Three-Dimensional Speckle-Tracking Analysis of Left Ventricular Function after Transcatheter Aortic Valve Implantation

被引:61
|
作者
Schueler, Robert [1 ]
Sinning, Jan-Malte [1 ]
Momcilovic, Diana [1 ]
Weber, Marcel [1 ]
Ghanem, Alexander [1 ]
Werner, Nikos [1 ]
Nickenig, Georg [1 ]
Grube, Eberhard [1 ]
Hammerstingl, Christoph [1 ]
机构
[1] Univ Bonn, Dept Internal Med, Bonn, Germany
关键词
TAVI; Three-dimensional speckle-tracking; Strain imaging; Aortic valve stenosis; VALVULAR HEART-DISEASE; EJECTION FRACTION; MAGNETIC-RESONANCE; ECHOCARDIOGRAPHY; STENOSIS; STRAIN; TIME; HYPERTROPHY; REPLACEMENT; GUIDELINES;
D O I
10.1016/j.echo.2012.04.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The acute and long-term effects of transcatheter aortic valve implantation (TAVI) in patients with aortic valve stenosis on left ventricular (LV) function are controversial. The aim of this study was to determine the effect of TAVI on LV function with two-dimensional (2D) and three-dimensional (3D) speckle-tracking analysis of LV deformation capability. Methods: Patients underwent standardized 2D and 3D transthoracic echocardiography before TAVI and after 6 months of follow-up, including 3D and 2D LV deformation imaging. Results: Forty-four patients (mean age, 81.7 +/- 5.5 years; 21 men [47.7%]; mean body mass index, 26.3 +/- 5.1 kg/m(2); mean logistic European System for Cardiac Operative Risk Evaluation score, 24.4 +/- 13.7%)) undergoing TAVI were prospectively included. After follow-up, mean 3D LV ejection fraction (LVEF) (35.4 +/- 13.1% vs 40.6 +/- 12.6%, P = .004), 3D LV volumes (end-systolic volume, 85.9 +/- 41.8 vs 65.9 +/- 33.7 mL, P < .001; end-diastolic volume, 127.6 +/- 40.7 vs 106.4 +/- 40.9 mL, P = .001), 3D global longitudinal strain ( 9.9 +/- 3.7% vs 12.6 +/- 4.2%, P < .001), and 3D LV twist (6.1 +/- 4.3 degrees vs 8.5 +/- 6.9 degrees, P = .025) were relevantly improved. LV improvement was pronounced in patients with decreased baseline LV function (area under the curve, 0.78; P < .001), with a cutoff value for 3D LVEF of <= 37% to identify functional responders to TAVI. After follow-up, patients with 3D LVEFs <= 37% showed a significant improvements in 3D LVEF (26.0 +/- 7.6% vs 35.9 +/- 11.7%, P < .001), 3D LV volumes (end-diastolic volume, 147.4 +/- 40.6 vs 117.1 +/- 45.5 mL, P = .001; end-systolic volume, 110.9 +/- 39.2 vs 77.5 +/- 37.2 mL, P < .001), 3D global longitudinal strain (-7.8 +/- 2.7% vs -11.3 +/- 4.2%, P < .001), and 3D LV twist (5.6 +/- 4.2 degrees vs 8.0 +/- 5.6 degrees, P = .047), whereas in patients with 3D LVEFs > 37%, only 3D global longitudinal strain was relevantly altered (-12.5 +/- 3.1% vs -14.2 +/- 3.8%, P = .04). Compared with 2D transthoracic echocardiography, 3D LV functional imaging allowed significantly faster image acquisition and data analysis (P < .0001). New York Heart Association functional class improved significantly in both groups (3D LVEF <= 37%, from 3.1 +/- 0.5 to 2.0 +/- 0.6, P < .001; 3D LVEF > 37%, from 2.7 +/- 6.7 to 1.5 +/- 0.7, P < .001), whereas a significant amelioration of N-terminal pro-brain natriuretic peptide was observed only inpatients with baseline 3D LVEFs <= 37% (10,314.46 +/- 11,682.2 vs 3,398.7 +/- 3,598.9 pg/mL, P = .02; 3D LVEF > 37%, 10,306.4 +/- 32,000.5 vs 2,868.0 +/- 3,816.7 pg/mL, P = .12). Conclusions: Our results indicate significant improvements of LV global and longitudinal function and clinical parameters 6 months after TAVI that are pronounced in patients with impaired baseline LV function. Compared with 2D LV functional imaging, 3D speckle-tracking imaging allowed significantly faster image acquisition and data analysis. (J Am Soc Echocardiogr 2012;25:827-34.)
引用
收藏
页码:827 / +
页数:9
相关论文
共 50 条
  • [1] THREE-DIMENSIONAL SPECKLE TRACKING IMAGING IN ASSESSMENT OF LEFT VENTRICULAR REGIONAL SYSTOLIC FUNCTION AFTER TRANSCATHETER AORTIC VALVE IMPLANTATION
    Ping, Chen Li
    Hong, Tang
    HEART, 2013, 99 : E233 - E234
  • [2] Improvement of left ventricular longitudinal systolic function after transcatheter aortic valve implantation: a speckle-tracking prospective study
    D'Ascenzi, Flavio
    Cameli, Matteo
    Iadanza, Alessandro
    Lisi, Matteo
    Zaca, Valerio
    Reccia, Rosanna
    Curci, Valeria
    Torrisi, Andrea
    Sinicropi, Giuseppe
    Pierli, Carlo
    Mondillo, Sergio
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05): : 1007 - 1015
  • [3] Improvement of left ventricular longitudinal systolic function after transcatheter aortic valve implantation: a speckle-tracking prospective study
    Flavio D’Ascenzi
    Matteo Cameli
    Alessandro Iadanza
    Matteo Lisi
    Valerio Zacà
    Rosanna Reccia
    Valeria Curci
    Andrea Torrisi
    Giuseppe Sinicropi
    Carlo Pierli
    Sergio Mondillo
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1007 - 1015
  • [4] 3d Speckle Tracking Analysis of Left Ventricular Function after Transcatheter Aortic Valve Implantation
    Hammersting, Christoph
    Schueler, Robert
    Sinning, Jan-Mallte
    Werner, Nikos
    Ghanem, Alexander
    Grube, Eberhardt
    Nickenig, Georg
    CIRCULATION, 2012, 126 (21)
  • [5] Evaluation of left ventricular and atrial function evaluated by two and three-dimensional speckle tracking in patients undergone to transcatheter aortic valve implantation
    Ancona, R.
    Pinto, S. C. P. Comenale
    Caso, P. C.
    Coppola, M. G. C.
    Sellitto, V. S.
    Macrino, M. M.
    Monteforte, I. M.
    Ferro, A.
    Calabro, R. C.
    EUROPEAN HEART JOURNAL, 2016, 37 : 461 - 461
  • [6] 3D speckle tracking analysis of left ventricular function after transcatheter aortic valve implantation
    Hammerstingl, C.
    Schueler, R.
    Sinning, J. M.
    Ghanem, A.
    Momcilovic, D.
    Grube, E.
    Werner, N.
    Nickenig, G.
    EUROPEAN HEART JOURNAL, 2012, 33 : 578 - 578
  • [7] TRANSCATHETER AORTIC VALVE IMPLANTATION IMPROVES LEFT ATRIAL PHASIC FUNCTION BY SPECKLE-TRACKING ECHOCARDIOGRAPHY
    Poulin, Frederic
    Lim, Ki-Dong
    Finn, Heather
    Carasso, Shemy
    Horlick, Eric
    Osten, Mark
    Feindel, Christopher
    Cusimano, Robert J.
    Rakowski, Harry
    Woo, Anna
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1049 - E1049
  • [8] EARLY IMPROVEMENT OF LEFT ATRIAL FUNCTION AND MORPHOLOGY AFTER TRANSCATHETER AORTIC VALVE IMPLANTATION: A SPECKLE-TRACKING LONGITUDINAL STUDY
    D'Ascenzi, Flavio
    Iadanza, Alessandro
    Cameli, Matteo
    Lisi, Matteo
    Sinicropi, Giuseppe
    Reccia, Rosanna
    Curci, Valeria
    Mondillo, Sergio
    Pierli, Carlo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1902 - E1902
  • [9] Using three-dimensional speckle-tracking echocardiography to assess the left ventricular function of varying degrees aortic stenosis
    Wu Ting
    Bai Wenjuan
    Tang Hong
    Rao Li
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (16) : C232 - C232
  • [10] The variation of left ventricular strain after aortic valve replacement by three-dimensional speckle tracking echocardiography
    Cheng, L. L.
    Shu, X. H.
    Chen, Y. L.
    Wang, C. S.
    Ge, J. B.
    EUROPEAN HEART JOURNAL, 2014, 35 : 502 - 503