Evaluation of a non-invasive bladder volume measurement in children

被引:11
|
作者
Koomen, Erik [1 ]
Bouman, Esther [2 ]
Callewaerdt, Piet [2 ]
Vos, Gijs D. [3 ]
Prins, Martin H. [4 ]
Anderson, Brian J. [5 ]
Marcus, Marco A. E. [6 ]
机构
[1] Sophia Childrens Univ Hosp, Dept Anaesthesia, Rotterdam, Netherlands
[2] Maastricht Univ Hosp, Dept Anaesthesia, Maastricht, Netherlands
[3] Maastricht Univ Hosp, Dept Paediat, Maastricht, Netherlands
[4] Maastricht Univ Hosp, Dept Epidemiol, Maastricht, Netherlands
[5] Univ Maastricht, Dept Anaesthesia, Maastricht, Netherlands
[6] Univ Auckland, Dept Anaesthesia, Auckland 1, New Zealand
来源
关键词
Pediatric; bladder volume; non-invasive measurement; BladderScan;
D O I
10.1080/00365590802054600
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective. Postoperative urinary retention (PUR) is associated with overdistension of the bladder. The prevention of PUR by routine catheterization may increase the risk of urinary tract infection. Postoperative monitoring of the bladder volume by ultrasound to prevent PUR is reliable in adults, but has not been evaluated in children. Material and methods. The BladderScan BVI 6200, an ultrasound device specifically designed for children, was assessed. Forty patients who required urinary catheter placement during surgery or during intensive care unit stay were entered into this blinded calibration study. An assessment of bladder urine volume by ultrasound was performed before and after catheterization in surgical patients. In these patients and intensive care patients 0, 2.5 or 5 ml/kg sterile normal NaCl was injected through the bladder catheter and the catheter was clamped. Volumes estimated with ultrasound were compared with measured catheter drainage or/and injected volume after the scan. Results. The mean relative difference (bias) between the ultrasound estimate and the injected volume was -20% (95% confidence interval 140 to -180%). Precision, estimated using the Wilcoxon signed ranks test, showed a significant difference (Z=-3.25, p=0.001) between the ultrasound-estimated volumes and the injected volumes. Conclusions. This study could not confirm good agreement between the ultrasound-estimated volumes and the injected volumes at volumes below 5 ml/kg. Bladder volumes were underestimated with a very broad 95% confidence interval. The ultrasound device should not replace current clinical assessment.
引用
收藏
页码:444 / 448
页数:5
相关论文
共 50 条
  • [31] Non-invasive Measurement of Respiratory Rate in Children Using the Photoplethysmogram
    Fleming, Susannah
    Tarassenko, Lionel
    Thompson, Matthew
    Mant, David
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1886 - +
  • [32] Suitability of the forearm for non-invasive blood pressure measurement in children
    Greaney, David
    Nakhjavani, Solmaz
    Desmond, Fiona
    Tormey, Mark
    Dawkins, Ian
    O'Hare, Brendan
    PEDIATRIC ANESTHESIA, 2017, 27 (11) : 1125 - 1130
  • [33] Limitations and opportunities of non-invasive liver stiffness measurement in children
    Guido Engelmann
    Jasmin Quader
    Ulrike Teufel
    Jens Peter Schenk
    World Journal of Hepatology, 2017, (08) : 409 - 417
  • [34] Non-invasive detection of bladder cancer
    Pacchioni, Giulia
    NATURE REVIEWS MATERIALS, 2022, 7 (09) : 679 - 679
  • [35] Non-invasive detection of bladder cancer
    Giulia Pacchioni
    Nature Reviews Materials, 2022, 7 : 679 - 679
  • [36] Non-invasive bladder volume measurement for the prevention of postoperative urinary retention: validation of two ultrasound devices in a clinical setting
    Brouwer, Tammo A.
    van den Boogaard, Charina
    van Roon, Eric N.
    Kalkman, Cor J.
    Veeger, Nic
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (06) : 1117 - 1126
  • [37] Non-invasive bladder volume measurement for the prevention of postoperative urinary retention: validation of two ultrasound devices in a clinical setting
    Tammo A. Brouwer
    Charina van den Boogaard
    Eric N. van Roon
    Cor J. Kalkman
    Nic Veeger
    Journal of Clinical Monitoring and Computing, 2018, 32 : 1117 - 1126
  • [38] NON-INVASIVE MEASUREMENT OF MATURITY
    ROCHE, AF
    TYLESHEVSKI, F
    ROGERS, E
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1983, 60 (02) : 246 - 246
  • [39] Immunohistochemical evaluation of angiogenic activity in non-invasive (pTa) bladder cancer
    Ristic-Petrovic, A.
    Stojnev, S.
    Stokanovic, D.
    Krstic, M.
    Velickov, A.
    Kostic, J.
    Velickovic, L. Jankovic
    VIRCHOWS ARCHIV, 2017, 471 : S266 - S266
  • [40] Non-Invasive Measurement of Stress
    Yildiz, Sedat
    ACTA PHYSIOLOGICA, 2015, 215 : 12 - 13