Influence of mechanical ventilation-shaft connecting location on subway tunnel ventilation performance

被引:25
|
作者
Juraeva, Makhsuda [1 ]
Ryu, Kyung Jin [1 ]
Jeong, Sang-Hyun [2 ]
Song, Dong Joo [1 ]
机构
[1] Yeungnam Univ, Sch Mech Engn, Geyongsan Si 712749, South Korea
[2] Korea Inst Machinery & Mat, Taejon, South Korea
关键词
Air-curtain; Indoor air quality; Guide-vane; Porous zone; Subway tunnel; SIMULATION; FLOW; FAN;
D O I
10.1016/j.jweia.2013.05.016
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Subways are widely used for public transportation in major cities and require efficient ventilation systems to maintain indoor air quality in the subway tunnel. A subway tunnel was investigated to understand the airflow inside the tunnel, and to improve its ventilation system. The steady three-dimensional airflow in the tunnel was analyzed using ANSYS CFX software to solve Reynolds-averaged Navier-Stokes equations. The ventilation performance in the subway tunnel was investigated with respect to the connecting location of the mechanical ventilation shaft by analyzing mass flow rate through the ventilation-shafts and the airflow in the tunnel. The airflow in the tunnel and the mass flow rate in the shafts were investigated when the guide-vane, the porous zone and the air-curtain were installed in the subway tunnel system. The discharged-air was higher at ventilation-shaft 2 which was connected to the top wall of the tunnel than that of the ventilation-shaft 1 which was connected to the side wall of the tunnel. The numerical results suggested the connecting location of shaft 2 as the optimum connecting location. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:114 / 120
页数:7
相关论文
共 50 条
  • [1] Effects of vent shaft location on the ventilation performance in a subway tunnel
    Kim, Jung-Yup
    Kim, Kwang-Yong
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2009, 97 (5-6) : 174 - 179
  • [2] A Numerical Analysis of the Ventilation Performance for Different Ventilation Strategies in a Subway Tunnel
    Yuan-dong Huang
    Chan Li
    Chang Nyung Kim
    Journal of Hydrodynamics, 2012, 24 : 193 - 201
  • [3] A NUMERICAL ANALYSIS OF THE VENTILATION PERFORMANCE FOR DIFFERENT VENTILATION STRATEGIES IN A SUBWAY TUNNEL
    KIM Chang Nyung
    Journal of Hydrodynamics, 2012, 24 (02) : 193 - 201
  • [4] A NUMERICAL ANALYSIS OF THE VENTILATION PERFORMANCE FOR DIFFERENT VENTILATION STRATEGIES IN A SUBWAY TUNNEL
    Huang Yuan-dong
    Li Chan
    Kim, Chang Nyung
    JOURNAL OF HYDRODYNAMICS, 2012, 24 (02) : 193 - 201
  • [5] A Study on Optimization of Middle Vent Shaft in Subway Tunnel Ventilation System
    Lin, Fang
    Zeng, Yanhua
    Zhou, Xiaohan
    He, Jianfeng
    CIVIL, STRUCTURAL AND ENVIRONMENTAL ENGINEERING, PTS 1-4, 2014, 838-841 : 1381 - +
  • [6] Effects of the ventilation duct arrangement and duct geometry on ventilation performance in a subway tunnel
    Huang Yuan-dong
    Gong Xiao-lu
    Peng Yue-jiao
    Lin Xiao-yu
    Chang-Nyung, Kim
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2011, 26 (06) : 725 - 733
  • [7] Effects of the solid curtains on natural ventilation performance in a subway tunnel
    Huang, Yuan-dong
    Gong, Xiao-lu
    Peng, Yue-jiao
    Kim, Chang-Nyung
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2013, 38 : 526 - 533
  • [8] The application of array silencer performance curve in subway tunnel ventilation system
    Hu, Zilin
    Fang, Qingchuan
    Journal of Railway Science and Engineering, 2022, 19 (06) : 1794 - 1800
  • [9] Improvement of shallow subway tunnel ventilation procedures
    N. A. Popov
    A. M. Krasyuk
    I. V. Lugin
    S. A. Pavlov
    D. V. Zedgenizov
    Journal of Mining Science, 2014, 50 : 943 - 952
  • [10] Improvement of shallow subway tunnel ventilation procedures
    Popov, N. A.
    Krasyuk, A. M.
    Lugin, I. V.
    Pavlov, S. A.
    Zedgenizov, D. V.
    JOURNAL OF MINING SCIENCE, 2014, 50 (05) : 943 - 952