Three-Dimensional Speckle-Tracking Analysis of Left Ventricular Function after Transcatheter Aortic Valve Implantation

被引:61
|
作者
Schueler, Robert [1 ]
Sinning, Jan-Malte [1 ]
Momcilovic, Diana [1 ]
Weber, Marcel [1 ]
Ghanem, Alexander [1 ]
Werner, Nikos [1 ]
Nickenig, Georg [1 ]
Grube, Eberhard [1 ]
Hammerstingl, Christoph [1 ]
机构
[1] Univ Bonn, Dept Internal Med, Bonn, Germany
关键词
TAVI; Three-dimensional speckle-tracking; Strain imaging; Aortic valve stenosis; VALVULAR HEART-DISEASE; EJECTION FRACTION; MAGNETIC-RESONANCE; ECHOCARDIOGRAPHY; STENOSIS; STRAIN; TIME; HYPERTROPHY; REPLACEMENT; GUIDELINES;
D O I
10.1016/j.echo.2012.04.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The acute and long-term effects of transcatheter aortic valve implantation (TAVI) in patients with aortic valve stenosis on left ventricular (LV) function are controversial. The aim of this study was to determine the effect of TAVI on LV function with two-dimensional (2D) and three-dimensional (3D) speckle-tracking analysis of LV deformation capability. Methods: Patients underwent standardized 2D and 3D transthoracic echocardiography before TAVI and after 6 months of follow-up, including 3D and 2D LV deformation imaging. Results: Forty-four patients (mean age, 81.7 +/- 5.5 years; 21 men [47.7%]; mean body mass index, 26.3 +/- 5.1 kg/m(2); mean logistic European System for Cardiac Operative Risk Evaluation score, 24.4 +/- 13.7%)) undergoing TAVI were prospectively included. After follow-up, mean 3D LV ejection fraction (LVEF) (35.4 +/- 13.1% vs 40.6 +/- 12.6%, P = .004), 3D LV volumes (end-systolic volume, 85.9 +/- 41.8 vs 65.9 +/- 33.7 mL, P < .001; end-diastolic volume, 127.6 +/- 40.7 vs 106.4 +/- 40.9 mL, P = .001), 3D global longitudinal strain ( 9.9 +/- 3.7% vs 12.6 +/- 4.2%, P < .001), and 3D LV twist (6.1 +/- 4.3 degrees vs 8.5 +/- 6.9 degrees, P = .025) were relevantly improved. LV improvement was pronounced in patients with decreased baseline LV function (area under the curve, 0.78; P < .001), with a cutoff value for 3D LVEF of <= 37% to identify functional responders to TAVI. After follow-up, patients with 3D LVEFs <= 37% showed a significant improvements in 3D LVEF (26.0 +/- 7.6% vs 35.9 +/- 11.7%, P < .001), 3D LV volumes (end-diastolic volume, 147.4 +/- 40.6 vs 117.1 +/- 45.5 mL, P = .001; end-systolic volume, 110.9 +/- 39.2 vs 77.5 +/- 37.2 mL, P < .001), 3D global longitudinal strain (-7.8 +/- 2.7% vs -11.3 +/- 4.2%, P < .001), and 3D LV twist (5.6 +/- 4.2 degrees vs 8.0 +/- 5.6 degrees, P = .047), whereas in patients with 3D LVEFs > 37%, only 3D global longitudinal strain was relevantly altered (-12.5 +/- 3.1% vs -14.2 +/- 3.8%, P = .04). Compared with 2D transthoracic echocardiography, 3D LV functional imaging allowed significantly faster image acquisition and data analysis (P < .0001). New York Heart Association functional class improved significantly in both groups (3D LVEF <= 37%, from 3.1 +/- 0.5 to 2.0 +/- 0.6, P < .001; 3D LVEF > 37%, from 2.7 +/- 6.7 to 1.5 +/- 0.7, P < .001), whereas a significant amelioration of N-terminal pro-brain natriuretic peptide was observed only inpatients with baseline 3D LVEFs <= 37% (10,314.46 +/- 11,682.2 vs 3,398.7 +/- 3,598.9 pg/mL, P = .02; 3D LVEF > 37%, 10,306.4 +/- 32,000.5 vs 2,868.0 +/- 3,816.7 pg/mL, P = .12). Conclusions: Our results indicate significant improvements of LV global and longitudinal function and clinical parameters 6 months after TAVI that are pronounced in patients with impaired baseline LV function. Compared with 2D LV functional imaging, 3D speckle-tracking imaging allowed significantly faster image acquisition and data analysis. (J Am Soc Echocardiogr 2012;25:827-34.)
引用
收藏
页码:827 / +
页数:9
相关论文
共 50 条
  • [31] Evaluation of Left Ventricular Systolic Function in Patients with Coronary Microvascular Dysfunction by Three-Dimensional Speckle-Tracking Imaging
    Yu, Ziheng
    Pan, Hongfen
    Cheng, Zhenfeng
    Lu, Kongjie
    Hu, Huanhuan
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2022, 37 (03) : 321 - 327
  • [32] Value of three-dimensional speckle-tracking imaging in detecting left ventricular systolic function in patients with dilated cardiomyopathy
    He, Jionghong
    Yang, Long
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (08): : 1492 - 1495
  • [33] Left ventricular recovery after transcatheter aortic valve implantation
    Vavuranakis, M.
    Kariori, MMaria
    Voudris, V.
    Thomopoulou, S.
    Kalogeras, K.
    Stefopoulos, C.
    Aznaouridis, K.
    Moldovan, C.
    Vrachatis, D.
    Stefanadis, C. H.
    EUROPEAN JOURNAL OF HEART FAILURE, 2014, 16 : 330 - 330
  • [34] Relationship between three-dimensional speckle-tracking echocardiography-derived left ventricular rotation and twist and aortic stiffness
    Nemes, A.
    Kalapos, A.
    Domsik, P.
    Lengyel, C.
    Orosz, A.
    Forster, T.
    EUROPEAN HEART JOURNAL, 2012, 33 : 851 - 851
  • [35] Assessment of left atrial function by three-dimensional speckle-tracking in cardiomyopathies: A step forward?
    Ribeiro, Jose
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2017, 36 (12) : 915 - 917
  • [36] Changes in Speckle-Tracking Echocardiography Measures of Ventricular Function After Percutaneous Implantation of the Edwards SAPIEN Transcatheter Heart Valve in the Pulmonary Position
    Chowdhury, Shahryar M.
    Pietris, Nicholas P.
    Hiiazi, Ziyad M.
    Rhodes, John F.
    Kar, Saibal
    Makkar, Raj
    Mullen, Michael
    Cao, Qi-Ling
    Mandinov, Lazar
    Shirali, Girish S.
    CIRCULATION, 2013, 128 (22)
  • [37] Early Recovery of Left Ventricular Systolic Function After Transcatheter Aortic Valve Implantation
    Drakopoulou, Maria
    Soulaidopoulos, Stergios
    Oikonomou, George
    Kouroutzoglou, Alexandrina
    Toskas, Pantelis
    Stathogiannis, Konstantinos
    Xanthopoulou, Maria
    Synetos, Andreas
    Latsios, George
    Papanikolaou, Angelos
    Sideris, Skevos
    Tousoulis, Dimitrios
    Toutouzas, Konstantinos
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B45 - B45
  • [38] Early Recovery of Left Ventricular Systolic Function after Transcatheter Aortic Valve Implantation
    Deste, Wanda
    Gulino, Simona
    Zappulla, Paolo
    Iacono, Federica
    Sicuso, Rita
    Indelicato, Antonino
    Monte, P. Ines
    Rapisarda, Giulia
    Trovato, Danilo
    Cirasa, Arianna
    Sgroi, Carmelo
    Barbanti, Marco
    Tamburino, Corrado
    JOURNAL OF CARDIOVASCULAR ECHOGRAPHY, 2018, 28 (03) : 166 - 170
  • [39] Three-Dimensional Blood Flow Alterations After Transcatheter Aortic Valve Implantation
    Markl, Michael
    Mikati, Issam
    Carr, James
    McCarthy, Patrick
    Malaisrie, S. Chris
    CIRCULATION, 2012, 125 (15) : E573 - E575
  • [40] Three-Dimensional Speckle-Tracking Imaging for Left Ventricular Rotation Measurement An In Vitro Validation Study
    Zhou, Zhiwen
    Ashraf, Muhammad
    Hu, Dayi
    Dai, Xiaonan
    Xu, Yawei
    Kenny, Bill
    Cameron, Berkley
    Nguyen, Thuan
    Xiong, Li
    Sahn, David J.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (06) : 903 - 909