摘要
Background: The acute and long-term effects of transcatheter aortic valve implantation (TAVI) in patients with aortic valve stenosis on left ventricular (LV) function are controversial. The aim of this study was to determine the effect of TAVI on LV function with two-dimensional (2D) and three-dimensional (3D) speckle-tracking analysis of LV deformation capability. Methods: Patients underwent standardized 2D and 3D transthoracic echocardiography before TAVI and after 6 months of follow-up, including 3D and 2D LV deformation imaging. Results: Forty-four patients (mean age, 81.7 +/- 5.5 years; 21 men [47.7%]; mean body mass index, 26.3 +/- 5.1 kg/m(2); mean logistic European System for Cardiac Operative Risk Evaluation score, 24.4 +/- 13.7%)) undergoing TAVI were prospectively included. After follow-up, mean 3D LV ejection fraction (LVEF) (35.4 +/- 13.1% vs 40.6 +/- 12.6%, P = .004), 3D LV volumes (end-systolic volume, 85.9 +/- 41.8 vs 65.9 +/- 33.7 mL, P < .001; end-diastolic volume, 127.6 +/- 40.7 vs 106.4 +/- 40.9 mL, P = .001), 3D global longitudinal strain ( 9.9 +/- 3.7% vs 12.6 +/- 4.2%, P < .001), and 3D LV twist (6.1 +/- 4.3 degrees vs 8.5 +/- 6.9 degrees, P = .025) were relevantly improved. LV improvement was pronounced in patients with decreased baseline LV function (area under the curve, 0.78; P < .001), with a cutoff value for 3D LVEF of <= 37% to identify functional responders to TAVI. After follow-up, patients with 3D LVEFs <= 37% showed a significant improvements in 3D LVEF (26.0 +/- 7.6% vs 35.9 +/- 11.7%, P < .001), 3D LV volumes (end-diastolic volume, 147.4 +/- 40.6 vs 117.1 +/- 45.5 mL, P = .001; end-systolic volume, 110.9 +/- 39.2 vs 77.5 +/- 37.2 mL, P < .001), 3D global longitudinal strain (-7.8 +/- 2.7% vs -11.3 +/- 4.2%, P < .001), and 3D LV twist (5.6 +/- 4.2 degrees vs 8.0 +/- 5.6 degrees, P = .047), whereas in patients with 3D LVEFs > 37%, only 3D global longitudinal strain was relevantly altered (-12.5 +/- 3.1% vs -14.2 +/- 3.8%, P = .04). Compared with 2D transthoracic echocardiography, 3D LV functional imaging allowed significantly faster image acquisition and data analysis (P < .0001). New York Heart Association functional class improved significantly in both groups (3D LVEF <= 37%, from 3.1 +/- 0.5 to 2.0 +/- 0.6, P < .001; 3D LVEF > 37%, from 2.7 +/- 6.7 to 1.5 +/- 0.7, P < .001), whereas a significant amelioration of N-terminal pro-brain natriuretic peptide was observed only inpatients with baseline 3D LVEFs <= 37% (10,314.46 +/- 11,682.2 vs 3,398.7 +/- 3,598.9 pg/mL, P = .02; 3D LVEF > 37%, 10,306.4 +/- 32,000.5 vs 2,868.0 +/- 3,816.7 pg/mL, P = .12). Conclusions: Our results indicate significant improvements of LV global and longitudinal function and clinical parameters 6 months after TAVI that are pronounced in patients with impaired baseline LV function. Compared with 2D LV functional imaging, 3D speckle-tracking imaging allowed significantly faster image acquisition and data analysis. (J Am Soc Echocardiogr 2012;25:827-34.)
引用
收藏
页码:827 / +
页数:9
相关论文
共 50 条
  • [41] Normal Ranges of Left Ventricular Strain by Three-Dimensional Speckle-Tracking Echocardiography in Children: A Meta-Analysis
    Truong, Vien T.
    Phan, Hoang T.
    Ngo, Tam N. M.
    Nguyen, Tuy T. H.
    Ngo, Ha T.
    Tran, Ngoc B.
    Palmer, Cassady
    Alsaied, Tarek
    Tretter, Justin T.
    Levy, Philip T.
    Chung, Eugene S.
    Mazur, Wojciech
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2020, 33 (11) : 1407 - +
  • [42] Evaluation of Right Ventricular Systolic Function after Mitral Valve Repair: A Two-Dimensional Doppler, Speckle-Tracking, and Three-Dimensional Echocardiographic Study
    Maffessanti, Francesco
    Gripari, Paola
    Tamborini, Gloria
    Muratori, Manuela
    Fusini, Laura
    Alamanni, Francesco
    Zanobini, Marco
    Fiorentini, Cesare
    Caiani, Enrico G.
    Pepi, Mauro
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (07) : 701 - 708
  • [43] The impact of type 2 diabetes on left ventricular function in hypertensive patients: a three-dimensional speckle-tracking imaging study
    Yang, Qingmei
    Chen, Xiaoyan
    Fang, Jianxiu
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2025, 11
  • [44] Evaluation of global left ventricular systolic function in patients with heart failure using three-dimensional speckle-tracking echocardiography
    Luo, X. X.
    Fang, F.
    Lee, P. W.
    Li, S.
    Zhang, Z. H.
    Lam, Y. Y.
    Sanderson, J. E.
    Kwong, J. S. W.
    Yu, C. M.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 : S21 - S22
  • [45] Early results of MitraClip system implantation by real-time three-dimensional speckle-tracking left ventricle analysis
    Scandura, Salvatore
    Dipasqua, Fabio
    Gargiulo, Giuseppe
    Capodanno, Davide
    Caggegi, Anna
    Grasso, Carmelo
    Mangiafico, Sarah
    Pistritto, Anna Maria
    Imme, Sebastiano
    Chiaranda, Marta
    Ministeri, Margherita
    Ronsivalle, Giuseppe
    Cannata, Stefano
    Arcidiacono, Antonio Andrea
    Capranzano, Piera
    Tamburino, Corrado
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2016, 17 (11) : 843 - 849
  • [46] Three-Dimensional Echocardiography in Paravalvular Aortic Regurgitation Assessment after Transcatheter Aortic Valve Implantation
    Goncalves, Alexandra
    Almeria, Carlos
    Marcos-Alberca, Pedro
    Feltes, Gisela
    Hernandez-Antolin, Rosana
    Rodriguez, Enrique
    Silva Cardoso, Jose C.
    Macaya, Carlos
    Luis Zamorano, Jose
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (01) : 47 - 55
  • [47] Global and Regional Right Ventricular Function Assessed by Novel Three-Dimensional Speckle-Tracking Echocardiography
    Ishizu, Tomoko
    Seo, Yoshihiro
    Atsumi, Akiko
    Tanaka, Yumiko Oishi
    Yamamoto, Masayoshi
    Machino-Ohtsuka, Tomoko
    Horigome, Hitoshi
    Aonuma, Kazutaka
    Kawakami, Yasushi
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (12) : 1203 - 1213
  • [48] Evaluation of Left Ventricular Function by Three-Dimensional Speckle-Tracking Echocardiography in Patients with Myocardial Bridging of the Left Anterior Descending Coronary Artery
    Wang, Dian
    Sun, Jing Ping
    Lee, Alex Pui-wai
    Ma, Gen Shan
    Yang, Xing Sheng
    Yu, Cheuk-man
    Ding, Jian Dong
    Liu, Nai Feng
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2015, 28 (06) : 674 - 682
  • [49] Three-Dimensional Speckle-Tracking Echocardiographic Assessment of Ventricular Dyssynchrony and Arrhythmic Risk in Mitral Valve Prolapse
    Capotosto, Lidia
    Nguyen, Bich Lien L.
    Tanzilli, Gaetano
    Ciardi, Maria
    Mangieri, Enrico
    Muscaritoli, Maurizio
    Miraldi, Fabio
    Vitarelli, Antonio
    CIRCULATION, 2021, 144
  • [50] The miracle of left ventricular recovery after transcatheter aortic valve implantation
    Dauerman, Harold L.
    Lahoud, Rony
    EUROINTERVENTION, 2024, 20 (08) : E463 - E464