Evaluation of a non-invasive bladder volume measurement in children

被引:11
|
作者
Koomen, Erik [1 ]
Bouman, Esther [2 ]
Callewaerdt, Piet [2 ]
Vos, Gijs D. [3 ]
Prins, Martin H. [4 ]
Anderson, Brian J. [5 ]
Marcus, Marco A. E. [6 ]
机构
[1] Sophia Childrens Univ Hosp, Dept Anaesthesia, Rotterdam, Netherlands
[2] Maastricht Univ Hosp, Dept Anaesthesia, Maastricht, Netherlands
[3] Maastricht Univ Hosp, Dept Paediat, Maastricht, Netherlands
[4] Maastricht Univ Hosp, Dept Epidemiol, Maastricht, Netherlands
[5] Univ Maastricht, Dept Anaesthesia, Maastricht, Netherlands
[6] Univ Auckland, Dept Anaesthesia, Auckland 1, New Zealand
来源
关键词
Pediatric; bladder volume; non-invasive measurement; BladderScan;
D O I
10.1080/00365590802054600
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective. Postoperative urinary retention (PUR) is associated with overdistension of the bladder. The prevention of PUR by routine catheterization may increase the risk of urinary tract infection. Postoperative monitoring of the bladder volume by ultrasound to prevent PUR is reliable in adults, but has not been evaluated in children. Material and methods. The BladderScan BVI 6200, an ultrasound device specifically designed for children, was assessed. Forty patients who required urinary catheter placement during surgery or during intensive care unit stay were entered into this blinded calibration study. An assessment of bladder urine volume by ultrasound was performed before and after catheterization in surgical patients. In these patients and intensive care patients 0, 2.5 or 5 ml/kg sterile normal NaCl was injected through the bladder catheter and the catheter was clamped. Volumes estimated with ultrasound were compared with measured catheter drainage or/and injected volume after the scan. Results. The mean relative difference (bias) between the ultrasound estimate and the injected volume was -20% (95% confidence interval 140 to -180%). Precision, estimated using the Wilcoxon signed ranks test, showed a significant difference (Z=-3.25, p=0.001) between the ultrasound-estimated volumes and the injected volumes. Conclusions. This study could not confirm good agreement between the ultrasound-estimated volumes and the injected volumes at volumes below 5 ml/kg. Bladder volumes were underestimated with a very broad 95% confidence interval. The ultrasound device should not replace current clinical assessment.
引用
收藏
页码:444 / 448
页数:5
相关论文
共 50 条
  • [41] Evaluation of the use of non-invasive hemoglobin measurement in early childhood
    Arai, Yoshiteru
    Shoji, Hiromichi
    Awata, Kentaro
    Inage, Eisuke
    Ikuse, Tamaki
    Shimizu, Toshiaki
    PEDIATRIC RESEARCH, 2023, 93 (04) : 1036 - 1040
  • [42] Evaluation of the use of non-invasive hemoglobin measurement in early childhood
    Yoshiteru Arai
    Hiromichi Shoji
    Kentaro Awata
    Eisuke Inage
    Tamaki Ikuse
    Toshiaki Shimizu
    Pediatric Research, 2023, 93 : 1036 - 1040
  • [43] NON-INVASIVE VENTILATORY VOLUME MONITOR
    ITOH, A
    ISHIDA, A
    KIKUCHI, N
    OKAZAKI, N
    ISHIHARA, T
    KIRA, S
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1982, 20 (05) : 613 - 619
  • [44] EVALUATION OF A NON-INVASIVE RESPIRATORY VOLUME MONITOR DURING OBSTRUCTED BREATHING
    Voscopoulos, Christopher
    Freeman, Jenny
    Brayanov, Jordan
    Ladd, Diane
    Lalli, Michael
    MacNabb, C. Marshall
    Eikermann, Matthias
    CRITICAL CARE MEDICINE, 2012, 40 (12) : U35 - U36
  • [45] Review of non-invasive blood pressure measurement in animals: Part 2-Evaluation of the performance of non-invasive devices
    Skelding, Alicia
    Valverde, Alexander
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2020, 61 (05): : 481 - 498
  • [46] ACCURACY OF THREE NON-INVASIVE METHODS FOR BLADDER VOID VOLUME ANALYSIS IN HEALTHY VOLUNTEERS
    Vinod, Naomi
    Nagle, Anna S.
    Naimi, Hameeda A.
    Sheen, Derek
    Kolli, Hiren
    Anele, Uzoma A.
    Klausner, Adam P.
    Speich, John E.
    NEUROUROLOGY AND URODYNAMICS, 2018, 37 : S544 - S545
  • [47] NON-INVASIVE TECHNIQUE FOR EVALUATION OF CARDIAC FUNCTION IN INFANTS AND CHILDREN
    HERNANDE.A
    OKAMOTO, GA
    GOLDRING, D
    KLINT, RB
    PEDIATRIC RESEARCH, 1972, 6 (04) : 345 - &
  • [48] MECHANOGRAPHY - NON-INVASIVE TECHNIQUE FOR EVALUATION OF CARDIAC FUNCTION IN CHILDREN
    SPITAELS, S
    DAVIGNON, A
    FOURON, JC
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1972, 107 (11) : 1096 - &
  • [49] Polysomnographic evaluation of non-invasive ventilation in children with neuromuscular disease
    Falsaperla, Raffaele
    Wenzel, Anette
    Pavone, Piero
    Di Mauro, Caterina
    Vitaliti, Giovanna
    RESPIROLOGY, 2014, 19 (01) : 80 - 84
  • [50] NON-INVASIVE TESTS IN THE INITIAL EVALUATION OF HEART MURMURS IN CHILDREN
    NEWBURGER, JW
    ROSENTHAL, A
    WILLIAMS, RG
    FELLOWS, K
    MIETTINEN, OS
    NEW ENGLAND JOURNAL OF MEDICINE, 1983, 308 (02): : 61 - 64