The value of spectral imaging to reduce artefacts in the body after 125I seed implantation

被引:1
|
作者
Liu, Jingang [1 ]
Wang, Wenjuan [2 ]
Zhao, Xingsheng [1 ]
Shen, Zhen [1 ]
Shao, Weiguang [1 ]
Wang, Xizhen [1 ]
Li, Lixin [1 ]
Wang, Bin [1 ,3 ]
机构
[1] Weifang Med Univ, Imaging Ctr, Affiliated Hosp, Weifang 261031, Peoples R China
[2] Weifang Peoples Hosp, Dept Radiol, Weifang, Peoples R China
[3] Binzhou Med Univ, Dept Med Imaging, Med Imaging Res Inst, Yantai, Peoples R China
基金
中国国家自然科学基金;
关键词
iodine radioisotope; metal artefact; spectral CT imaging; CELL LUNG-CANCER; DUAL-ENERGY CT; METAL ARTIFACTS; HIP PROSTHESES; SOFTWARE; CHEMOTHERAPY; METASTASES;
D O I
10.1111/1754-9485.12504
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: To explore the value of gemstone spectral imaging ( GSI) and metal artefact reduction sequence ( MARs) to reduce the artefacts of metal seeds. Methods: Thirty-five patients with I-125 seed implantation in their abdomens underwent GSI CT. Six types of monochromatic images and the corresponding MARs images at 60-110 keV ( interval of 10 keV) were reconstructed. The differences in the quality of the images of three imaging methods were subjectively assessed by three radiologists. Length of artefacts, the CT value and noise value of tissue adjacent to I-125 seeds, contrast-to-noise ratio ( CNR), and artefact index ( AI) were recorded. Results: The differences in subjective scoring were statistically significant ( t = 10.87, P < 0.001). Images at 70 keV showed the best CNR ( 0.84 +/- 0.17) of tissues adjacent to I-125 seeds, and received the highest subjective score ( 2.82 +/- 0.18). Images at 80 keV had the lowest AI ( 70.67 +/- 19.17). Images at 110 keV had the shortest artefact lengths. High-density metal artefacts in the MARs spectral images were reduced. The length of metal artefacts in images at 110 keV was shorter than that of the polychromatic images and MARs spectral images ( t = 3.35, 3.89, P < 0.05). The difference in CNR between MARs spectral images and polychromatic images, and images at 70 keV was statistically significant ( t = 3.57, 4.16, P < 0.01). Conclusions: Gemstone spectral imaging technique can reduce metal artefacts of I-125 seeds effectively in CT images, and improve the quality of images, and improve the display of tissues adjacent to I-125 seeds after implantation. MARs technique cannot reduce the artefacts caused by radioactive seeds effectively.
引用
收藏
页码:643 / 649
页数:7
相关论文
共 50 条
  • [31] Influence of prostate volume on dosimetry results in real-time 125I seed implantation
    McNeely, LK
    Stone, NN
    Presser, J
    Chircus, JH
    Stock, RG
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (01): : 292 - 299
  • [32] Status and prospects of percutaneous vertebroplasty combined with 125I seed implantation for the treatment of spinal metastases
    Xie, Lin
    Chen, Yanjin
    Zhang, Ya
    Yang, Zuozhang
    Zhang, Zhaoxin
    Shen, Lida
    Yuan, Zhongqin
    Ren, Mingyan
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2015, 13
  • [33] Metastatic malignant melanoma: computed tomography-guided 125I seed implantation treatment
    Shi, Feng
    Zhang, Xiaoshi
    Wu, Ketong
    Gao, Fei
    Ding, Ya
    Maharjan, Rakesh
    Zhang, Rong
    Zhang, Fujun
    Li, Chuanxing
    MELANOMA RESEARCH, 2014, 24 (02) : 137 - 143
  • [34] Percutaneous biliary metallic stenting and 125I seed implantation for the treatment of malignant obstructive jaundice
    Wang, Song
    Yu, Chunpeng
    Zhu, Jiafeng
    BIOMEDICAL RESEARCH-INDIA, 2014, 25 (04): : 511 - 514
  • [35] Status and prospects of percutaneous vertebroplasty combined with 125I seed implantation for the treatment of spinal metastases
    Lin Xie
    Yanjin Chen
    Ya Zhang
    Zuozhang Yang
    Zhaoxin Zhang
    Lida Shen
    Zhongqin Yuan
    Mingyan Ren
    World Journal of Surgical Oncology, 13
  • [36] Needle position during 125I seed implantation: accurately recognized by sagittal transrectal ultrasonography?
    Hiromichi Ishiyama
    Shouko Kotani
    Takefumi Satoh
    Mineko Uemae
    Shiro Baba
    Kazushige Hayakawa
    Radiation Medicine, 2008, 26 (10): : 636 - 636
  • [37] Needle position during 125I seed implantation: accurately recognized by sagittal transrectal ultrasonography
    Ishiyama, Hiromichi
    Kotani, Shouko
    Satoh, Takefumi
    Uemae, Mineko
    Baba, Shiro
    Hayakawa, Kazushige
    RADIATION MEDICINE, 2008, 26 (08): : 512 - 515
  • [38] Needle position during 125I seed implantation: accurately recognized by sagittal transrectal ultrasonography
    Hiromichi Ishiyama
    Shouko Kotani
    Takefumi Satoh
    Mineko Uemae
    Shiro Baba
    Kazushige Hayakawa
    Radiation Medicine, 2008, 26 : 512 - 515
  • [39] A Population-based Statistical Model for Investigating Heterogeneous Intraprostatic Sensitivity to Radiation Toxicity After 125I Seed Implantation
    Kobayashi, Kazuma
    Murakami, Naoya
    Takahashi, Kana
    Inaba, Koji
    Igaki, Hiroshi
    Hamamoto, Ryuji
    Itami, Jun
    IN VIVO, 2019, 33 (06): : 2103 - 2111
  • [40] Analysis of postoperative PSA changes after ultrasound-guided permanent [125I] seed implantation for the treatment of prostate cancer
    Bian, X. L.
    Wang, C. Z.
    Wang, Y.
    Li, Y. N.
    Zhang, L. Z.
    Liu, L.
    GENETICS AND MOLECULAR RESEARCH, 2015, 14 (02): : 7142 - 7150