Physiological noise reduction using volumetric functional magnetic resonance inverse imaging

被引:27
|
作者
Lin, Fa-Hsuan [2 ,3 ]
Nummenmaa, Aapo [3 ,4 ]
Witzel, Thomas [5 ]
Polimeni, Jonathan R. [3 ]
Zeffiro, Thomas A. [6 ]
Wang, Fu-Nien [1 ]
Belliveau, John W. [3 ]
机构
[1] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu, Taiwan
[2] Natl Taiwan Univ, Inst Biomed Engn, Taipei 10764, Taiwan
[3] MGH HST Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA USA
[4] Aalto Univ, Sch Sci & Technol, Dept Biomed Engn & Computat Sci, Espoo, Finland
[5] MIT, Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02139 USA
[6] Massachusetts Gen Hosp, Neural Syst Grp, Charlestown, MA USA
基金
芬兰科学院; 美国国家卫生研究院;
关键词
event-related; inverse imaging; Inl; visual; MRI; fMRI; neuroimaging; inverse solution; SURFACE-BASED ANALYSIS; ECHO-PLANAR; BRAIN MOTION; FMRI; FLUCTUATIONS; REGISTRATION; ACQUISITION; SUPPRESSION; EIGENMODES; PARAMETERS;
D O I
10.1002/hbm.21403
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Physiological noise arising from a variety of sources can significantly degrade the detection of task-related activity in BOLD-contrast fMRI experiments. If whole head spatial coverage is desired, effective suppression of oscillatory physiological noise from cardiac and respiratory fluctuations is quite difficult without external monitoring, since traditional EPI acquisition methods cannot sample the signal rapidly enough to satisfy the Nyquist sampling theorem, leading to temporal aliasing of noise. Using a combination of high speed magnetic resonance inverse imaging (InI) and digital filtering, we demonstrate that it is possible to suppress cardiac and respiratory noise without auxiliary monitoring, while achieving whole head spatial coverage and reasonable spatial resolution. Our systematic study of the effects of different moving average (MA) digital filters demonstrates that a MA filter with a 2 s window can effectively reduce the variance in the hemodynamic baseline signal, thereby achieving 57%58% improvements in peak z-statistic values compared to unfiltered InI or spatially smoothed EPI data (FWHM = 8.6 mm). In conclusion, the high temporal sampling rates achievable with InI permit significant reductions in physiological noise using standard temporal filtering techniques that result in significant improvements in hemodynamic response estimation. Hum Brain Mapp 33:2815-2830, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:2815 / 2830
页数:16
相关论文
共 50 条
  • [21] Motion correction and volumetric reconstruction for fetal functional magnetic resonance imaging data
    Sobotka, Daniel
    Ebner, Michael
    Schwartz, Ernst
    Nenning, Karl-Heinz
    Taymourtash, Athena
    Vercauteren, Tom
    Ourselin, Sebastien
    Kasprian, Gregor
    Prayer, Daniela
    Langs, Georg
    Licandro, Roxane
    NEUROIMAGE, 2022, 255
  • [22] Volumetric Fetal Flow Imaging With Magnetic Resonance Imaging
    Goolaub, Datta Singh
    Xu, Jiawei
    Schrauben, Eric M.
    Marini, Davide
    Kingdom, John C.
    Sled, John G.
    Seed, Mike
    Macgowan, Christopher K.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (10) : 2941 - 2952
  • [23] Reduction of Noise Correlation in Magnetic Resonance Imaging Coil Arrays with Metamaterials
    Freire, M. J.
    Algarin, J. M.
    Marques, R.
    2013 7TH INTERNATIONAL CONGRESS ON ADVANCED ELECTROMAGNETIC MATERIALS IN MICROWAVES AND OPTICS (METAMATERIALS 2013), 2013, : 529 - 531
  • [24] Sexual Dimorphism in Laryngeal Volumetric Measurements Using Magnetic Resonance Imaging
    Hamdan, Abdul-Latif
    Khalifee, Elie
    Ziade, Georges
    Semaan, Sahar
    ENT-EAR NOSE & THROAT JOURNAL, 2020, 99 (02) : 132 - 136
  • [25] Parallel Imaging-Based Reduction of Acoustic Noise for Clinical Magnetic Resonance Imaging
    Pierre, Eric Y.
    Grodzki, David
    Aandal, Gunhild
    Heismann, Bjoern
    Badve, Chaitra
    Gulani, Vikas
    Sunshine, Jeffrey L.
    Schluchter, Mark
    Liu, Kecheng
    Griswold, Mark A.
    INVESTIGATIVE RADIOLOGY, 2014, 49 (09) : 620 - 626
  • [26] Magnetic resonance imaging in the evaluation of temperature-controlled radiofrequency volumetric tissue reduction
    Stuck, BA
    Köpke, J
    Maurer, JT
    Verse, T
    Eckert, A
    Düber, C
    Hörmann, K
    HNO, 2003, 51 (09) : 717 - 720
  • [27] Volumetric Magnetic Resonance Imaging of the Musculoskeletal System
    Rosas, Humberto
    Kijowski, Richard
    SEMINARS IN ROENTGENOLOGY, 2013, 48 (02) : 140 - 147
  • [28] A volumetric magnetic resonance imaging study in migraine
    Laila Elmously Naguib
    Ghada Saed Abdel Azim
    Mohammed Abdelrazek Abdellatif
    The Egyptian Journal of Neurology, Psychiatry and Neurosurgery, 57
  • [29] A volumetric magnetic resonance imaging study in migraine
    Naguib, Laila Elmously
    Azim, Ghada Saed Abdel
    Abdellatif, Mohammed Abdelrazek
    EGYPTIAN JOURNAL OF NEUROLOGY PSYCHIATRY AND NEUROSURGERY, 2021, 57 (01):
  • [30] Linear constraint minimum variance beamformer functional magnetic resonance inverse imaging
    Lin, Fa-Hsuan
    Witzel, Thomas
    Zeffiro, Thomas A.
    Belliveau, John W.
    NEUROIMAGE, 2008, 43 (02) : 297 - 311