The value of spectral imaging to reduce artefacts in the body after 125I seed implantation

被引:1
|
作者
Liu, Jingang [1 ]
Wang, Wenjuan [2 ]
Zhao, Xingsheng [1 ]
Shen, Zhen [1 ]
Shao, Weiguang [1 ]
Wang, Xizhen [1 ]
Li, Lixin [1 ]
Wang, Bin [1 ,3 ]
机构
[1] Weifang Med Univ, Imaging Ctr, Affiliated Hosp, Weifang 261031, Peoples R China
[2] Weifang Peoples Hosp, Dept Radiol, Weifang, Peoples R China
[3] Binzhou Med Univ, Dept Med Imaging, Med Imaging Res Inst, Yantai, Peoples R China
基金
中国国家自然科学基金;
关键词
iodine radioisotope; metal artefact; spectral CT imaging; CELL LUNG-CANCER; DUAL-ENERGY CT; METAL ARTIFACTS; HIP PROSTHESES; SOFTWARE; CHEMOTHERAPY; METASTASES;
D O I
10.1111/1754-9485.12504
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: To explore the value of gemstone spectral imaging ( GSI) and metal artefact reduction sequence ( MARs) to reduce the artefacts of metal seeds. Methods: Thirty-five patients with I-125 seed implantation in their abdomens underwent GSI CT. Six types of monochromatic images and the corresponding MARs images at 60-110 keV ( interval of 10 keV) were reconstructed. The differences in the quality of the images of three imaging methods were subjectively assessed by three radiologists. Length of artefacts, the CT value and noise value of tissue adjacent to I-125 seeds, contrast-to-noise ratio ( CNR), and artefact index ( AI) were recorded. Results: The differences in subjective scoring were statistically significant ( t = 10.87, P < 0.001). Images at 70 keV showed the best CNR ( 0.84 +/- 0.17) of tissues adjacent to I-125 seeds, and received the highest subjective score ( 2.82 +/- 0.18). Images at 80 keV had the lowest AI ( 70.67 +/- 19.17). Images at 110 keV had the shortest artefact lengths. High-density metal artefacts in the MARs spectral images were reduced. The length of metal artefacts in images at 110 keV was shorter than that of the polychromatic images and MARs spectral images ( t = 3.35, 3.89, P < 0.05). The difference in CNR between MARs spectral images and polychromatic images, and images at 70 keV was statistically significant ( t = 3.57, 4.16, P < 0.01). Conclusions: Gemstone spectral imaging technique can reduce metal artefacts of I-125 seeds effectively in CT images, and improve the quality of images, and improve the display of tissues adjacent to I-125 seeds after implantation. MARs technique cannot reduce the artefacts caused by radioactive seeds effectively.
引用
收藏
页码:643 / 649
页数:7
相关论文
共 50 条
  • [41] Efficacy of Sorafenib Combining with Radioactive Seed 125I Implantation in Patients with Pulmonary Metastatic Hepatocellular Carcinoma after Liver Transplantation
    Chen, Yinghua
    Luo, Wenhui
    Ma, Yi
    Zhu, Xiaofeng
    He, Xiaoshun
    TRANSPLANTATION, 2015, 99 : 222 - 222
  • [42] The application of a three-dimensional visualized seed planning and navigation system in 125I seed implantation for pancreatic cancer
    Hu, Yanyan
    Qi, Erpeng
    Liu, Fangyi
    Lu, Yuhan
    Tan, Shuilian
    Sun, Ya
    Han, Zhiyu
    Liang, Ping
    Yu, Xiaoling
    ONCOTARGETS AND THERAPY, 2018, 11 : 619 - 627
  • [43] Development of production technology of 125I seed for brachytherapy
    Han, Hyon-Soo
    Park, Ul-Jae
    Son, Kwang-Jae
    Lee, Jun-Sig
    Hong, Soon-Bog
    Nam, Sung-Soo
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2007, 50 (5-6): : 321 - 322
  • [44] Acute urinary morbidity after a permanent 125I implantation for localized prostate cancer
    Ohga, Saiji
    Nakamura, Katsumasa
    Shioyama, Yoshiyuki
    Tatsugami, Katsunori
    Sasaki, Tomonari
    Nonoshita, Takeshi
    Yoshitake, Tadamasa
    Asai, Kaori
    Hirata, Hideki
    Naito, Seiji
    Honda, Hiroshi
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (06) : 1178 - 1183
  • [45] Objective automated assessment of time trends in prostate edema after 125I implantation
    Westendorp, Hendrik
    Kattevilder, Rob
    van 't Riet, Arie
    Minken, Andre W.
    Nuver, Tonnis T.
    Immerzeel, Jos J.
    Hoekstra, Carel J.
    BRACHYTHERAPY, 2012, 11 (05) : 327 - 333
  • [46] Efficacy and dosimetry of 125I seeds implantation for recurrent cervical cancer after radiotherapy
    Qu, A.
    Wang, J.
    Sun, H.
    Jiang, W.
    Jiang, Y.
    Tian, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1227 - S1227
  • [47] Computed Tomography-guided 125I Radioactive Seed Implantation Therapy for Pancreatic Cancer Pain
    Fan, Tao
    Zhou, Ju-Ying
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2020, 30 (04): : 364 - 368
  • [48] Clinical efficacy of 125I seed implantation in the treatment of delayed hepatic metastasis from colon carcinoma
    何津
    ChinaMedicalAbstracts(InternalMedicine), 2016, 33 (02) : 47 - 47
  • [49] Radioactive 125I seed implantation for locally advanced pancreatic cancer: A retrospective analysis of 50 cases
    Cheng-Gang Li
    Zhi-Peng Zhou
    Yu-Ze Jia
    Xiang-Long Tan
    Yu-Yao Song
    World Journal of Clinical Cases, 2020, (17) : 3743 - 3750
  • [50] Lobaplatin-TACE Combined with Radioactive 125I Seed Implantation for Treatment of Primary Hepatocellular Carcinoma
    Peng, Sheng
    Yang, Qiu-Xia
    Zhang, Tao
    Lu, Ming-Jian
    Yang, Guang
    Liu, Zhen-Yin
    Zhang, Rong
    Zhang, Fu-Jun
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (13) : 5155 - 5160