skills (peg transfer, cutting, clipping) and one procedural skill (adhesiolysis). We selected 36 individual metrics on the four tasks that assessed six different aspects of performance, including speed, motion path length, respect for tissue, accuracy, task-specific errors, and successful task completion. Four of seven individual metrics assessed for peg transfer, six of ten metrics for cutting, four of nine metrics for clipping, and three of ten metrics for adhesiolysis discriminated between experience levels. Time and motion path length were significant on all four tasks. We used the validated individual metrics to create summary equations for each task, which successfully distinguished between the different experience levels. Educators should maintain some skepticism when reviewing the plethora of metrics captured by computer-based simulators, as some but not all are valid. We showed the construct validity of a limited number of individual metrics and developed summary metrics for the LapVR. The summary metrics provide a succinct way of assessing skill with a single metric for each task, but require further validation.
引用
收藏
页码:1921 / 1928
页数:8
相关论文
共 50 条
  • [41] Construct, content and face validity of the eoSim laparoscopic simulator on advanced suturing tasks
    Erik Leijte
    Elke Arts
    Bart Witteman
    Jack Jakimowicz
    Ivo De Blaauw
    Sanne Botden
    Surgical Endoscopy, 2019, 33 : 3635 - 3643
  • [42] Establishing construct validity for basic laparoscopic skill sets on an augmented reality simulator
    Nugent, E.
    Hseino, H.
    Shirilla, N.
    Traynor, O.
    Neary, P.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2011, 180 : S275 - S275
  • [43] Construct, content and face validity of the eoSim laparoscopic simulator on advanced suturing tasks
    Leijte, Erik
    Arts, Elke
    Witteman, Bart
    Jakimowicz, Jack
    De Blaauw, Ivo
    Botden, Sanne
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2019, 33 (11): : 3635 - 3643
  • [44] Challenges in metrics and measurement for computer-based systems
    Welch, LR
    Farr, W
    Uehara, M
    COMPUTER, 1997, 30 (01) : 88 - 89
  • [45] VIRTUAL REALITY SIMULATION FOR LAPAROSCOPIC COLECTOMY: CAN METRICS HAVE CONSTRUCT VALIDITY?
    Shanmugan, S.
    Leblanc, F.
    Senagore, A.
    Ellis, C.
    Nobel, T.
    Khan, S.
    Delaney, C.
    Champagne, B.
    DISEASES OF THE COLON & RECTUM, 2013, 56 (04) : E72 - E73
  • [46] COMPUTER-BASED JOURNAL DISTRIBUTION FOR INDIVIDUAL
    CABE, PA
    BROWN, WS
    PIERCE, JR
    TRAUB, JF
    SCIENCE, 1968, 160 (3824) : 209 - &
  • [47] A multicenter study to provide evidence of construct validity in a computer-based outcome measure of neurology clinical skills
    Obeso, VT
    Gordon, DL
    Issenberg, SB
    Baker, JW
    Clark, RG
    Reynolds, PS
    Lewis, SL
    Khan, J
    Petrusa, ER
    ACADEMIC MEDICINE, 2005, 80 (10) : S71 - S74
  • [48] Construct and face validity of the educational computer-based environment (ECE) assessment scenarios for basic endoneurosurgery skills
    Cagiltay, Nergiz Ercil
    Ozcelik, Erol
    Sengul, Gokhan
    Berker, Mustafa
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2017, 31 (11): : 4485 - 4495
  • [49] Construct and face validity of the educational computer-based environment (ECE) assessment scenarios for basic endoneurosurgery skills
    Nergiz Ercil Cagiltay
    Erol Ozcelik
    Gokhan Sengul
    Mustafa Berker
    Surgical Endoscopy, 2017, 31 : 4485 - 4495
  • [50] Validity and utility of computer-based test interpretation
    Butcher, JN
    Perry, JN
    Atlis, MM
    PSYCHOLOGICAL ASSESSMENT, 2000, 12 (01) : 6 - 18